Transcatheter aortic valve implantation in pure aortic regurgitation: Hemodynamic and echocardiographic findings in bioprosthesis vs. native valve

被引:6
|
作者
Paraggio, Lazzaro [1 ,2 ]
Burzotta, Francesco [1 ,2 ]
Graziani, Francesca [1 ]
Aurigemma, Cristina [1 ]
Romagnoli, Enrico [1 ]
Pedicino, Daniela [1 ]
Locorotondo, Gabriella [1 ]
Mencarelli, Erica [1 ,2 ]
Lillo, Rosa [1 ,2 ]
Bruno, Piergiorgio [1 ,2 ]
Laezza, Domenico [1 ]
Giambusso, Nicole [1 ]
Lombardo, Antonella [1 ,2 ]
Trani, Carlo [1 ,2 ]
机构
[1] Fdn Policlin Univ A Gemelli IRCCS, Inst Cardiol, Rome, Italy
[2] Univ Cattolica Sacro Cuore, Rome, Italy
关键词
aortic regurgitation; native valve; reverse remodeling; TAVI; TAVR; valve-in-valve; IN-HOSPITAL MORTALITY; VALVULAR REGURGITATION; EUROPEAN ASSOCIATION; AMERICAN SOCIETY; REPLACEMENT; RECOMMENDATIONS; STENOSIS;
D O I
10.1002/ccd.30082
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective The objective of this study is to compare hemodynamic and echocardiographic findings between valve-in-valve (VIV) and native-valve (NV) patients submitted to transcatheter aortic valve implantation (TAVI) due to pure aortic regurgitation (AR). Background Patients with severe AR are surgically treated with variable postinterventional left-ventricular (LV) "reverse remodeling." TAVI might be considered in selected AR patients. Methods Twenty-eight patients with pure severe AR caused by either degenerated bioprosthesis or NV disease were successfully treated by TAVI at our institution. LV catheterization before and after TAVI and echocardiography before, after (24-72 h), and at follow-up (3-12 months) were performed. Results Baseline clinical, hemodynamic, and echocardiographic characteristics were comparable between the two study groups, except for a younger age, higher proto-diastolic LV pressure, and higher LV end-systolic diameter in the NV group. At catheterization, an immediate hemodynamic impact of TAVI in both groups was noticed, with a trend toward better postprocedural residual regurgitation index and significantly lower LV dP/dT values (666.0 +/- 177.9 vs. 883.5 +/- 259.7 mmHg/s, p = 0.04) in VIV. At echocardiography, both NV and VIV patients showed favorable (early and sustained) post-TAVI echocardiographically detectable reverse remodeling. VIV patients also showed more pronounced early reduction in indexed LV end-diastolic volume (68.1 +/- 27.4 vs. 86.5 +/- 28.9 ml/m(2) in VIV, p < 0.001 and 81.0 +/- 29.0 vs. 95.2 +/- 37.8 ml/m(2) in NV, p = 0.043). Conclusions Successful TAVI induces a striking hemodynamic impact with major structural (reverse remodeling) consequences in patients with pure AR caused by both bioprosthesis degeneration or NV disease. In the immediate postrelease phase, VIV patients might exhibit a more pronounced early LV contractile and structural benefit.
引用
收藏
页码:1599 / 1608
页数:10
相关论文
共 50 条
  • [31] Valve-in-valve transcatheter aortic valve implantation after failed surgically implanted aortic bioprosthesis versus native transcatheter aortic valve implantation for aortic stenosis: Data from a nationwide analysis
    Deharo, Pierre
    Bisson, Arnaud
    Herbert, Julien
    Lacour, Thibaud
    Saint Etienne, Christophe
    Jaussaud, Nicolas
    Theron, Alexis
    Collart, Frederic
    Bourguignon, Thierry
    Cuisset, Thomas
    Fauchier, Laurent
    ARCHIVES OF CARDIOVASCULAR DISEASES, 2021, 114 (01) : 41 - 50
  • [32] Transcatheter Aortic Valve Implantation and Atrioventricular Valve Regurgitation
    Isbir, Selim C.
    Birkan, Yasar
    ANNALS OF THORACIC SURGERY, 2013, 96 (04): : 1531 - 1531
  • [33] Direct aortic transcatheter aortic valve implantation for pure aortic valve regurgitation after implantation of a left ventricular assist device
    Krause, Rene
    Metz, Dietrich
    Bushnaq, Hasan
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2014, 147 (04): : E38 - E41
  • [34] Aortic regurgitation after transcatheter aortic valve implantation
    Costopoulos, Charis
    Naganuma, Toru
    Latib, Azeem
    Colombo, Antonio
    EXPERT REVIEW OF CARDIOVASCULAR THERAPY, 2013, 11 (09) : 1089 - 1092
  • [35] Clinical impact of patients with pure native aortic valve regurgitation undergoing transcatheter aortic valve replacement
    Munoz-Garcia, E.
    Munoz-Garcia, M.
    Antonio Jesus Munoz Garcia, A. J.
    Dominguez-Franco, A. J.
    Garcia-Pinilla, J. M.
    Morcillo-Hidalgo, L.
    Jimenez-Navarro, M. F.
    Alonso-Briales, J. H.
    Hernandez-Garcia, J. M.
    De Teresa-Galvan, E.
    EUROPEAN JOURNAL OF HEART FAILURE, 2017, 19 : 453 - 453
  • [36] Challenges in transcatheter valve treatment: aortic regurgitation after transcatheter aortic valve implantation
    Sinning, Jan-Malte
    Werner, Nikos
    Nickenig, Georg
    Grube, Eberhard
    EUROINTERVENTION, 2013, 9 : S72 - S76
  • [37] Improvement of Mitral Regurgitation after Transapical Transcatheter Aortic Valve Bioprosthesis Implantation
    Heraldo G Lobo Filho
    José Glauco Lobo Filho
    Nathalia RP Sousa
    Matheus D Pimentel
    Camylla S Souza
    Journal of Cardiothoracic Surgery, 10 (Suppl 1)
  • [38] Rescue Valve-in-Valve Transcatheter Aortic Valve Replacement for Pure Aortic Regurgitation
    Kaneko, Hidehiro
    Hoelschermann, Frank
    Tambor, Grit
    Neuss, Michael
    Butter, Christian
    JACC-CARDIOVASCULAR INTERVENTIONS, 2017, 10 (03) : E23 - E24
  • [39] Early Hemodynamic and Structural Impact of Transcatheter Aortic Valve Replacement in Pure Aortic Regurgitation
    Graziani, Francesca
    Mencarelli, Erica
    Burzotta, Francesco
    Paraggio, Lazzaro
    Aurigemma, Cristina
    Romagnoli, Enrico
    Pedicino, Daniela
    Locorotondo, Gabriella
    Lombardo, Antonella
    Leone, Antonio Maria
    Laezza, Domenico
    Crea, Filippo
    Trani, Carlo
    JACC-CARDIOVASCULAR INTERVENTIONS, 2020, 13 (21) : 2582 - 2584
  • [40] Transcatheter aortic valve implantation for the treatment of pure aortic valve insufficiency
    Casenghi, Matteo
    Poletti, Enrico
    Rubbio, Antonio Popolo
    Brambilla, Nedy
    Testa, Luca
    Bedogni, Francesco
    De Marco, Federico
    GIORNALE ITALIANO DI CARDIOLOGIA, 2021, 22 (09) : 21S - 28S