Indoor air quality during sleep under different ventilation patterns

被引:76
|
作者
Canha, Nuno [1 ,2 ]
Lage, Joana [1 ]
Candeias, Susana [1 ,3 ]
Alves, Celia [2 ]
Almeida, Susana Marta [1 ]
机构
[1] Univ Lisbon, Inst Super Tecn, Ctr Ciencias & Tecnol Nucl, Estr Nacl 10,Km 139-7, P-2695066 Bobadela, Lrs, Portugal
[2] Univ Aveiro, Dept Environm & Planning, CESAM Ctr Environm & Marine Studies, P-3810193 Aveiro, Portugal
[3] Univ Nova Lisboa, Fac Ciencias & Tecnol, Lisbon, Portugal
关键词
Indoor air quality; Sleep; Exposure; Indoor pollutants; Ventilation; OUTDOOR RELATIONSHIPS; PARTICULATE MATTER; PHYSICAL-ACTIVITY; EXPOSURE; POLLUTANTS; SCHOOLS; BEDROOM; HEALTH; RATES; CHILDREN;
D O I
10.1016/j.apr.2017.05.004
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Sleep plays a crucial role in the human welfare. This preliminary study aimed to characterise the indoor air quality (IAQ) during sleep, which has been scarcely studied, to better understand the occupant's exposure. Comfort parameters along with indoor air pollutants were assessed in one bedroom during the sleeping period of the occupant. Four scenarios of natural ventilation in the bedroom were studied regarding IAQ. The ventilation setting with door and window closed (CDCW) promoted the lowest air change rate (0.67 +/- 0.28 h(-1)) and the highest levels of carbon dioxide (CO2), carbon monoxide (CO) and volatile organic compounds (VOCs). Irrespective of ventilation condition, particulate matter levels (PM10, PM2.5) were always high, although maximum values were recorded under CDCW. The simultaneous opening of door and window supplied the highest air change rate (4.85 +/- 0.57 h(-1)). Several pollutants were found to be in concentrations above the established Portuguese guideline for assuring IAQ, namely VOCs, formaldehyde and PM2.5, in specific ventilation settings. (C) 2017 Turkish National Committee for Air Pollution Research and Control. Production and hosting by Elsevier B.V. All rights reserved.
引用
收藏
页码:1132 / 1142
页数:11
相关论文
共 50 条
  • [31] A numerical study of indoor air quality in a ventilated room using different strategies of ventilation
    Koufi, L.
    Younsi, Z.
    Cherif, Y.
    Naji, H.
    El Ganaoui, M.
    MECHANICS & INDUSTRY, 2017, 18 (02)
  • [32] INDOOR AIR-QUALITY AND HEALTH IN 2 OFFICE BUILDINGS WITH DIFFERENT VENTILATION SYSTEMS
    HEDGE, A
    STERLING, TD
    STERLING, EM
    COLLETT, CW
    STERLING, DA
    NIE, V
    ENVIRONMENT INTERNATIONAL, 1989, 15 (1-6) : 115 - 128
  • [33] INDOOR AIR-QUALITY IN 3 SMALL HOUSING FLATS WITH DIFFERENT VENTILATION SYSTEMS
    REPONEN, T
    KOKOTTI, H
    SAVOLAINEN, T
    RAUNEMAA, T
    JOURNAL OF AEROSOL SCIENCE, 1987, 18 (06) : 701 - 704
  • [34] Editorial - Ventilation and indoor air quality in residential dwellings
    Zhang, Tengfei
    Pei, Jingjing
    BUILDING AND ENVIRONMENT, 2019, 148 : 198 - 199
  • [35] Ventilation for good indoor air quality and energy efficiency
    Awbi, Hazim B.
    SUSTAINABLE SOLUTIONS FOR ENERGY AND ENVIRONMENT, EENVIRO 2016, 2017, 112 : 277 - 286
  • [36] INDOOR AIR-QUALITY AND MINIMUM VENTILATION RATE
    HUBER, G
    WANNER, HU
    ZENTRALBLATT FUR BAKTERIOLOGIE MIKROBIOLOGIE UND HYGIENE SERIE B-UMWELTHYGIENE KRANKENHAUSHYGIENE ARBEITSHYGIENE PRAVENTIVE MEDIZIN, 1983, 177 (06): : 571 - 571
  • [37] Improving indoor air quality by increased ventilation effectiveness
    Rojeski, Jr., Peter
    Journal of Architectural Engineering, 1999, 5 (01) : 25 - 29
  • [38] INDOOR AIR-QUALITY AND MINIMUM VENTILATION RATE
    HUBER, G
    WANNER, HU
    ENVIRONMENT INTERNATIONAL, 1983, 9 (02) : 153 - 156
  • [39] Relationships between ventilation and indoor air quality: A review
    Godish, T
    Spengler, JD
    INDOOR AIR, 1996, 6 (02) : 135 - 145
  • [40] Ventilation to maintain indoor air quality in smoking rooms
    Snelson, D. G.
    Al-Madfai, H.
    Geens, A. J.
    AIR POLLUTION XVIII, 2010, 136 : 339 - 348