Comparative study of hybrid ground source heat pump in cooling and heating dominant climates

被引:22
|
作者
Bina, Saeid Mohammadzadeh [1 ]
Fujii, Hikari [1 ]
Tsuya, Shunsuke [1 ]
Kosukegawa, Hiroyuki [1 ]
机构
[1] Akita Univ, Grad Sch Engn & Resource Sci, Akita, Japan
关键词
GSHP; Hybrid system; Heat pump; GHE; TRNSYS; Long-term; UNDERGROUND THERMAL IMBALANCE; PERFORMANCE; SYSTEM; FEASIBILITY; EXCHANGERS; GSHP;
D O I
10.1016/j.enconman.2021.115122
中图分类号
O414.1 [热力学];
学科分类号
摘要
The ground source heat pump system (GSHP) has been an accepted technology to provide energy efficient and renewable air conditioning to the buildings. However, imbalanced heating and cooling load during the winter and summers especially in the regions with heating and cooling dominant climates may degrade the performance of the system over a long-term operation. Hybrid GSHP system which uses supplemental energy sources such as solar panel or cooling tower can balance the imposing load on the ground heat exchanger (GHE) and benefits the system by minimizing the GHE length in short-term and improves the overall performance in long-term. This research presents a study of application of hybrid GSHP system with an intention to compare its applicability in the regions with dominant heating and cooling loads. In this study, a student office and an actual heat pump system in Akita City, northern Japan was modeled in TRNSYS software and was validated using in-situ measured data. The hybrid system which coupled with a supplemental heating and cooling source devices was simulated to test its viability for the different heating and cooling loads in different regions within the country. The results revealed that hybrid system plays an effective role in both climates to balance the load on GHE, keeps constant the soil temperature, and consequently improves the long-term performance. Moreover, in short-term, it can reduce the GHE length and decrease drilling cost based on the meteoroidal condition of the region such as solar radiation. For instance, the GHE length was reduced to around half in cooling dominant region using cooling tower, while it was negligible in heating dominant region.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Modeling and optimization of hybrid ground source heat pump with district heating and cooling
    Puttige, Anjan Rao
    Andersson, Staffan
    oestin, Ronny
    Olofsson, Thomas
    ENERGY AND BUILDINGS, 2022, 264
  • [2] Ground source heat pump carbon emissions and ground-source heat pump systems for heating and cooling of buildings: A review
    Ahmadi, Mohammad Hossein
    Ahmadi, Mohammad Ali
    Sadaghiani, Mirhadi S.
    Ghazvini, Mahyar
    Shahriar, Sadegh
    Nazari, Mohammad Alhuyi
    ENVIRONMENTAL PROGRESS & SUSTAINABLE ENERGY, 2018, 37 (04) : 1241 - 1265
  • [3] Heating and cooling performance of a minitype ground source heat pump system
    Zhai, X. Q.
    Cheng, X. W.
    Wang, R. Z.
    APPLIED THERMAL ENGINEERING, 2017, 111 : 1366 - 1370
  • [4] COMPARATIVE STUDY AMONG HYBRID GROUND SOURCE HEAT PUMP SYSTEM, COMPLETE GROUND SOURCE HEAT PUMP AND CONVENTIONAL HVAC SYSTEM
    Zhu, Jiang
    Tao, Yong
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2011, VOL 4, PTS A AND B, 2012, : 693 - 699
  • [5] Experimental Study Of Heating-cooling Combined Ground Source Heat Pump System with Horizontal Ground Heat Exchanger
    Hu, Ying-Ning
    Peng, Ban-Jun
    Hu, Shan-Shan
    Lin, Jun
    SUSTAINABLE DEVELOPMENT OF URBAN ENVIRONMENT AND BUILDING MATERIAL, PTS 1-4, 2012, 374-377 : 398 - 404
  • [6] Cooling dominated Hybrid Ground Source Heat Pump System application
    Sagia, Z.
    Rakopoulos, C.
    Kakaras, E.
    APPLIED ENERGY, 2012, 94 : 41 - 47
  • [7] Ground Source Heat Pump Efficiency in Cold Climates
    Garber-Slaght, Robbin
    Daanen, Ronald
    Roe, Andy
    ASHRAE TRANSACTIONS 2014, VOL 120, PT 2, 2014, 120
  • [8] Ground Source and Sewage Water Source Heat Pump Systems for Block Heating and Cooling Network
    Kim, Min-Hwi
    Kim, Deuk-Won
    Han, Gwangwoo
    Heo, Jaehyeok
    Lee, Dong-Won
    ENERGIES, 2021, 14 (18)
  • [9] Comparative Study of Intermittent Operating Conditions for Hybrid Ground-Source Heat Pump
    Chen, Jin
    Xu, Linghong
    Hu, Pingfang
    Zhu, Na
    2013 INTERNATIONAL CONFERENCE ON MATERIALS FOR RENEWABLE ENERGY AND ENVIRONMENT (ICMREE), VOLS 1-3, 2013, : 942 - 946
  • [10] Environmental impact assessment of ground source heat pump system for heating and cooling: a case study in China
    Yijie Zhai
    Tianzuo Zhang
    Xianfeng Tan
    Guiling Wang
    Longchen Duan
    Qipeng Shi
    Changxing Ji
    Yueyang Bai
    Xiaoxu Shen
    Jia Meng
    Jinglan Hong
    The International Journal of Life Cycle Assessment, 2022, 27 : 395 - 408