Interruption characteristics of double-break vacuum circuit breakers

被引:51
|
作者
Ide, Naotaka [1 ]
Tanaka, Osamu [1 ]
Yanabu, Satoru [1 ]
Kaneko, Shuhei [2 ]
Okabe, Shigemitsu [2 ]
Matsui, Yoshihiko [3 ]
机构
[1] Tokyo Denki Univ, Dept Elect Engn, Chiyoda Ku, Tokyo 101, Japan
[2] Tokyo Elect Power Co Ltd, Tsurumi Ku, Kanagawa, Japan
[3] Japan AE Power Syst Co, Shizuoka, Japan
关键词
double-break; grading capacitors; post arc current; vacuum circuit breakers; vacuum interrupters; voltage distribution ratio;
D O I
10.1109/TDEI.2008.4591229
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Since the majority of vacuum circuit breakers in use are of the single-break variety, there have been few studies of double-break vacuum circuit breakers. This report describes our investigations of the interruption characteristics of the double-break vacuum circuit breaker. In this investigation, the post arc current and recovery voltage distribution ratio were measured in order to clarify the relationship between them. The results show that a bias of the voltage distribution ratio occurs when the post arc current value becomes imbalanced. In addition, the measurements of the post arc current for circuit breakers with spiral contacts are very scattered as compared with those with axial magnetic field contacts. Normally, the double-break vacuum circuit breaker consists of two contacts of the same type. However, when two spiral contacts are used, the scattering of post arc current causes a current imbalance. As a result, a bias of the voltage distribution ratio may occur. It appears to be preferable to use double-break vacuum circuit breakers with axial magnetic field contacts.
引用
收藏
页码:1065 / 1072
页数:8
相关论文
共 50 条
  • [1] Capacitive making of vacuum circuit breakers: Double-break vacuum circuit breaker is superior to single-break vacuum circuit breaker
    Geng, Yun
    Zhang, Jun
    Yao, Xiaofei
    Fan, Jun
    Jin, Qingbin
    Geng, Yingsan
    Liu, Zhiyuan
    [J]. ELECTRIC POWER SYSTEMS RESEARCH, 2022, 204
  • [2] Influence of bias magnetic field on the vacuum arc in double-break vacuum circuit breakers
    Liao, Minfu
    Qiao, Shuzhen
    Lu, Gang
    Ge, Guowei
    Zou, Jiyan
    [J]. CONTRIBUTIONS TO PLASMA PHYSICS, 2018, 58 (04) : 282 - 292
  • [4] Influence of Dynamic Charge Compensation on Voltage Distribution of Double-Break Vacuum Circuit Breakers
    Cheng, Xian
    Du, Shuai
    Ge, Guowei
    Chen, Hui
    Bai, Qinglin
    [J]. IEEE TRANSACTIONS ON PLASMA SCIENCE, 2024, 52 (02) : 488 - 495
  • [5] Prestrike Characteristics of Double-Break Vacuum Circuit Breakers with Asynchronous closing operations under DC Voltages
    Chen, Xinggui
    Geng, Yun
    Yao, Xiaofei
    Zhang, Luyang
    Huang, Jincai
    Liu, Zhiyuan
    Geng, Yingsan
    Wang, Jianhua
    [J]. 29TH INTERNATIONAL SYMPOSIUM ON DISCHARGES AND ELECTRICAL INSULATION IN VACUUM (ISDEIV 2020), 2021, : 73 - 76
  • [6] Research on Voltage Distribution of Double-Break Vacuum Circuit Breakers with Different Interrupters in Series
    Xiang, Zhen
    Zhang, Xin
    Huang, Ronghui
    Wu, Zhiheng
    Liao, Minfu
    Zhang, Xiaoli
    [J]. PROCEEDINGS OF THE 2018 28TH INTERNATIONAL SYMPOSIUM ON DISCHARGES AND ELECTRICAL INSULATION IN VACUUM (ISDEIV 2018), VOL 2, 2018, : 635 - 638
  • [7] Experimental Investigation on the Matching Characteristics of Vacuum Circuit Breaker with Double-break
    Ge, Guowei
    Liao, Minfu
    Duan, Xiongying
    Wang, Shanjun
    Cheng, Xian
    Zou, Jiyan
    [J]. PROCEEDINGS OF THE 2014 26TH INTERNATIONAL SYMPOSIUM ON DISCHARGES AND ELECTRICAL INSULATION IN VACUUM (ISDEIV-2014), 2014, : 493 - 496
  • [8] Study on Short-circuit current interruption characteristics of Double-break fast vacuum circuit breaker within the minimum arcing time
    Guan, Chen
    Ding, Jiangang
    Yao, Xiaofei
    Zheng, Jiaming
    Mu, Shengquan
    Liu, Zhiyuan
    Wang, Jianhua
    Geng, Yingsan
    [J]. INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2023, 147
  • [9] The Relations between the Voltage Distribution Ratio and the Post Arc Current in Double-Break Vacuum Circuit Breakers
    Sugita, M.
    Tanaka, O.
    Kasuya, H.
    Igarashi, T.
    Okabe, S.
    Ueta, G.
    Matsui, Y.
    van Lanen, E.
    Yanabu, S.
    [J]. ISDEIV 2008: PROCEEDINGS OF THE XXIIIRD INTERNATIONAL SYMPOSIUM ON DISCHARGES AND ELECTRICAL INSULATION IN VACUUM, VOLS 1 AND 2, 2008, : 251 - +
  • [10] Relationship Between the Voltage Distribution Ratio and the Post Arc Current in Double-Break Vacuum Circuit Breakers
    Sugita, Masanori
    Igarashi, Tetsuo
    Kasuya, Hiroaki
    Okabe, Shigemitsu
    Matsui, Yoshihiko
    van Lanen, Ezra
    Yanabu, Satoru
    [J]. IEEE TRANSACTIONS ON PLASMA SCIENCE, 2009, 37 (08) : 1438 - 1445