The effects of gray scale image processing on digital mammography interpretation performance

被引:22
|
作者
Cole, EB
Pisano, ED
Zeng, DL
Muller, K
Aylward, SR
Park, S
Kuzmiak, C
Koomen, M
Pavic, D
Walsh, R
Baker, J
Gimenez, EI
Freimanis, R
机构
[1] Univ N Carolina, Dept Radiol, Radiat Res Lab, Chapel Hill, NC 27599 USA
[2] Univ N Carolina, Lineberger Comprehens Canc Ctr, Chapel Hill, NC 27599 USA
[3] Univ N Carolina, Dept Biostat, Chapel Hill, NC 27599 USA
[4] Duke Univ, Med Ctr, Dept Radiol, Durham, NC 27710 USA
[5] Wake Forest Univ, Dept Radiol, Winston Salem, NC USA
关键词
digital mammography; ROC curve; image processing;
D O I
10.1016/j.acra.2005.01.017
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. To determine the effects of three image-processing algorithms on diagnostic accuracy of digital mammography in comparison with conventional screen-film mammography. Materials and Methods. A total of 201 cases consisting of nonprocessed soft copy versions of the digital mammograms acquired from GE, Fischer, and Trex digital mammography systems (1997-1999) and conventional screen-film mammograms of the same patients were interpreted by nine radiologists. The raw digital data were processed with each of three different image-processing algorithms creating three presentations - manufacturer's default (applied and laser printed to film by each of the manufacturers), MUSICA, and PLAHE - were presented in soft copy display. There were three radiologists per presentation. Results. Area under the receiver operating characteristic curve for GE digital mass cases was worse than screen-film for all digital presentations. The area under the receiver operating characteristic for Trex digital mass cases was better, but only with images processed with the manufacturer's default algorithm. Sensitivity for GE digital mass cases was worse than screen film for all digital presentations. Specificity for Fischer digital calcifications cases was worse than screen film for images processed in default and PLAHE algorithms. Specificity for Trex digital calcifications cases was worse than screen film for images processed with MUSICA. Conclusion. Specific image-processing algorithms may be necessary for optimal presentation for interpretation based on machine and lesion type. © AUR, 2005.
引用
收藏
页码:585 / 595
页数:11
相关论文
共 50 条
  • [21] Towards a modality-independent image processing workstation for digital mammography
    Seibert, J.
    Kennedy, B.
    Cavanaugh, B.
    Barnett, C.
    MEDICAL PHYSICS, 2007, 34 (06) : 2360 - 2360
  • [22] Digital and screen-film mammography: Comparison of image acquisition and interpretation times
    Berns, EA
    Hendrick, RE
    Solari, M
    Barke, L
    Reddy, D
    Wolfman, J
    Segal, L
    DeLeon, P
    Benjamin, S
    Willis, L
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 187 (01) : 38 - 41
  • [23] Image standardization for digital mammography
    Velthuizen, RP
    Clarke, LP
    DIGITAL MAMMOGRAPHY, 1998, 13 : 461 - 464
  • [24] Effects of pixel/aperture sizes on image properties in digital mammography
    Liu, XM
    Shaw, CC
    Rong, JX
    Whitman, GJ
    MEDICAL IMAGING 2000: PHYSICS OF MEDICAL IMAGING, 2000, 3977 : 159 - 166
  • [25] Radiation Effects Quantification in Breast Radiotherapy by Mammography Image Processing
    Sotiropoulos, M.
    Zygogianni, A.
    Lagopati, N.
    Antypas, C.
    Arbillia, C.
    Kouvaris, J.
    Lyra, M. E.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 5, 2009, 25 : 362 - +
  • [26] Effects of Lesion Positioning on Digital Magnification Mammography Performance
    Liu, Franklin
    Kanal, Kalpana M.
    Stewart, Brent K.
    Lehman, Constance D.
    ACADEMIC RADIOLOGY, 2010, 17 (06) : 791 - 794
  • [27] Digital image processing for the interpretation of radiographs used for condition monitoring
    Thale, W
    Clausen, R
    Just, T
    INSIGHT, 1996, 38 (09) : 632 - 635
  • [28] Application of digital image processing to radiographs for the interpretation of corrosion cracks
    Just, T
    Clausen, R
    Thale, W
    MATERIALS AND CORROSION-WERKSTOFFE UND KORROSION, 1998, 49 (11): : 805 - 808
  • [29] Neighborhood operation gray-scale image algebra for optical morphological image processing
    Cheng, Gang
    Jin, Guofan
    Wu, Minxian
    He, Qingsheng
    Liu, Haisong
    Yan, Yingbai
    Guangdianzi Jiguang/Journal of Optoelectronics Laser, 1998, 9 : 202 - 204
  • [30] Diagnostic accuracy of digital mammography in patients with dense breasts who underwent problem-solving mammography: Effects of image processing and lesion type
    Cole, EB
    Pisano, ED
    Kistner, EO
    Muller, KE
    Brown, ME
    Feig, SA
    Jong, RA
    Maidment, ADA
    Staiger, MJ
    Kuzmiak, CM
    Freimanis, RI
    Lesko, N
    Rosen, EL
    Walsh, R
    Williford, M
    Braeuning, MP
    RADIOLOGY, 2003, 226 (01) : 153 - 160