Vectorization of human pelvis objects in X-ray images

被引:0
|
作者
Juozapavicius, Algimantas [1 ]
Markauskas, Ramunas [1 ]
机构
[1] Vilnius State Univ, Fac Math & Informat, LT-03225 Vilnius, Lithuania
来源
关键词
Hough transform; human pelvis; biomechanical parameters; DIAGNOSTIC-RADIOLOGY; HOUGH TRANSFORM;
D O I
10.15388/NA.16.2.14103
中图分类号
O29 [应用数学];
学科分类号
070104 ;
摘要
In medical diagnostics visual evaluation of an object or its image is necessary but time consuming operation. Well-known computer vision algorithms or their compilation, or even some new methods should be the right tool in increasing the speed and reliability of this process. This paper introduces situation in this domain and some experiments and their results in extraction of biomechanical parameters of human pelvis from x-ray images using combination of Hough transform for a line, for a circle (arc) and Canny edge detector. The main idea of an algorithm, which was created during this experiment, is to use different levels of noise filter thus making a balance between leaving too much noise and removing too much actual data. The basic steps would be: filter out most of noise and noisy objects using high filter's threshold value; find sharp and clear objects; narrow the set of possible parameters of noisy objects; apply noise filter with lower threshold value to the original image; find noisy objects. Experiment shows that algorithm works but it needs to be tested on reliability and some bindings with actual biomechanical parameters should be done (see [1-6]).
引用
收藏
页码:170 / 180
页数:11
相关论文
共 50 条
  • [21] A simulator for X-ray images
    Fanti, V
    Marzeddu, R
    Massazza, G
    Randaccio, P
    Brunetti, A
    Golosio, B
    RADIATION PROTECTION DOSIMETRY, 2005, 114 (1-3) : 350 - 354
  • [22] The Iconology of X-Ray Images
    Luczak, Dorota
    SZTUKA I DOKUMENTACJA-ART & DOCUMENTATION, 2016, (14): : 38 - +
  • [23] X-RAY IMAGES AND IMAGERY
    SCHECHTER, DC
    DISEASES OF THE CHEST, 1968, 54 (06): : 488 - +
  • [24] X-RAY PHOTOGRAPHY OF MOVING OBJECTS
    RECOURT, A
    FEDDEMA, J
    MONTE, GLA
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NUKLEARMEDIZIN, 1968, : 24 - &
  • [25] X-RAY TOMOGRAPHY FOR MICROSTRUCTURAL OBJECTS
    SATO, T
    IKEDA, O
    YAMAKOSHI, Y
    TSUBOUCHI, M
    APPLIED OPTICS, 1981, 20 (22): : 3880 - 3883
  • [26] TEST OBJECTS FOR X-RAY TELEVISION
    COLEMAN, NJ
    BRITISH JOURNAL OF RADIOLOGY, 1978, 51 (602): : 145 - 145
  • [27] USE OF X-RAY TEST OBJECTS
    COLEMAN, NJ
    PHYSICS IN MEDICINE AND BIOLOGY, 1978, 23 (01): : 180 - 180
  • [28] X-ray lathe: An x-ray lithographic exposure tool for nonplanar objects
    Feinerman, AD
    Lajos, RE
    Denton, DD
    JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 1996, 5 (04) : 250 - 255
  • [29] Automatic human identification based on dental X-ray images
    Zhou, JD
    Abdel-Mottaleb, M
    BIOMETRIC TECHNOLOGY FOR HUMAN IDENTIFICATION, 2004, 5404 : 373 - 380
  • [30] IMPORTANCE OF PUEUMOPELVIGRAPHY IN X-RAY DIAGNOSIS OF FEMALE PELVIS
    BUBLITZ, G
    RADIOLOGIA DIAGNOSTICA, 1966, 7 (04) : 473 - &