Relative sensor registration with two-step method for state estimation

被引:2
|
作者
Ge, Quanbo [1 ,2 ]
Chen, Tianxiang [2 ]
Duan, Zhansheng [3 ]
Liu, Mingxin [4 ]
Niu, Zhuyun [5 ]
机构
[1] Guangdong Ocean Univ, Shenzhen Inst, Shenzhen, Peoples R China
[2] Hangzhou Dianzi Univ, Sch Automat, Inst Syst Sci & Control Engn, Hangzhou, Peoples R China
[3] Xi An Jiao Tong Univ, Ctr Informat Engn Sci Res, Xian, Peoples R China
[4] Yanshan Univ, Coll Informat Sci & Engn, Hebei, Peoples R China
[5] North Automat Control Technol Inst, Taiyuan, Peoples R China
基金
中国国家自然科学基金;
关键词
nonlinear filters; state estimation; Kalman filters; sensor fusion; matrix algebra; linearisation techniques; relative sensor registration problem; global sensor; local sensor; attitude bias; two-step method; location bias; multiplatform multisensor observation system; systematic bias; measurement bias estimation; rotation matrix; unit quaternion method; linear least square algorithm; ALGORITHM;
D O I
10.1049/ccs.2018.0006
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
State estimation suffers from some new challenging problems with a multi-platform multi-sensor observation system. An important problem for multisensor integration is that the data from the local sensors needs to be transformed into a common reference frame free of systematic bias or registration. In this study, the relative sensor registration problem is discussed. It aligns measurement from the global sensor with the local sensor under the assumptions that the global sensor is bias free and all biases reside with the local sensor. The traditional methods failed in the condition when attitude bias becomes large because the error caused by linearisation of rotation matrix increases with growing attitude bias. Motivated by this, a two-step method is established. By estimating the measurement bias through augmented extended Kalman filter in local sensor coordinate independent of attitude and location bias, and by introducing the unit quaternion method compute the attitude and location bias, the proposed method can avoid the problem the traditional methods faced. Simulation examples are provided to verify the proposed method by comparing with the existing linear least square algorithm.
引用
收藏
页码:45 / 54
页数:10
相关论文
共 50 条
  • [41] A Two-Step Cascade Classification Method
    Silva, Eunelson J.
    Britto, Alceu S., Jr.
    Oliveira, Luiz. S.
    Enembreck, Fabricio
    Sabourin, Robert
    Koerich, Alessandro L.
    2017 INTERNATIONAL JOINT CONFERENCE ON NEURAL NETWORKS (IJCNN), 2017, : 573 - 580
  • [42] A two-step method to make microglia
    Bray, Natasha
    NATURE REVIEWS NEUROSCIENCE, 2017, 18 (05) : 264 - 264
  • [43] A two-step grid redistribution method
    Tang, L
    Baeder, JD
    COMPUTERS & FLUIDS, 2003, 32 (03) : 323 - 336
  • [44] A two-step method to make microglia
    Natasha Bray
    Nature Reviews Neuroscience, 2017, 18 : 264 - 264
  • [45] Fast deconvolution by a two-step method
    Barone, P
    SIAM JOURNAL ON SCIENTIFIC COMPUTING, 1999, 21 (03): : 883 - 899
  • [46] Two-step control grading method
    Zhou Yao-lie
    Shao Dan
    Journal of Zhejiang University-SCIENCE A, 2001, 2 (4): : 471 - 475
  • [47] Shooting by a Two-Step Galerkin Method
    Bizzarri, Federico
    Brambilla, Angelo
    Codecasa, Lorenzo
    IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS I-REGULAR PAPERS, 2019, 66 (01) : 383 - 390
  • [48] Fast deconvolution by a two-step method
    Ist. Applicazioni Calcolo M. Picone, Viale del Policlinico 137, 00165 Roma, Italy
    Siam J. Sci. Comput., 3 (883-899):
  • [49] A Novel Two-Step Registration Method for Remote Sensing Images Based on Deep and Local Features
    Ma, Wenping
    Zhang, Jun
    Wu, Yue
    Jiao, Licheng
    Zhu, Hao
    Zhao, Wei
    IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2019, 57 (07): : 4834 - 4843
  • [50] A two-step framework for the registration of HE stained and FTIR images
    Penaranda, Francisco
    Naranjo, Valery
    Verdu, Rafael
    Lloyd, Gavin R.
    Nallala, Jayakrupakar
    Stone, Nick
    OPTICAL BIOPSY XIV: TOWARD REAL-TIME SPECTROSCOPIC IMAGING AND DIAGNOSIS, 2016, 9703