Refractory ineffective triggering during pressure support ventilation: effect of proportional assist ventilation with load-adjustable gain factors

被引:1
|
作者
Haudebourg, Anne-Fleur [1 ,2 ]
Maraffi, Tommaso [2 ,4 ]
Tuffet, Samuel [1 ,2 ,3 ]
Perier, Francois [1 ,2 ]
de Prost, Nicolas [1 ,2 ]
Razazi, Keyvan [1 ,2 ]
Mekontso Dessap, Armand [1 ,2 ]
Carteaux, Guillaume [1 ,2 ,3 ]
机构
[1] Hop Univ Henri Mondor Albert Chenevier, AP HP, Serv Med Intens Reanimat, DHU A TVB, Creteil, France
[2] Univ Paris Est Creteil, Fac Med Creteil, Grp Rech Clin CARMAS, IMRB, Creteil, France
[3] Inst Mondor Rech Biomed, INSERM 955, Creteil, France
[4] Ctr Hosp Intercommunal Creteil, Serv Reanimat & Surveillance Continue Adulte, F-94000 Creteil, France
关键词
Mechanical ventilation; Patient; Ventilator asynchrony; Ineffective triggering; Proportional assist ventilation; END-EXPIRATORY PRESSURE; MECHANICAL VENTILATION; INSPIRATORY EFFORT; DEPENDENT PATIENTS; ASYNCHRONY; ESOPHAGEAL; DURATION;
D O I
10.1186/s13613-021-00935-0
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background Ineffective triggering is frequent during pressure support ventilation (PSV) and may persist despite ventilator adjustment, leading to refractory asynchrony. We aimed to assess the effect of proportional assist ventilation with load-adjustable gain factors (PAV+) on the occurrence of refractory ineffective triggering. Design Observational assessment followed by prospective cross-over physiological study. Setting Academic medical ICU. Patients Ineffective triggering was detected during PSV by a twice-daily inspection of the ventilator's screen. The impact of pressure support level (PSL) adjustments on the occurrence of asynchrony was recorded. Patients experiencing refractory ineffective triggering, defined as persisting asynchrony at the lowest tolerated PSL, were included in the physiological study. Interventions Physiological study: Flow, airway, and esophageal pressures were continuously recorded during 10 min under PSV with the lowest tolerated PSL, and then under PAV+ with the gain adjusted to target a muscle pressure between 5 and 10 cmH(2)O. Measurements Primary endpoint was the comparison of asynchrony index between PSV and PAV+ after PSL and gain adjustments. Results Among 36 patients identified having ineffective triggering under PSV, 21 (58%) exhibited refractory ineffective triggering. The lowest tolerated PSL was higher in patients with refractory asynchrony as compared to patients with non-refractory ineffective triggering. Twelve out of the 21 patients with refractory ineffective triggering were included in the physiological study. The median lowest tolerated PSL was 17 cmH(2)O [12-18] with a PEEP of 7 cmH(2)O [5-8] and FiO(2) of 40% [39-42]. The median gain during PAV+ was 73% [65-80]. The asynchrony index was significantly lower during PAV+ than PSV (2.7% [1.0-5.4] vs. 22.7% [10.3-40.1], p < 0.001) and consistently decreased in every patient with PAV+. Esophageal pressure-time product (PTPes) did not significantly differ between the two modes (107 cmH(2)O/s/min [79-131] under PSV vs. 149 cmH(2)O/s/min [129-170] under PAV+, p = 0.092), but the proportion of PTPes lost in ineffective triggering was significantly lower with PAV+ (2 cmH(2)O/s/min [1-6] vs. 8 cmH(2)O/s/min [3-30], p = 0.012). Conclusions Among patients with ineffective triggering under PSV, PSL adjustment failed to eliminate asynchrony in 58% of them (21 of 36 patients). In these patients with refractory ineffective triggering, switching from PSV to PAV+ significantly reduced or even suppressed the incidence of asynchrony.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Pressure vs flow triggering during pressure support ventilation
    Goulet, R
    Hess, D
    Kacmarek, RM
    CHEST, 1997, 111 (06) : 1649 - 1653
  • [32] Proportional assist ventilation versus pressure support ventilation for weaning from mechanical ventilation in adults: weaning success and mortality
    Ioannis Pantazopoulos
    Georgios Mavrovounis
    Maria Mermiri
    Christos Kampolis
    Critical Care, 25
  • [33] Proportional assist ventilation versus pressure support ventilation for weaning from mechanical ventilation in adults: weaning success and mortality
    Pantazopoulos, Ioannis
    Mavrovounis, Georgios
    Mermiri, Maria
    Kampolis, Christos
    CRITICAL CARE, 2021, 25 (01)
  • [34] Data on respiratory variables in critically ill patients with acute respiratory failure placed on proportional assist ventilation with load adjustable gain factors (PAV+)
    Georgopoulos, Dimitris
    Xirouchaki, Nectaria
    Tzanakis, Nikolaos
    Younes, Magdy
    DATA IN BRIEF, 2016, 8 : 484 - 493
  • [35] Noninvasive proportional assist ventilation compared with noninvasive pressure support ventilation in hypercapnic acute respiratory failure
    Wysocki, M
    Richard, JC
    Meshaka, P
    CRITICAL CARE MEDICINE, 2002, 30 (02) : 323 - 329
  • [36] Noninvasive pressure support versus proportional assist ventilation in acute respiratory failure
    Miguel Fernández-Vivas
    Juan Caturla-Such
    Javier González de la Rosa
    José Acosta-Escribano
    Bernabé Álvarez-Sánchez
    José Cánovas-Robles
    Intensive Care Medicine, 2003, 29 : 1126 - 1133
  • [37] Noninvasive pressure support versus proportional assist ventilation in acute respiratory failure
    Fernández-Vivas, M
    Caturla-Such, J
    de la Rosa, JG
    Acosta-Escribano, J
    Alvarez-Sánchez, B
    Cánovas-Robles, J
    INTENSIVE CARE MEDICINE, 2003, 29 (07) : 1126 - 1133
  • [38] Patient–ventilator synchrony and sleep quality with proportional assist and pressure support ventilation
    C. Alexopoulou
    E. Kondili
    M. Plataki
    D. Georgopoulos
    Intensive Care Medicine, 2013, 39 : 1040 - 1047
  • [39] A Pilot Randomized Trial Comparing Weaning From Mechanical Ventilation on Pressure Support Versus Proportional Assist Ventilation
    Bosma, Karen J.
    Read, Brooke A.
    Nikoo, Mohammad J. Bahrgard
    Jones, Philip M.
    Priestap, Fran A.
    Lewis, James F.
    CRITICAL CARE MEDICINE, 2016, 44 (06) : 1098 - 1108
  • [40] Respiratory comfort and breathing pattern during volume proportional assist ventilation and pressure support ventilation:: A study on volunteers with artificially reduced compliance
    Mols, G
    von Ungern-Sternberg, B
    Rohr, E
    Haberthür, C
    Geiger, K
    Guttmann, J
    CRITICAL CARE MEDICINE, 2000, 28 (06) : 1940 - 1946