Two-Photon Autofluorescence Lifetime and SHG Imaging of Healthy and Diseased Human Corneas

被引:2
|
作者
Batista, Ana [1 ,2 ]
Breunig, Hans Georg [2 ,3 ]
Uchugonova, Aisada [2 ]
Seitz, Berthold [4 ]
Morgado, Antonio Miguel [1 ,5 ]
Koenig, Karsten [2 ,3 ]
机构
[1] Univ Coimbra, Fac Med, Inst Biomed Imaging & Life Sci, Coimbra, Portugal
[2] Univ Saarland, Dept Biophoton & Laser Technol, BLT, Saarbrucken, Germany
[3] JenLab GmbH, Jena, Germany
[4] Univ Saarland, Med Ctr, Dept Ophthalmol, Homburg, Germany
[5] Univ Coimbra, Fac Sci & Technol, Dept Phys, Coimbra, Portugal
来源
OPHTHALMIC TECHNOLOGIES XXV | 2015年 / 9307卷
关键词
Corneal Imaging; Corneal Disease; Fluorescence Lifetime Imaging; Spectral FLIM; Second Harmonic Generation; Two-photon Microscopy; 2ND-HARMONIC GENERATION; CROSS-LINKING; FLUORESCENCE; MICROSCOPY;
D O I
10.1117/12.2077569
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Corneal function can be drastically affected by several degenerations and dystrophies, leading to blindness. Early diagnosis of corneal disease is of major importance and it may be accomplished by monitoring changes of the metabolic state and structural organization, the first detectable pathological signs, by two-photon excitation autofluorescence lifetime and second-harmonic generation imaging. In this study, we propose to use these imaging techniques to differentiate between healthy and pathological corneas. Images were acquired using a laser-scanning microscope with a broadband sub-15 femtosecond near-infrared pulsed laser and a 16-channel photomultiplier tube detector for signal collection. This setup allows the simultaneous excitation of metabolic co-factors and to identify them based on their fluorescence spectra. We were able to discriminate between healthy and pathological corneas using two-photon excitation autofluorescence lifetime and second-harmonic generation imaging from corneal epithelium and stroma. Furthermore, differences between different pathologies were observed. Alterations in the metabolic state of corneal epithelial cells were observed using the autofluorescence lifetime of the metabolic co-factors. In the corneal stroma, we observed not only alterations in the collagen fibril structural organization but also alterations in the autofluorescence lifetime. Further tests are required as the number of pathological samples must be increased. In the future, we intend to establish a correlation between the metabolic and structural changes and the disease stage. This can be a step forward in achieving early diagnosis.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Early evaluation of corneal collagen crosslinking in ex-vivo human corneas using two-photon imaging
    Batista, Ana
    Breunig, Hans Georg
    Hager, Tobias
    Seitz, Berthold
    Koenig, Karsten
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [32] Early evaluation of corneal collagen crosslinking in ex-vivo human corneas using two-photon imaging
    Ana Batista
    Hans Georg Breunig
    Tobias Hager
    Berthold Seitz
    Karsten König
    Scientific Reports, 9
  • [33] Two-photon imaging
    Rachel Won
    Nature Photonics, 2016, 10 (2) : 73 - 73
  • [34] Photon counting, censor corrections, and lifetime imaging for improved detection in two-photon microscopy
    Driscoll, Jonathan D.
    Shih, Andy Y.
    Iyengar, Satish
    Field, Jeffrey J.
    White, G. Allen
    Squier, Jeffrey A.
    Cauwenberghs, Gert
    Kleinfeld, David
    JOURNAL OF NEUROPHYSIOLOGY, 2011, 105 (06) : 3106 - 3113
  • [35] Functional Imaging of Ex Vivo Human Corneal Endothelium Using Two-Photon Fluorescence Lifetime Imaging Microscopy
    Zhu, Dagny
    Arnesano, Cosimo
    Do, Jiun Lap
    Shih, Grace
    Cao, Jessica
    Fraser, Scott
    Heur, Martin
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [36] Applications of Two-Photon Excitation Fluorescence Lifetime Imaging in Tumor Diagnosis
    Li Hui
    Xia Xianyuan
    Chen Tingai
    Yu Jia
    Li Xi
    Zheng Wei
    CHINESE JOURNAL OF LASERS-ZHONGGUO JIGUANG, 2018, 45 (02):
  • [37] Two-Photon Fluorescence Lifetime Imaging for Metabolic Profiling of Cochlear Dysfunction
    Zholudeva, Lyandysha V.
    Ward, Kristina G.
    Nichols, Michael G.
    Smith, Heather Jensen
    BIOPHYSICAL JOURNAL, 2014, 106 (02) : 185A - 185A
  • [38] Towards two-photon excited endogenous fluorescence lifetime imaging microendoscopy
    Hage, C. H.
    Leclerc, P.
    Brevier, J.
    Fabert, M.
    Le Nezet, C.
    Kudlinski, A.
    Heliot, L.
    Louradour, F.
    BIOMEDICAL OPTICS EXPRESS, 2018, 9 (01): : 142 - 156
  • [39] Repeatability of wide -field autofluorescence lifetime imaging at the human retina in healthy volunteers
    Klemm, M.
    Dietzel, A.
    Nagel, E.
    Schweitzer, D.
    ACTA OPHTHALMOLOGICA, 2015, 93
  • [40] Two-Photon Phosphorescence Lifetime Microscopy
    Abbasizadeh, Nastaran
    Spencer, Joel A.
    OPTICAL IMAGING IN HUMAN DISEASE AND BIOLOGICAL RESEARCH, 2021, 1355 : 63 - 82