Correlation between blood flow patterns and intimal hyperplasia at the distal end-to-side anastomosis

被引:0
|
作者
Xu, ZP [1 ]
Deng, XY [1 ]
Fan, YB [1 ]
Liu, LJ [1 ]
Bi, YP [1 ]
Yang, QH [1 ]
机构
[1] Chongqing Univ, Chongqing 630044, Peoples R China
关键词
artery bypass; intimal hyperplasia; blood flow patterns;
D O I
暂无
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
OBJECTIVE: To clarify the relationship between intimal hyperplasia and blood flow patterns in the host artery floor of the distal end-to-side anastomosis. MATERIALS AND METHODS: 32 dogs were used to construct 30 degrees, 45 degrees, 60 degrees and S-type anastomoses at the common carotid artery site with autogenous graft from the canine external jugular vein. Two months after operation, the bypassed arteries were harvested and histologic sections of the distal anastomoses were performed to determine the thickness of neointima. Flow patterns at the distal end-to-side anastomosis were analysed using particle image velocimetry (PIV) by rendering the bypassed arteries transparent. RESULTS: The averaged thicknesses of neointima in 30 degrees, 45 degrees, 60 degrees and S-type anastomoses were 45.26 +/- 5.99, 65.56 +/- 6.53, 119.50 +/- 10.30, 47.64 +/- 4.85 pin respectively vs 9.81 +/- 1.88 mu m in the control group. The flow patterns for different anastomotic angles were characterized by slow recirculation zones distal to the end-to-side anastomosis. The fluid velocity in the recirculation zone was the highest for the 30 degrees anastomosis and the slowest for 60 degrees anastomosis. CONCLUSION: Vascular intimal hyperplasia had a close relationship with blood flow patterns after bypass surgery. The larger the anastomotic angle, the thicker the intimal hyperplasia at the host artery floor of the distal end-to-side anastomosis.
引用
收藏
页码:77 / 80
页数:4
相关论文
共 50 条
  • [31] Flow waveform effects on end-to-side anastomotic flow patterns
    Ethier, CR
    Steinman, DA
    Zhang, X
    Karpik, SR
    Ojha, M
    JOURNAL OF BIOMECHANICS, 1998, 31 (07) : 609 - 617
  • [32] A TECHNIQUE FOR END-TO-SIDE VASCULAR ANASTOMOSIS
    RAO, VP
    THOMAS, CY
    ARCHIVES OF SURGERY, 1970, 101 (01) : 91 - &
  • [33] End-to-side anastomosis to the external jugular vein: preservation of external jugular vein blood flow
    Nagata, Tetsuji
    Masumoto, Kazuma
    Watanabe, Yoshiko
    Katou, Fuminori
    BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2012, 50 (02): : E31 - E32
  • [34] Experimental research on end-to-side anastomosis of peripheral nerves and effect of FK506 on end-to-side anastomosis
    Yang, L. M.
    Wu, Y. X.
    Zhang, X. P.
    Li, X. H.
    BRATISLAVA MEDICAL JOURNAL-BRATISLAVSKE LEKARSKE LISTY, 2014, 115 (10): : 625 - 631
  • [35] INFLUENCE OF TYPE OF ANASTOMOSIS - END-TO-SIDE ANASTOMOSIS VERSUS END-TO-END
    TIBBS, DJ
    JOURNAL OF CARDIOVASCULAR SURGERY, 1975, 16 (04): : 401 - 403
  • [36] Numerical simulation of pulsating flow in a coronary end-to-side anastomosis model
    Huang, Hsing-Ming
    Tang, Tongdar
    Shih, Chun-Che
    Transactions of the Aeronautical and Astronautical Society of the Republic of China, 1999, 31 (04): : 293 - 299
  • [37] Unsteady simulation of distal blood flow in an end-to-side anastomosed coronary bypass graft with stenosis
    Najarian, Siamak
    Dargahi, Javad
    Firouzi, Faramarz
    Afsari, Jamshid
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2006, 16 (05) : 337 - 347
  • [38] MODELING PULSATILE BLOOD FLOW IN END-TO-SIDE ANASTOMOSES
    Cook, Daniel P.
    Thompson, Christopher M.
    JIM EVANS: HONORARY SYMPOSIUM, 2010, 2010, : 385 - 392
  • [39] THE EFFECT OF AN INTRALUMINAL STENT ON NEOINTIMAL HYPERPLASIA AT AN END-TO-SIDE POLYTETRAFLUOROETHYLENE GRAFT ARTERIAL ANASTOMOSIS
    CHALMERS, RTA
    HOBALLAH, JJ
    SHARP, WJ
    KRESOWIK, TF
    CORSON, JD
    AMERICAN JOURNAL OF SURGERY, 1994, 168 (02): : 85 - 90
  • [40] A numerical study of blood flow patterns in anatomically realistic and simplified end-to-side anastomoses
    Moore, JA
    Steinman, DA
    Prakash, S
    Johnston, KW
    Ethier, CR
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1999, 121 (03): : 265 - 272