The Effects of Bit Wear on Respirable Silica Dust, Noise and Productivity: A Hammer Drill Bench Study

被引:10
|
作者
Carty, Paul [1 ]
Cooper, Michael R. [2 ]
Barr, Alan [2 ]
Neitzel, Richard L. [3 ]
Balmes, John [1 ,4 ]
Rempel, David [1 ,2 ,4 ]
机构
[1] Univ Calif Berkeley, Sch Publ Hlth, Berkeley, CA 94720 USA
[2] Univ Calif Berkeley, Dept Bioengn, Berkeley, CA 94720 USA
[3] Univ Michigan, Dept Environm Hlth Sci, Ann Arbor, MI 48109 USA
[4] Univ Calif San Francisco, Dept Med, San Francisco, CA 94143 USA
关键词
concrete drilling; dust concentration; masonry; noise level; tool wear; ENERGY NUCLEAR SITES; TRADE WORKERS; CONSTRUCTION; EXPOSURE; CONCRETE; SURVEILLANCE; TOOLS;
D O I
10.1093/annweh/wxx041
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Objectives: Hammer drills are used extensively in commercial construction for drilling into concrete for tasks including rebar installation for structural upgrades and anchor bolt installation. This drilling task can expose workers to respirable silica dust and noise. The aim of this pilot study was to evaluate the effects of bit wear on respirable silica dust, noise, and drilling productivity. Method: Test bits were worn to three states by drilling consecutive holes to different cumulative drilling depths: 0, 780, and 1560 cm. Each state of bit wear was evaluated by three trials (nine trials total). For each trial, an automated laboratory test bench system drilled 41 holes 1.3 cm diameter, and 10 cm deep into concrete block at a rate of one hole per minute using a commercially available hammer drill and masonry bits. During each trial, dust was continuously captured by two respirable and one inhalable sampling trains and noise was sampled with a noise dosimeter. The room was thoroughly cleaned between trials. Results: When comparing results for the sharp (0 cm) versus dull bit (1560 cm), the mean respirable silica increased from 0.41 to 0.74 mg m(-3) in sampler 1 (P = 0.012) and from 0.41 to 0.89 mg m(-3) in sampler 2 (P = 0.024); levels above the NIOSH recommended exposure limit of 0.05 mg m(-3). Likewise, mean noise levels increased from 112.8 to 114.4 dBA (P < 0.00001). Drilling productivity declined with increasing wear from 10.16 to 7.76 mm s(-1) (P < 0.00001). Discussion: Increasing bit wear was associated with increasing respirable silica dust and noise and reduced drilling productivity. The levels of dust and noise produced by these experimental conditions would require dust capture, hearing protection, and possibly respiratory protection. The findings support the adoption of a bit replacement program by construction contractors.
引用
下载
收藏
页码:700 / 710
页数:11
相关论文
共 22 条
  • [21] Effects of cooling position on tool wear reduction of secondary cutting edge corner of one-shot drill bit in drilling CFRP
    Wang, Fuji
    Qian, Baowei
    Jia, Zhenyuan
    Cheng, De
    Fu, Rao
    INTERNATIONAL JOURNAL OF ADVANCED MANUFACTURING TECHNOLOGY, 2018, 94 (9-12): : 4277 - 4287
  • [22] ADDITIVE EFFECTS OF EXPOSURE TO SILICA DUST AND SMOKING ON PULMONARY EPITHELIAL PERMEABILITY - A RADIOAEROSOL STUDY WITH TC-99M LABELED DTPA
    NERY, LE
    FLORENCIO, RT
    SANDOVAL, PRM
    RODRIGUES, RT
    ALONSO, G
    MASON, GR
    THORAX, 1993, 48 (03) : 264 - 268