Analytical performance validation and clinical application of blood gas analyzer on the detection of neonatal bilirubin

被引:3
|
作者
Kuang, Zhaozhong [1 ]
Zong, Xiaolong [2 ]
Xing, Shuang [3 ]
Zhao, Fuguang [3 ]
Guo, Shanshan [3 ]
Li, Huiqiang [1 ]
Wei, Dianjun [4 ]
机构
[1] Tianjin Med Univ, Sch Med Lab Sci, Tianjin, Peoples R China
[2] Tianjin Med Univ, Hosp 2, Dept Lab, Tianjin, Peoples R China
[3] Tanggu Obstet & Gynecol Hosp, Dept Lab, Binhai New Area, Tianjin, Peoples R China
[4] Yanda Hosp, Dept Lab, Langfang, Hebei, Peoples R China
关键词
Newborn; bilirubin; blood gas analyzer; biochemical analyzer; consistency; HYPERBILIRUBINEMIA;
D O I
10.21037/tp-21-541
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Background: It is not yet clear whether the trace blood gas analyzer can be used for biochemical detection of newborns. This study aimed to evaluate the reliability of the method for the detection of bilirubin in infants. Method: Based on the CLSI EP15-A2 document, the analytical performance of the blood gas analyzer method for bilirubin detection in neonates was validated. The resulting data of 363 simultaneous bilirubin detection with blood gas analyzer (optical method) and biochemical analyzer (enzymatic method) were reviewed. According to the CLSI EP9-A3 document, the relevance and consistency of the measurement results were evaluated by Pearson correlation analysis, Passing-Bablok regression, and Bland-Altman deviation analysis. Results: The precision and accuracy of the Werfen GEM 4000 blood gas analyzer for the detection of different levels of bilirubin samples adhered to the manufacturer's statement and industry quality standards. The bilirubin detection values of the 2 methods showed a good correlation, and both of them were significantly correlated (P<0.001). Passing-Bablok regression results showed that the regression equation of the bilirubin detection value of the 2 methods is y = -21.00 + 1.17x, with the slope as 1.17 [95% confidence interval (CI): 1.15 to 1.19], and the intercept was -21.00 (95% CI: -23.62 to -18.71), the data of the 2 sets were not consistent in each concentration range. The Bland-Altman plot demonstrated that the bilirubin detection value of 16/363 cases (4.4%) for the 2 methods exceeded the 95% limits of agreement (95% LoA); of which the maximum bias was -30.34 (95% CI: -38.48 to -22.26) and there were 5/76 cases (6.6%) outside the 95% LoA in the >300 mu mol/L group. Conclusions: The method for detecting neonatal total bilirubin by trace blood gas analyzer basically meets the clinical requirements and can be used for the preliminary screening of neonatal jaundice. However, for severe hyperbilirubinemia that requires close monitoring of dynamics, a precise enzymatic quantification is required.
引用
收藏
页码:3175 / 3183
页数:9
相关论文
共 50 条
  • [32] ANALYTICAL PERFORMANCE EVALUATION OF THE ALLHEM ANALYZER USED FOR CAPILLARY BLOOD HEMOGLOBIN MEASUREMENTS IN BLOOD DONORS
    Kapusta, M.
    Solnica, B.
    Nalepa, T.
    Kusnierz-Cabala, B.
    Fedak, D.
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2011, 49 : S472 - S472
  • [33] Analytical and clinical validation of the 25 OH vitamin D assay for the LIAISON® automated analyzer
    Ersfeld, DL
    Rao, DS
    Body, JJ
    Sackrison, JL
    Miller, AB
    Parikh, N
    Eskridge, TL
    Polinske, A
    Olson, GT
    MacFarlane, GD
    CLINICAL BIOCHEMISTRY, 2004, 37 (10) : 867 - 874
  • [34] Neonatal CSF glucose measured by blood gas analyzer, glucometer, and standard laboratory methods
    Jain, Abhinay
    Dutta, Sourabh
    Pal, Arnab
    Kumar, Praveen
    JOURNAL OF PERINATOLOGY, 2024, 44 (12) : 1795 - 1799
  • [35] TEMPERATURE-VARIATION DETECTION IN A BLOOD PH-GAS ANALYZER
    DURST, RA
    CLINICAL CHEMISTRY, 1975, 21 (01) : 176 - 177
  • [36] Neonatal hemoglobin affects the accuracy of whole blood bilirubin measurement on GEM Premier 4000 blood gas analyzers
    Huang, Yun
    Dean, Robert
    Dubbelman, Yvonne
    Vincent, Anne
    Khurshid, Faiza
    PRACTICAL LABORATORY MEDICINE, 2021, 25
  • [37] Measurement of anesthetics in blood using a conventional infrared clinical gas analyzer
    Peyton, Philip J.
    Chong, Michael
    Stuart-Andrews, Christopher
    Robinson, Gavin J. B.
    Pierce, Robert
    Thompson, Bruce R.
    ANESTHESIA AND ANALGESIA, 2007, 105 (03): : 680 - 687
  • [38] Analitical performance of the Blood Gas Analyzer:: IL GEM® Premier 3000
    Ilic, M
    Stankovic, S
    Majkic-Singh, N
    CLINICAL CHEMISTRY, 2005, 51 : A32 - A32
  • [39] PERFORMANCE OF GEM PREMIER BLOOD-GAS ELECTROLYTE ANALYZER EVALUATED
    JACOBS, E
    NOWAKOWSKI, M
    COLMAN, N
    CLINICAL CHEMISTRY, 1993, 39 (09) : 1890 - 1893
  • [40] Analytical and clinical validation of a blood progranulin ELISA in frontotemporal dementias
    Meda, Francisco
    Simren, Joel
    Borroni, Barbara
    Cantoni, Valentina
    Archetti, Silvana
    Biasiotto, Giorgio
    Andreasson, Ulf
    Blennow, Kaj
    Kvartsberg, Hlin
    Zetterberg, Henrik
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2023, 61 (12) : 2195 - 2204