Transient measurement with an enzyme-immobilized electrode undergoing protein adsorption

被引:3
|
作者
Aoyagi, S
Suzuki, Y
Sakai, K
Miyasaka, T
Yoshimi, Y
机构
[1] Waseda Univ, Dept Chem Engn, Shinjuku Ku, Tokyo 1698555, Japan
[2] Kawasaki Med Sch, Dept Physiol, Kurashiki, Okayama 7010192, Japan
[3] Shibaura Inst Technol, Dept Ind Chem, Minato Ku, Tokyo 1088548, Japan
关键词
transient state; glucose; glucose oxidase; on-off control;
D O I
10.5796/electrochemistry.69.251
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A measurement without the influence of protein adsorption on the sensor surface has been developed using transient current of an enzyme-immobilized electrode. Response current decreases due to protein adsorption on the sensor surface and the enzyme-immobilized membrane causing glucose concentration gradient. By measuring glucose concentration in the transient state while controlling GOD activity, it is possible to prevent the influence of protein adsorption. A needle-type electrode glucose sensor on which enzyme is immobilized with a polyurethane membrane, with electrochemical on-off control of enzyme activity, is capable of accurate measurement of glucose concentration in bovine serum at least for 24 hrs.
引用
收藏
页码:251 / 253
页数:3
相关论文
共 50 条
  • [1] Application of Polyammonium Cations to Enzyme-immobilized Electrode: Application as Enzyme Stabilizer for Bilirubin Oxidase
    Katano, Hajime
    Tatsumi, Hirosuke
    Hibi, Takao
    Ikeda, Tokuji
    Tsukatani, Toshihide
    ANALYTICAL SCIENCES, 2008, 24 (11) : 1421 - 1424
  • [2] Application of Polyammonium Cations to Enzyme-immobilized Electrode: Application as Enzyme Stabilizer for Bilirubin Oxidase
    Hajime Katano
    Hirosuke Tatsumi
    Takao Hibi
    Tokuji Ikeda
    Toshihide Tsukatani
    Analytical Sciences, 2008, 24 : 1421 - 1424
  • [3] Disposable amperometric glucose sensor electrode with enzyme-immobilized nitrocellulose strip
    Cui, G
    Yoo, JH
    Woo, BW
    Kim, SS
    Cha, GS
    Nam, H
    TALANTA, 2001, 54 (06) : 1105 - 1111
  • [4] Enzyme-Immobilized Microfluidic Process Reactors
    Asanomi, Yuya
    Yamaguchi, Hiroshi
    Miyazaki, Masaya
    Maeda, Hideaki
    MOLECULES, 2011, 16 (07) : 6041 - 6059
  • [5] Miniaturization of multifunctional biosensor with enzyme-immobilized beads
    Murakami, Y
    Yokoyama, K
    Tamiya, E
    MICRO- AND NANOFABRICATED STRUCTURES AND DEVICES FOR BIOMEDICAL ENVIRONMENTAL APPLICATIONS, 1998, 3258 : 11 - 14
  • [6] Behavior of a Microelectrode with a Concentrated Enzyme-Immobilized Layer
    Hashimoto, Masatoshi
    Sakamoto, Naohisa
    Upadhyay, Sanjay
    Suzuki, Hiroaki
    2006 IEEE SENSORS, VOLS 1-3, 2006, : 358 - +
  • [7] Enzyme-immobilized microfluidic devices for biomolecule detection
    Yamaguchi, Hiroshi
    Miyazaki, Masaya
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2023, 159
  • [8] ENZYME-IMMOBILIZED SH-SAW BIOSENSOR
    KONDOH, J
    MATSUI, Y
    SHIOKAWA, S
    WLODARSKI, WB
    SENSORS AND ACTUATORS B-CHEMICAL, 1994, 20 (2-3) : 199 - 203
  • [9] Enzyme-Immobilized Porous Crystals for Environmental Applications
    Wang, Hao
    Kou, Xiaoxue
    Gao, Rui
    Huang, Siming
    Chen, Guosheng
    Ouyang, Gangfeng
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2024, 58 (27) : 11869 - 11886
  • [10] ENZYME-IMMOBILIZED LANGMUIR-BLODGETT FILM FOR A BIOSENSOR
    SRIYUDTHSAK, M
    YAMAGISHI, H
    MORIIZUMI, T
    THIN SOLID FILMS, 1988, 160 (1-2) : 463 - 469