VLA detection of the exciting source of the "deflected" HH 270/110 system

被引:0
|
作者
Rodriguez, LF
Reipurth, B
Raga, AC
Canto, J
机构
[1] Univ Nacl Autonoma Mexico, Astron Inst, Mexico City 04510, DF, Mexico
[2] Univ Nacl Autonoma Mexico, Astron Inst, Morelia 58090, Michoacan, Mexico
[3] Univ Colorado, CASA, Boulder, CO 80309 USA
关键词
ISM jets and outflows; radio continuum stars; stars-formation; stars mass-loss;
D O I
暂无
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
The HH object 110 is a well collimated jet that in initial studies seemed to lack an exciting source. More recent studies suggest that the exciting source of this jet is off-axis, producing a faint jet, known as HH 270, which is deflected in a grazing collision with a molecular cloud, thus producing HH 110. We present sensitive observations made at 6 and 3.6-cm with the VLA toward the HH 270/110 system in an attempt to test this hypothesis. An object with characteristics of a thermal radio jet was detected coincident with the infrared object proposed as the exciting source of the HH 270/110 system. This thermal radio jet appears elongated along the direction of HH 270. No radio continuum source was detected at the apex of the HH 110 flow. Altogether, our results thus strongly corroborate the proposed jet-collision interpretation of the BR 110/270 flow complex. Additionally, we have detected at both 3.6 and 6-cm the driving source of the nearby IRAS 05487+0255 bipolar molecular hydrogen jet.
引用
收藏
页码:69 / 72
页数:4
相关论文
共 50 条
  • [31] Development of Odor Compass: Source direction detection system
    Zahid, Mohammed
    Bhute, Tanishqua
    Shirke, Manisha D.
    Gharpure, D. C.
    2015 2ND INTERNATIONAL SYMPOSIUM ON PHYSICS AND TECHNOLOGY OF SENSORS, 2015, : 138 - 141
  • [32] Plume source detection using a process query system
    Nofsinger, GT
    Smith, KW
    CHEMICAL AND BIOLOGICAL SENSING V, 2004, 5416 : 146 - 156
  • [33] Configuration of electro optic fire source detection system
    Fabian, Ram Z.
    Steiner, Zeev
    Hofman, Nir
    SENSORS, AND COMMAND, CONTROL, COMMUNICATIONS AND INTELLIGENCE (C31) TECHNOLOGIES FOR HOMELAND SECURITY AND HOMELAND DEFENSE VI, 2007, 6538
  • [34] DETERMINATION OF OVERALL SYSTEM EFFICIENCY OF AN ENERGY DISPERSIVE-X-RAY FLUORESCENCE SPECTROMETER USING A BREMSSTRAHLUNG EXCITING SOURCE
    COTHERN, CR
    MANUEL, HL
    MILLETTE, RJ
    X-RAY SPECTROMETRY, 1974, 3 (02) : 53 - 58
  • [35] DETECTION OF THE EXCITING SOURCE OF THE SPECTACULAR MOLECULAR OUTFLOW L1448 AT LAMBDA-LAMBDA 1-3 MM
    BACHILLER, R
    ANDRE, P
    CABRIT, S
    ASTRONOMY & ASTROPHYSICS, 1991, 241 (02) : L43 - L46
  • [36] Electromagnetic Detection System with Magnetic Dipole Source for Near-Surface Detection
    Liao, Xian
    Xu, Zhengyu
    Liu, Wei
    Tai, Heng-Ming
    Zhou, Jie
    Ma, Xiao
    Fu, Zhihong
    SENSORS, 2023, 23 (24)
  • [37] Attitude effect on marine magnetic source TEM detection system
    Zhao Y.
    Xu F.
    Cao H.
    Liu J.
    Shiyou Diqiu Wuli Kantan/Oil Geophysical Prospecting, 2022, 57 (05): : 1228 - 1240
  • [38] Multi-source System for Accurate Urban Extension Detection
    Kilani, Hassna
    Ben Abdallah, Hichem
    Abdellatif, Takoua
    Attia, Rabah
    ADVANCES IN REMOTE SENSING AND GEO INFORMATICS APPLICATIONS, 2019, : 69 - 71
  • [39] Air-photonics based terahertz source and detection system
    Emilien Prost
    Vincent Loriot
    Eric Constant
    Isabelle Compagnon
    Luc Bergé
    Franck Lépine
    Stefan Skupin
    The European Physical Journal Special Topics, 2023, 232 : 2157 - 2166
  • [40] Early warning system for detection of microbial contamination of source waters
    Mogensen, Claus Tilsted
    Bentien, Anders
    Lau, Mogens
    Hojris, Bo
    Iversen, Kare
    Klinting, Mette
    Berg, Tommy Winter
    Agersnap, Niels
    Valvik, Martin
    SENSING TECHNOLOGIES FOR GLOBAL HEALTH, MILITARY MEDICINE, DISASTER RESPONSE, AND ENVIRONMENTAL MONITORING AND BIOMETRIC TECHNOLOGY FOR HUMAN IDENTIFICATION VIII, 2011, 8029