Thermoeconomic analysis on a cascade energy utilization system for compression heat in air separation units

被引:27
|
作者
Rong, Yangyiming [1 ]
Zhi, Xiaoqin [1 ]
Wang, Kai [1 ]
Zhou, Xia [1 ]
Cheng, Xingwang [1 ]
Qiu, Limin [1 ]
Chi, Xuelin [2 ]
机构
[1] Zhejiang Univ, Inst Refrigerat & Cryogen, Hangzhou 310027, Peoples R China
[2] Hangzhou Oxygen Plant Grp Co Ltd, Hangzhou 310014, Peoples R China
基金
中国国家自然科学基金; 国家重点研发计划;
关键词
Compression heat; Liquid desiccant dehumidification; Organic Rankine vapor compression; Cryogenic air separation unit; NATURAL-GAS LNG; CENTRIFUGAL-COMPRESSOR; EXERGY ANALYSIS; OPTIMAL-DESIGN; CO2; CAPTURE; POWER-PLANT; INTEGRATION; OPTIMIZATION; TECHNOLOGIES; PERFORMANCE;
D O I
10.1016/j.enconman.2020.112820
中图分类号
O414.1 [热力学];
学科分类号
摘要
The performance of air compression is crucial to the overall efficiency of cryogenic air separation units. A cascade utilization system of compression heat (CUSCH) is proposed for air separation units, in which the compression heat is used in situ to improve the operating condition of the compressor through inlet air cooling and dehumidification. The compression heat of relatively higher-grade (> 75 degrees C) is used to drive an organic Rankine vapor compression (ORVC) refrigeration cycle for air cooling, while the remaining lower-grade heat (40-75 degrees C) is used to regenerate the desiccant solution for the dehumidification system. A thermodynamic model is built for the CUSCH and a case study is conducted based on a practical compression process for a 60,000-Nm(3)/ h scale air separation unit. The influences of air dehumidification and cooling on the compression performance are analyzed. The results indicate that the CUSCH not only reduces the compression power but also prevents water condensation in the compressors and heat exchangers, which is beneficial for operational safety. It is estimated that the proposed CUSCH can reduce about 4.9% of the total compression power, and the isothermal efficiency of air compressor is increased by about 5.0%. In addition, the CUSCH is economically viable and environmentally friendly compared with traditional compression systems, with a payback time of 5.0 years, a levelized cost of energy of 0.0339 $/kWh, and a CO2 emission reduction potential of 6340 tCO(2)/year, which shows its prospects for practical applications in particular for large scale air separation units.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Potential for Energy Utilization of Air Compression Section Using an Open Absorption Refrigeration System
    Ye, Bicui
    Sun, Shufei
    Wang, Zheng
    APPLIED SCIENCES-BASEL, 2022, 12 (13):
  • [32] Energy and Exergy Analysis, and Thermoeconomic Performance of a BCHP System
    曹家枞
    刘凤强
    秦志红
    曹双华
    张时飞
    Journal of Donghua University(English Edition), 2004, (05) : 36 - 42
  • [33] Thermoeconomic analysis of a CO2 compression system using waste heat into the regenerative organic Rankine cycle
    Kurtulus, Karani
    Coskun, Ahmet
    Ameen, Shadan
    Yilmaz, Ceyhun
    Bolatturk, Ali
    ENERGY CONVERSION AND MANAGEMENT, 2018, 168 : 588 - 598
  • [34] THERMOECONOMIC APPROACH TO THE ANALYSIS OF ENERGY SYSTEM CONTROL STRATEGIES
    Verda, Vittorio
    Baccino, Giorgia
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION - 2010, VOL 5, PTS A AND B, 2012, : 619 - 625
  • [36] WASTE UTILIZATION SYSTEM WITH HEAT RECUPERATION AND AIR PREHEATING - EFFICIENCY ANALYSIS
    Bujak, Janusz
    ENVIRONMENT PROTECTION ENGINEERING, 2009, 35 (04): : 93 - 110
  • [37] Thermodynamic analysis of a hybrid energy system coupling solar organic Rankine cycle and ground source heat pump: Exploring heat cascade utilization
    Chen, Liangqi
    Yue, Huifeng
    Wang, Jiangfeng
    Lou, Juwei
    Wang, Shunsen
    Guo, Yumin
    Deng, Bohao
    Sun, Lu
    ENERGY, 2023, 284
  • [38] Thermoeconomic analysis of a building energy system integrated with energy storage options
    Caliskan, Hakan
    Dincer, Ibrahim
    Hepbasli, Arif
    ENERGY CONVERSION AND MANAGEMENT, 2013, 76 : 274 - 281
  • [39] Energy and exergetic analysis of applying solar cascade utilization to an artificial photosynthesis energy supply system
    Kwan, Trevor Hocksun
    Gao, Datong
    Shen, Yongting
    Pei, Gang
    ENERGY CONVERSION AND MANAGEMENT, 2022, 257
  • [40] Energy, entropy and cost analysis of a combined power and water system with cascade utilization of geothermal energy
    He, W. F.
    Han, D.
    Wen, T.
    ENERGY CONVERSION AND MANAGEMENT, 2018, 174 : 719 - 729