The pressure drop across the endotracheal tube in mechanically ventilated pediatric patients

被引:14
|
作者
Spaeth, Johannes [1 ]
Steinmann, Daniel [2 ]
Kaltofen, Heike [1 ]
Guttmann, Josef [1 ]
Schumann, Stefan [1 ]
机构
[1] Univ Med Ctr Freiburg, Dept Anesthesiol & Intens Care Med, D-79106 Freiburg, Germany
[2] Univ Med Ctr Freiburg, Dept Occupat Hlth, D-79106 Freiburg, Germany
关键词
equipment - tubes tracheal; anesthesia; -; pediatric; ventilation; mechanical; ventilation - airway pressure; airway; resistance; respiratory; mechanics; SPONTANEOUSLY BREATHING PATIENTS; INTRATRACHEAL PRESSURE; TRACHEAL PRESSURE; ADDITIONAL WORK; RESISTANCE; COMPENSATION; OBSTRUCTION; CONNECTORS; CHILDREN; SUPPORT;
D O I
10.1111/pan.12595
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
BackgroundDuring mechanical ventilation, the airway pressure (P-aw) is usually monitored. However, P-aw comprises the endotracheal tube (ETT)-related pressure drop (P-ETT) and thus does not reflect the pressure in the patients' lungs. Therefore, monitoring of mechanical ventilation should be based on the tracheal pressure (P-trach). We systematically investigated potential factors influencing P-ETT in pediatric ETTs. MethodsIn this study, the flow-dependent pressure drop across pediatric ETTs from four manufacturers [2.0-4.5mm inner diameter (ID)] was estimated in a physical model of the upper airways. Additionally, P-ETT was examined with the ETTs shortened to 75% of their original length and at different curvatures. In nine healthy mechanically ventilated children (aged between 9days and 29months), P-trach was compared to P-aw. ResultsP(ETT) was nonlinearly flow dependent. Low IDs corresponded to high P-ETT. Differences between ETTs from different manufacturers were identified. Shortening of the ETTs' length by 25% reduced P-ETT on average by 14% of the value at original length. Ventilation frequency and tube curvature did not influence P-ETT to a relevant extent. In the pediatric patients, the root mean square deviation between P-aw and P-trach was 2.3cm H2O. ConclusionP(aw) and P-trach differ considerably (by P-ETT) during mechanical ventilation of pediatric patients. The ETTs' ID, tube length, and manufacturer type are significant factors for P-ETT and should be taken into account when P-aw is valuated. For this purpose, P-trach can be continuously calculated with good precision by means of the Rohrer approximation.
引用
收藏
页码:413 / 420
页数:8
相关论文
共 50 条
  • [31] Reproducibility of quantitative cultures of endotracheal aspirates from mechanically ventilated patients
    Bergmans, DCJJ
    Bonten, MJM
    DeLeeuw, PW
    Stobberingh, EE
    JOURNAL OF CLINICAL MICROBIOLOGY, 1997, 35 (03) : 796 - 798
  • [32] Utility of Endotracheal Tube Cuff Pressure Monitoring in Mechanically Ventilated (MV) Children in Preventing Post-extubation Stridor (PES)
    Shaikh, Farhan
    Janaapureddy, Yeshwanth R.
    Mohanty, Shashwat
    Reddy, Preetham K.
    Sachane, Kapil
    Dekate, Parag S.
    Yerra, Anupama
    Chirla, Dinesh
    INDIAN JOURNAL OF CRITICAL CARE MEDICINE, 2021, 25 (02) : 181 - 184
  • [33] Evaluation of optimal positive end-expiratory pressure in mechanically ventilated pediatric patients
    Hipp, BL
    Gaskin, P
    Gentile, MA
    Cheifetz, IM
    Meliones, J
    CRITICAL CARE MEDICINE, 1999, 27 (12) : A113 - A113
  • [34] Airway opening pressure maneuver to detect airway closure in mechanically ventilated pediatric patients
    Guerineau, Luciana Rodriguez
    Vieira, Fernando
    Rodrigues, Antenor
    Reise, Katherine
    Todd, Mark
    Guerguerian, Anne-Marie
    Brochard, Laurent
    FRONTIERS IN PEDIATRICS, 2024, 12
  • [35] An endotracheal tube providing “pressurized sealing” prevents fluid leakage in mechanically ventilated critically ill patients: a pilot study
    Herbert Spapen
    Emiel Suys
    Jouke De Regt
    Joris Troubleyn
    Joop Jonckheer
    Elisabeth De Waele
    Journal of Anesthesia, 2020, 34 : 144 - 148
  • [36] An endotracheal tube providing "pressurized sealing" prevents fluid leakage in mechanically ventilated critically ill patients: a pilot study
    Spapen, Herbert
    Suys, Emiel
    De Regt, Jouke
    Troubleyn, Joris
    Jonckheer, Joop
    De Waele, Elisabeth
    JOURNAL OF ANESTHESIA, 2020, 34 (01) : 144 - 148
  • [37] Microbial diversity and antimicrobial susceptibility in endotracheal tube biofilms recovered from mechanically ventilated COVID-19 patients
    van Charante, Frits
    Wieme, Anneleen
    Rigole, Petra
    De Canck, Evelien
    Ostyn, Lisa
    Grassi, Lucia
    Deforce, Dieter
    Crabbe, Aurelie
    Vandamme, Peter
    Joossens, Marie
    Van Nieuwerburgh, Filip
    Depuydt, Pieter
    Coenye, Tom
    BIOFILM, 2022, 4
  • [38] Closed versus open endotracheal tube suction in mechanically ventilated neonates: a randomized controlled trial
    Gahan, Ajaya Kumar
    Jain, Suksham
    Khurana, Supreet
    Chawla, Deepak
    EUROPEAN JOURNAL OF PEDIATRICS, 2023, 182 (02) : 785 - 793
  • [39] MEASUREMENT OF DISTAL AIRWAY PRESSURES IN MECHANICALLY VENTILATED INFANTS WITH A NEW DESIGNED ENDOTRACHEAL-TUBE
    TRANG, TTH
    AZEMA, D
    BOUSSIGNAC, G
    MERCIER, JC
    LESCOEURBERG, B
    BEAUFILS, F
    INTENSIVE CARE MEDICINE, 1987, 13 (06) : 446 - 446
  • [40] PNEUMOTHORAX DUE TO BALL-VALVE OBSTRUCTION OF AN ENDOTRACHEAL-TUBE IN A MECHANICALLY VENTILATED PATIENT
    RUSSOMANNO, JH
    BROWN, LK
    CHEST, 1992, 101 (05) : 1444 - 1445