Projection decomposition via univariate optimization for dual-energy CT

被引:3
|
作者
Cong, Wenxiang [1 ]
De Man, Bruno [2 ]
Wang, Ge [1 ]
机构
[1] Rensselaer Polytech Inst, Biomed Imaging Ctr, Dept Biomed Engn, Troy, NY 12180 USA
[2] GE Res, One Res Circle, Niskayuna, NY USA
基金
美国国家卫生研究院;
关键词
Dual-energy computed tomography (DECT); polychromatic physical model; projection decomposition; material decomposition; monochromatic image reconstruction; NETWORK;
D O I
10.3233/XST-221153
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Dual-energy computed tomography (DECT) acquires two x-ray projection datasets with different x-ray energy spectra, performs material-specific image reconstruction based on the energy-dependent non-linear integral model, and provides more accurate quantification of attenuation coefficients than single energy spectrum CT. In the diagnostic energy range, x-ray energy-dependent attenuation is mainly caused by photoelectric absorption and Compton scattering. Theoretically, these two physical components of the x-ray attenuation mechanism can be determined from two projection datasets with distinct energy spectra. Practically, the solution of the non-linear integral equation is complicated due to spectral uncertainty, detector sensitivity, and data noise. Conventional multivariable optimization methods are prone to local minima. In this paper, we develop a new method for DECT image reconstruction in the projection domain. This method combines an analytic solution of a polynomial equation and a univariate optimization to solve the polychromatic non-linear integral equation. The polynomial equation of an odd order has a unique real solution with sufficient accuracy for image reconstruction, and the univariate optimization can achieve the global optimal solution, allowing accurate and stable projection decomposition for DECT. Numerical and physical phantom experiments are performed to demonstrate the effectiveness of the method in comparison with the state-of-the-art projection decomposition methods. As a result, the univariate optimization method yields a quality improvement of 15% for image reconstruction and substantial reduction of the computational time, as compared to the multivariable optimization methods.
引用
收藏
页码:725 / 736
页数:12
相关论文
共 50 条
  • [31] Dual-Energy CT of the Lung
    Lu, Guang Ming
    Zhao, Yan'E
    Zhang, Long Jiang
    Schoepf, U. Joseph
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (05) : S40 - S53
  • [32] Nonuniqueness in dual-energy CT
    Levine, Zachary H.
    MEDICAL PHYSICS, 2017, 44 (09) : E202 - E206
  • [33] Dual-Energy CT of the Heart
    Vliegenthart, Rozemarijn
    Pelgrim, Gert Jan
    Ebersberger, Ullrich
    Rowe, Garrett W.
    Oudkerk, Matthijs
    Schoepf, U. Joseph
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (05) : S54 - S63
  • [34] Material decomposition with a prototype photon-counting detector CT system: expanding a stoichiometric dual-energy CT method via energy bin optimization and K-edge imaging
    Richtsmeier, Devon
    Rodesch, Pierre-Antoine
    Iniewski, Kris
    Bazalova-Carter, Magdalena
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (05):
  • [35] A Flexible Method for Multi-Material Decomposition of Dual-Energy CT Images
    Mendonca, Paulo R. S.
    Lamb, Peter
    Sahani, Dushyant V.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2014, 33 (01) : 99 - 116
  • [36] CT Dual-energy Decomposition into X-ray Signatures ρe and Ze
    Martz, Harry E., Jr.
    Seetho, Isaac M.
    Champley, Kyle M.
    Smith, Jerel A.
    Azevedo, Stephen G.
    ANOMALY DETECTION AND IMAGING WITH X-RAYS (ADIX), 2016, 9847
  • [37] Dual-Energy CT for Diagnostic CT Colonography
    Karcaaltincaba, Musturay
    Ozdeniz, Ilknur
    RADIOGRAPHICS, 2014, 34 (03) : 847 - 847
  • [38] Numerical Simulation for Basis Material Decomposition and Image Reconstruction of Dual-energy CT
    He, Fangfang
    Sun, Fengrong
    Wang, Naishun
    Wu, Lijun
    Babyn, Paul
    Yao, Guihua
    Zhong, Hai
    PROCEEDINGS OF 2019 IEEE 3RD INFORMATION TECHNOLOGY, NETWORKING, ELECTRONIC AND AUTOMATION CONTROL CONFERENCE (ITNEC 2019), 2019, : 1314 - 1318
  • [39] Noise reduction in direct multi-material decomposition for dual-energy CT
    Lee, Haenghwa
    Lee, Dong-Hoon
    Jeon, Pil-Hyun
    Chao, Zhen
    Kim, Hee-Joung
    INTERNATIONAL WORKSHOP ON ADVANCED IMAGING TECHNOLOGY (IWAIT) 2020, 2020, 11515
  • [40] Noise Suppression in Image-Domain Multimaterial Decomposition for Dual-Energy CT
    Jiang, Y.
    Xue, Y.
    Yang, P.
    Xu, L.
    Luo, C.
    Yang, C.
    Niu, T.
    MEDICAL PHYSICS, 2019, 46 (06) : E408 - E408