On the use of the bio-impedance technique for body composition measurements

被引:0
|
作者
Huerta-Franco, R [1 ]
Vargas-Luna, M [1 ]
González-Solís, JL [1 ]
Gutiérrez-Juárez, G [1 ]
机构
[1] Univ Guanajuato, Inst Fis, Guanajuato 37150, Mexico
来源
MEDICAL PHYSICS | 2003年 / 682卷
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Reviewing the methods and physical principles used in body composition measurements (BCM), it is evident that more accurate, reliable, and easily handled methods are required. The use of bio-impedance analysis (BIA) has been very useful in BCM. This technique, in the single frequency mode, has some commercial versions to perform BCM. However these apparatus have significant variability in the BCM values. The multi-frequency option of the bio-impedance technique has still a lot of challenges to overcome. We studied the variability of the body impedance spectrum (from 1 Hz to 1 MHz) in a group of subjects compared to the values obtained from commercial apparatus. We compared different anatomical body regions, some of them with less subcutaneous body fat (frontal, anterior tibial, knee, and frontal regions); others with more subcutaneous body fat (pectoral, abdominal, and internal calf regions). In order to model the bio-impedance spectrum, we analyzed layered samples with different thickness and material composition.
引用
收藏
页码:61 / 66
页数:6
相关论文
共 50 条
  • [31] Toward Portable Bio-impedance devices
    AboBakr, Ahmed
    Mohsen, Menna
    Said, Lobna A.
    Madian, Ahmed H.
    Elwakil, Ahmed S.
    Radwan, Ahmed G.
    2019 FOURTH INTERNATIONAL CONFERENCE ON ADVANCES IN COMPUTATIONAL TOOLS FOR ENGINEERING APPLICATIONS (ACTEA), 2019,
  • [32] Design of a CMOS closed-loop system with applications to bio-impedance measurements
    Yufera, Alberto
    Rueda, Adoracion
    MICROELECTRONICS JOURNAL, 2010, 41 (04) : 231 - 239
  • [33] ImpediBands: Body Coupled Bio-Impedance Patches for Physiological Sensing Proof of Concept
    Sel, Kaan
    Ibrahim, Bassem
    Jafari, Roozbeh
    IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2020, 14 (04) : 757 - 774
  • [34] Design of Automatic Switching Bio-Impedance Analysis (BIA) for Body Fat Measurement
    Riyadi, Munawar A.
    Muthouwali, Achmad Ngaqib
    Prakoso, Teguh
    2017 4TH INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING, COMPUTER SCIENCE AND INFORMATICS (EECSI), 2017, : 172 - 176
  • [35] An evaluation of the influence of a magnetic field on a human subject with the use of bio-impedance
    Papezova, S.
    Papez, V.
    INTERNATIONAL CONFERENCE ON MAGNETISM (ICM 2009), 2010, 200
  • [36] An Experimental validation of Bio-impedance Technique for medical & non-medical Application
    Kumar, Ramesh
    Kumar, Sharvan
    Bin Queyam, Abdullah
    Sengupta, A.
    PROCEEDINGS OF THE 8TH INTERNATIONAL CONFERENCE CONFLUENCE 2018 ON CLOUD COMPUTING, DATA SCIENCE AND ENGINEERING, 2018, : 354 - 359
  • [37] Proximal and distal measurements of extracellular and total body water by multi-frequency bio-impedance analysis in surgical patients
    Hannan, WJ
    Cowen, SJ
    Plester, C
    Fearon, KCH
    APPLIED RADIATION AND ISOTOPES, 1998, 49 (5-6) : 621 - 622
  • [38] Spectroscopic Study and Analysis of the Impact of Alcohol Intake on Bio-Impedance of the Human Body
    Omura, Yasuhisa
    Kojima, Kazuma
    2011 IEEE SENSORS, 2011, : 1648 - 1651
  • [39] Influence of a magnetic field on changes in bio-impedance
    Papezova, S.
    Papez, V.
    13TH INTERNATIONAL CONFERENCE ON ELECTRICAL BIOIMPEDANCE AND THE 8TH CONFERENCE ON ELECTRICAL IMPEDANCE TOMOGRAPHY 2007, 2007, 17 : 751 - 754
  • [40] The Impedance Property of Electrode Used in Electrical Bio-impedance Measurement
    Gong WeiYan
    Lv JingHua
    Wang Yan
    Sha Hong
    Zhao Shu
    Ren ChaoShi
    2009 3RD INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING, VOLS 1-11, 2009, : 2308 - +