Impact strength of cemented implant interfaces

被引:1
|
作者
Kocak, Sait [1 ]
Sekercioglu, Tezcan [2 ]
机构
[1] Pamukkale Univ, Mech Engn Dept, Denizli, Turkey
[2] Pamukkale Univ, Mechatron Engn Dept, Denizli, Turkey
关键词
Bone cement; cemented joint replacement; cement-bone interface; implant-cement interface; impact strength; ACRYLIC BONE-CEMENT; STAINLESS-STEEL INTERFACES; FEMORAL COMPONENTS; MANTLE THICKNESS; IN-VITRO; FAILURE; FRACTURE; SHEAR; MICROMECHANICS; STIFFNESS;
D O I
10.3139/120.111481
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Bone cement is a polymer used as filler material for the attachment of bone to implants in cemented joint replacements. Stronger interdigitation of the bone cement with both the implant and the bone provides a more durable surgical intervention. In previous studies published in the literature to date, tensile, shear and multi-axial stress occurring on the interfaced surfaces of the cement due to static and dynamic loads acting on the femur have been tested. This study investigated the impact strength of both implant-cement and cement-bone interfaces in a cemented implant. The effects of different implant materials, blasting sand particle size and cement mantle thickness on impact strength were investigated. It was determined that the surface roughness values of the implant materials increased as larger blasting sand particles were applied. As the surface roughness increased, the interfacial impact strength also increased. The impact strength of the cement-bone interface was higher than that of the implant-cement interface. The optimum mantle thickness in terms of impact strength was found to be 2 mm. Under impact force, failure will occur at the implant-bone cement interface.
引用
收藏
页码:271 / 276
页数:6
相关论文
共 50 条
  • [1] Impact strength of cemented implant interfaces
    Sekercioglu, Tezcan
    Kocak, Sait
    Materialpruefung/Materials Testing, 2020, 62 (03): : 271 - 276
  • [2] Strength and reinforcement of interfaces in cemented carbides
    Christensen, M
    Wahnström, G
    INTERNATIONAL JOURNAL OF REFRACTORY METALS & HARD MATERIALS, 2006, 24 (1-2): : 80 - 88
  • [3] Effect of alloy type and casting technique on the fracture strength of implant-cemented structures
    Castillo-de Oyaguee, Raquel
    Osorio, Raquel
    Lynch, Christopher
    Gilmour, Alan
    Toledano, Manuel
    MEDICINA ORAL PATOLOGIA ORAL Y CIRUGIA BUCAL, 2011, 16 (04): : E619 - E625
  • [4] Cemented and screwed implant restorations
    Ana, Petre
    Vlad, Naicu
    Ruxandra, Sfeatcu
    2ND FUTURE TREND IN IMPLANTOLOGY INTERNATIONAL DENTAL CONFERENCE (FTI), 2011, : 33 - 39
  • [5] EFFECT OF FIBER ARCHITECTURE ON THE FRACTURE STRENGTH OF IMPLANT/BIO-MATERIAL INTERFACES
    Li, Yanling
    Riahinezhad, Shahram
    Khandaker, M.
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2015, VOL 3, 2016,
  • [6] Impact of Implantoplasty on Strength of the Implant-Abutment Complex
    Chan, Hsun-Liang
    Oh, Won-Suck
    Ong, Hwei Sze
    Fu, Jia-Hui
    Steigmann, Marius
    Sierraalta, Marianella
    Wang, Hom-Lay
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (06) : 1530 - 1535
  • [7] STRENGTH OF CEMENTED GRAINS
    YIN, HZ
    DVORKIN, J
    GEOPHYSICAL RESEARCH LETTERS, 1994, 21 (10) : 903 - 906
  • [8] Cemented implant-supported restorations
    Wolfart, Stefan
    Kern, Matthias
    IMPLANTOLOGIE, 2015, 23 (02): : 161 - 172
  • [9] Is There a Correlation Between Tensile Strength and Retrievability of Cemented Implant-Retained Crowns Using Artificial Aging?
    Mehl, Christian
    Ali, Shurouk
    El Bahra, Shadi
    Harder, Soenke
    Vollrath, Oliver
    Kern, Matthias
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2016, 29 (01) : 83 - 90
  • [10] Assessing Fluoride Impact in Phosphogypsum: Strength and Leaching Behavior of Cemented Paste Backfill
    Zhang, Qinli
    Yang, Yikun
    Wang, Daolin
    Liu, Bin
    Feng, Yan
    Song, Zian
    Chen, Qiusong
    APPLIED SCIENCES-BASEL, 2024, 14 (23):