Variability in the analysis of 25-hydroxyvitamin D by liquid chromatography-tandem mass spectrometry: The devil is in the detail

被引:52
|
作者
Couchman, Lewis [1 ]
Benton, Christopher M. [1 ]
Moniz, Cajetan F. [1 ]
机构
[1] Kings Coll Hosp NHS Fdn Trust, Dept Clin Biochem, London SE5 9RS, England
关键词
25-Hydroxyvitamin D; LC-MS/MS; Standardisation; DEQAS; VITAMIN-D STATUS; CIRCULATING; 25-HYDROXYVITAMIN-D; SAMPLE PREPARATION; LC-MS/MS; D ASSAYS; ACCURACY; SERUM; BIOANALYSIS; METABOLITES; INFANTS;
D O I
10.1016/j.cca.2012.04.003
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Liquid chromatography-tandem mass spectrometry (LC-MS/MS) is increasingly used in clinical laboratories for the analysis of 25-hydroxyvitamin D (25OHD), but measurement is not straightforward. Importantly. LC-MS/MS is not a single technique: variables in sample preparation, chromatography and ionisation/fragmentation should each be considered. Methods: We analysed results from a survey organised by the international Vitamin D External Quality Assessment Scheme (DEQAS), to determine the influence of such variables on the results for two DEQAS distributions. Results: 65 laboratories returned questionnaires. 346 (57%) individual results were from laboratories using electrospray ionisation (ESI), and 259 (43%) from laboratories using atmospheric pressure chemical ionisation (APCI). Although the mean ratio of results was not significantly different between ESI and APCI (P = 0.5828), there was greater variation (P<0.0001) in results obtained by laboratories using ESI. Greater variation (P<0.05) was also observed between results from laboratories monitoring non-specific water-loss transitions. Only 3 laboratories (5%) could resolve the isobaric metabolite 3-epi-25OHD(3) from 25OHD(3). Conclusions: There are many variables to consider when using LC-MS/MS, including assay standardisation/calibration, chromatography and MS conditions. MS/MS alone cannot distinguish isobaric metabolites such as 3-epi-25OHD(3). Interference can also occur if non-specific transitions are used. Laboratories should always subscribe to an EQA scheme for 25OHD analysis. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:1239 / 1243
页数:5
相关论文
共 50 条
  • [1] Quantification of circulating 25-hydroxyvitamin D by liquid chromatography-tandem mass spectrometry
    Vogeser, Michael
    JOURNAL OF STEROID BIOCHEMISTRY AND MOLECULAR BIOLOGY, 2010, 121 (3-5): : 565 - 573
  • [2] Quantification of vitamin D and 25-hydroxyvitamin D in soft tissues by liquid chromatography-tandem mass spectrometry
    Lipkie, Tristan E.
    Janasch, Amber
    Cooper, Bruce R.
    Hohman, Emily E.
    Weaver, Connie M.
    Ferruzzi, Mario G.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2013, 932 : 6 - 11
  • [3] Comparison of Automated Immunoassay and Liquid Chromatography Tandem Mass Spectrometry for 25-Hydroxyvitamin D
    Parajuli, S.
    Bhattacharyya, S.
    Hotchandani, N.
    Khan, A.
    Goldsmith, B. M.
    MODERN PATHOLOGY, 2014, 27 : 527A - 527A
  • [4] Comparison of Automated Immunoassay and Liquid Chromatography Tandem Mass Spectrometry for 25-Hydroxyvitamin D
    Parajuli, S.
    Bhattacharyya, S.
    Hotchandani, N.
    Khan, A.
    Goldsmith, B. M.
    LABORATORY INVESTIGATION, 2014, 94 : 527A - 527A
  • [5] Candidate reference method for the quantification of circulating 25-hydroxyvitamin D3 by liquid chromatography-tandem mass spectrometry
    Vogeser, M
    Kyriatsoulis, A
    Huber, E
    Kobold, U
    CLINICAL CHEMISTRY, 2004, 50 (08) : 1415 - 1417
  • [6] RAPID QUANTITATION OF SERUM 25-HYDROXYVITAMIN D3 AND D2 BY LIQUID CHROMATOGRAPHY-TANDEM MASS SPECTROMETRY
    Healy, M.
    Cox, G.
    Casey, M.
    Walsh, J. Bernard
    Laird, E.
    Crowley, V.
    OSTEOPOROSIS INTERNATIONAL, 2010, 21 : S507 - S508
  • [7] Measurement of 25-hydroxyvitamin D by the nichols ADVANTAGE, DiaSorin LIAISON, DiaSorin RIA, and liquid chromatography-tandem mass spectrometry
    Terry, AH
    Sandrock, T
    Meikle, AW
    CLINICAL CHEMISTRY, 2005, 51 (08) : 1565 - 1566
  • [8] Assessment of endogenous 25-hydroxyvitamin D serum concentrations by liquid chromatography-tandem mass spectrometry in various animal species
    Fritz, Carol A.
    Navetta, Kimberly A.
    Wolford, David P.
    Colangelo, Jennifer L.
    VETERINARY CLINICAL PATHOLOGY, 2017, 46 (02) : 371 - 379
  • [9] Determination of 25-hydroxyvitamin D in human plasma using high-performance liquid chromatography-tandem mass spectrometry
    Tsugawa, N
    Suhara, Y
    Kamao, M
    Okano, T
    ANALYTICAL CHEMISTRY, 2005, 77 (09) : 3001 - 3007
  • [10] Accuracy and clinical implications of seven 25-hydroxyvitamin D methods compared with liquid chromatography-tandem mass spectrometry as a reference
    Roth, Heinz Juergen
    Schmidt-Gayk, Heinrich
    Weber, Holger
    Niederau, Christoph
    ANNALS OF CLINICAL BIOCHEMISTRY, 2008, 45 : 153 - 159