The effect of the interturn insulation of the rotor winding of a hydroelectric generator on its temperature field

被引:0
|
作者
Veili, L [1 ]
Lyan'tsin', K [1 ]
Zhen'khunlin' [1 ]
Chen'shukan [1 ]
机构
[1] Harbin Tech Univ, Harbin, Peoples R China
来源
关键词
hydroelectric generator; rotor; interturn insulation; temperature field;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The three-dimensional temperature field of the rotor winding of a hydroelectric generator at its hottest section is determined using the finite-element method, and the influence of the interturn insulation on the temperature of the winding is considered.
引用
下载
收藏
页码:82 / 87
页数:6
相关论文
共 50 条
  • [21] Calculation of nonlinear stator temperature field after insulation aging for large generator
    Cheng, Shu-Kang
    Li, Wei-Li
    Zhou, Feng
    Hou, Yun-Peng
    Harbin Gongye Daxue Xuebao/Journal of Harbin Institute of Technology, 2003, 35 (01): : 62 - 65
  • [22] Effect of Temperature on the Characteristics of Frequency Domain Spectroscopy of Generator Stator Insulation
    Yin Xiaobing
    Cao Baojing
    2016 IEEE INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION (ICHVE), 2016,
  • [23] Field simulation studies for a high temperature superconducting synchronous generator with a coreless rotor
    Ship, KS
    Sykulski, JK
    IEE PROCEEDINGS-SCIENCE MEASUREMENT AND TECHNOLOGY, 2004, 151 (06) : 414 - 418
  • [24] Temperature Effect on Insulation Resistance of Generator Stator Bar Affected by Water Ingress
    Petit, Andre
    2015 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2015, : 515 - 518
  • [25] Detection of Turbine Generator Field Winding Serious Inter-Turn Short Circuit Based on the Rotor Vibration Feature
    Huang, Haizhou
    Zhang, Kanjun
    Zhang, Yong
    UPEC: 2009 44TH INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE, 2009, : 478 - +
  • [26] Effect of Ambient Temperature on Insulation Lifetime of Winding Coil Prepared with Polyamideimide/Nanosilica Enamelled Wire
    Park, Jae-Jun
    Woo, Myung-Ha
    Lee, Jae-Young
    Hwang, Don-Ha
    TRANSACTIONS ON ELECTRICAL AND ELECTRONIC MATERIALS, 2016, 17 (05) : 297 - 301
  • [27] Breaking Overvoltage of Dry-Type Air-Core Shunt Reactors and Its Cumulative Effect on the Interturn Insulation
    Nie, Hongyan
    Liu, Xiaosheng
    Wang, Yonghong
    Yao, Yuanhang
    Gu, Zheyi
    Zhang, Chaohai
    IEEE ACCESS, 2019, 7 : 55707 - 55720
  • [28] Influence of Main Insulation Thermal Aging on Stator Temperature Field in Large Turbo-generator
    Li, Wei-li
    Wu, Zhen-xing
    Huo, Fei-yang
    MATERIALS SCIENCE AND INFORMATION TECHNOLOGY, PTS 1-8, 2012, 433-440 : 7505 - +
  • [29] Research on Stator Main Insulation Temperature Field of Air-Cooled Turbo-Generator after Main Insulation Shelling
    Li, Weili
    Li, Yong
    Su, Ying
    Wang, Purui
    Liu, Wenmao
    ENERGIES, 2018, 11 (05)
  • [30] The Research on Temperature Field and Flow Field of Brushless Doubly-Fed Generator With Cage-Barrier Rotor
    Jiang, Xiaodong
    Zhang, Fengge
    Li, Yingguang
    2017 IEEE 26TH INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS (ISIE), 2017, : 381 - 386