Assessment of carbon monoxide concentration in indoor/outdoor air of Sarayan city, Khorasan Province of Iran

被引:17
|
作者
Naghizadeh, Ali [1 ]
Sharifzadeh, Gholamreza [2 ]
Tabatabaei, Fatemeh [3 ]
Afzali, Afsaneh [3 ]
Yari, Ahmad Reza [4 ]
Geravandi, Sahar [5 ]
Mohammadi, Mohammad Javad [6 ,7 ]
机构
[1] BUMS, Med Toxicol & Drug Abuse Res Ctr MTDRC, Birjand, Iran
[2] BUMS, Social Determinants Hlth Res Ctr, Birjand, Iran
[3] BUMS, Fac Hlth, Dept Environm Hlth Engn, Birjand, Iran
[4] Qom Univ Med Sci, Res Ctr Environm Pollutants, Qom, Iran
[5] Asadabad Sch Med Sci, Asadabad, Iran
[6] Ahvaz Jundishapur Univ Med Sci, Sch Publ Hlth, Dept Environm Hlth Engn, Ahvaz, Iran
[7] Ahvaz Jundishapur Univ Med Sci, Environm Technol Res Ctr, Ahvaz, Iran
关键词
Carbon monoxide; Air pollution; Indoor; Outdoor; Environment; Iran; ASSOCIATION; POLLUTANTS; IMPACT; AHVAZ;
D O I
10.1007/s10653-018-0226-5
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Nowadays, air pollution by humans is considered a serious problem. One of the main sources of air pollution is carbon monoxide which is called the silent killer. With the increasing rate of population growth in Iran and subsequent acceleration of vehicle and fossil fuel usage, the mortality rate of carbon monoxide has increased. The aim of this study is assessment of the concentration of carbon monoxide in indoor and outdoor air of Sarayan city, Khorasan Province of Iran. In this descriptive-analytic study, the air condition of a residential area and outdoor environment of Sarayan city has been monitored for determining the carbon monoxide concentration during a 3-month period from January to March 2017. Overall, 25 stations with uniform distribution were located in the city. Fifty samples were taken monthly and by considering 3-month period, a total of 150 samples were gathered. The samples were taken in kitchens between 11 a.m. and 3 p.m., and by considering the respiratory height of the human body, the carbon monoxide meters (TES model, Taiwan) were placed at a height of 75-150 cm. The descriptive statistics were presented after entering data into SPSS-16, and, by applying Mann-Whitney and Kruskal-Wallis tests in the case of alpha=0.05, the data were analyzed. The average concentrations of carbon monoxide in indoor and outdoor environments were 0.84 +/- 3.21 ppm and 0.27 +/- 0.92 ppm, respectively. The maximum carbon monoxide concentration in February in an outdoor environment was 6 ppm (station no. 4) and the least one was 0 ppm. In March, for an indoor area, the maximum carbon monoxide concentration was 41 pm for station no. 11. The indoor-to-outdoor (I-to-O) ratio in March was higher than other months, and in January, was less than others. The study reveals that the indoor and outdoor carbon monoxide indices of Sarayan city are at acceptable levels.
引用
收藏
页码:1875 / 1880
页数:6
相关论文
共 50 条
  • [41] Dynamics of carbon dioxide concentration in indoor air
    Andrzej Szczurek
    Monika Maciejewska
    Rafał Połoczański
    Marek Teuerle
    Agnieszka Wyłomańska
    Stochastic Environmental Research and Risk Assessment, 2015, 29 : 2193 - 2199
  • [42] Carbonyl levels in indoor and outdoor air in Mexico City and Xalapa, Mexico
    Báez, A
    Padilla, H
    García, R
    Torres, MD
    Rosas, I
    Belmont, R
    SCIENCE OF THE TOTAL ENVIRONMENT, 2003, 302 (1-3) : 211 - 226
  • [43] Study of indoor and outdoor air pollutants beside the trunk road in city
    Zhang, DF
    Huang, XJ
    Yang, XY
    Ma, XD
    Liu, JB
    Weng, J
    BUILT ENVIRONMENT AND PUBLIC HEALTH, PROCEEDINGS, 2004, : 68 - 74
  • [44] ASSESSMENT OF AIR QUALITY WITH INDOOR AND OUTDOOR CONDITIONS IN WUHAN, CHINA
    Ye, Xiaojiang
    Chen, Huanxin
    Zhou, Zhaoxia
    Li, Duanyong
    Hou, Zhijian
    Lu, Liangyan
    Zhou, Wei
    Qing, E.
    FIFTH INTERNATIONAL WORKSHOP ON ENERGY AND ENVIRONMENT OF RESIDENTIAL BUILDINGS AND THIRD INTERNATIONAL CONFERENCE ON BUILT ENVIRONMENT AND PUBLIC HEALTH, VOL I AND II, PROCEEDINGS, 2009, : 937 - 943
  • [45] STUDY ON HUMAN EXPOSURE ASSESSMENT TO INDOOR/OUTDOOR AIR POLLUTANTS
    曹梦霞
    林盛
    刘金兰
    张林
    孙咏梅
    Transactions of Tianjin University, 1997, (02)
  • [46] Assessment of 7Be concentration in outdoor ambient air
    Khan, S.
    Alaamer, A. S.
    Tahir, S. N. A.
    HEALTH PHYSICS, 2008, 95 (04): : 433 - 435
  • [47] Investigation of health risk assessment sevoflurane on indoor air quality in the operation room in Ahvaz city, Iran
    Neisi, Abdolkazem
    Albooghobeish, Masoumeh
    Geravandi, Sahar
    Behrooz, Hamid Reza Adeli
    Mahboubi, Mohammad
    Khaniabad, Yusef Omidi
    Valipour, Aliasghar
    Karimyan, Azimeh
    Mohammadi, Mohammad Javad
    Farhadi, Majid
    Yari, Ahmad Reza
    Ghomeishi, Ali
    TOXIN REVIEWS, 2019, 38 (02) : 151 - 159
  • [48] The concentration data of fluoride and health risk assessment in drinking water in the Ardakan city of Yazd province, Iran
    Mirzabeygi , Majid
    Yousefi, Mahmood
    Soleimani, Hamed
    Mohammadi, Ali Akbar
    Mahvi, Amir Hossein
    Abbasnia, Abbas
    DATA IN BRIEF, 2018, 18 : 40 - 46
  • [49] Dataset of fluoride concentration and health risk assessment in drinking water in the Saveh City of Markazi Province, Iran
    Tashauoei, Hamid Reza
    Mahdavi, Mokhtar
    Mahvi, Amir Hossein
    Fatehizadeh, Ali
    DATA IN BRIEF, 2023, 50
  • [50] Air quality in relation to carbon monoxide concentration levels
    Canales-Manchuria, Fabrizzio
    Canales-Manchuria, Gelvi
    Canales-Gutierrez, Angel
    ATELIE GEOGRAFICO, 2023, 17 (01): : 50 - 68