Impact of dead time on quantitative 177Lu-SPECT (QSPECT) and kidney dosimetry during PRRT

被引:11
|
作者
Desy, Alessandro [1 ,2 ,3 ]
Bouvet, Guillaume F. [1 ,2 ,3 ]
Frezza, Andrea [1 ,4 ]
Despres, Philippe [1 ,4 ,5 ]
Beauregard, Jean-Mathieu [1 ,2 ,3 ]
机构
[1] Univ Laval, Canc Res Ctr, Quebec City, PQ, Canada
[2] Univ Laval, Dept Radiol & Nucl Med, Quebec City, PQ, Canada
[3] Univ Laval, CHU Quebec, Dept Med Imaging & Oncol, Div Res Ctr, 11 Cote Palais, Quebec City, PQ G1R 2J6, Canada
[4] Univ Laval, Dept Phys Engn Phys & Opt, Quebec City, PQ, Canada
[5] Univ Laval, CHU Quebec, Dept Radiat Oncol & Oncol, Div Res Ctr, 11 Cote Palais, Quebec City, PQ G1R 2J6, Canada
基金
加拿大健康研究院;
关键词
Dead time; Quantitative SPECT; Dosimetry; Radionuclide therapy; Lu-177; INDIVIDUALIZED DOSIMETRY; OCTREOTATE; THERAPY;
D O I
10.1186/s40658-020-00303-0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Dead time may affect the accuracy of quantitative SPECT (QPSECT), and thus of dosimetry. The aim of this study was to quantify the effect of dead time on Lu-177-QSPECT and renal dosimetry following peptide receptor radionuclide therapy (PRRT) of neuroendocrine tumours. Methods QSPECT/CT was performed on days 1 and 3 during 564 personalized Lu-177-octreotate cycles in 166 patients. The dead-time data for each scanning time point was compiled. The impact of not correcting QSPECT for the dead time was assessed for the kidney dosimetry. This was also estimated for empiric PRRT by simulating in our cohort a regime of 7.4 GBq/cycle. Results The probability to observe a larger dead time increased with the injected activity. A dead-time loss greater than 5% affected 14.4% and 5.7% of QSPECT scans performed at days 1 and 3, respectively. This resulted in renal absorbed dose estimates that would have been underestimated by more than 5% in 5.7% of cycles if no dead-time correction was applied, with a maximum underestimation of 22.1%. In the simulated empiric regime, this potential dose underestimation would have been limited to 6.2%. Conclusion Dead-time correction improves the accuracy of dosimetry in Lu-177 radionuclide therapy and is warranted in personalized PRRT.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Impact of dead time on quantitative 177Lu-SPECT (QSPECT) and kidney dosimetry during PRRT
    Alessandro Desy
    Guillaume F. Bouvet
    Andrea Frezza
    Philippe Després
    Jean-Mathieu Beauregard
    EJNMMI Physics, 7
  • [2] Impact of the dead-time correction method on quantitative 177Lu-SPECT (QSPECT) and dosimetry during radiopharmaceutical therapy
    Alessandro Desy
    Guillaume F. Bouvet
    Nancy Lafrenière
    Atefeh Zamanian
    Philippe Després
    Jean-Mathieu Beauregard
    EJNMMI Physics, 9
  • [3] Impact of the dead-time correction method on quantitative 177Lu-SPECT (QSPECT) and dosimetry during radiopharmaceutical therapy
    Desy, Alessandro
    Bouvet, Guillaume F.
    Lafreniere, Nancy
    Zamanian, Atefeh
    Despres, Philippe
    Beauregard, Jean-Mathieu
    EJNMMI PHYSICS, 2022, 9 (01)
  • [4] Impact of dead-time correction method on 177Lu quantitative SPECT and dosimetry in personalized PRRT
    Desy, A.
    Bouvet, G. F.
    Beauregard, J. M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2021, 48 (SUPPL 1) : S72 - S73
  • [5] Quantitative 177Lu-SPECT (QSPECT) during second cycle predicts 68Ga-octreotate-PET/CT molecular response to 177Lu-octreotate PRRT
    Beauregard, Jean-Mathieu
    Forget, Vincent
    Desy, Alessandro
    Benesty, Ophelie Belissant
    Buteau, Francois-Alexandre
    Beaulieu, Alexis
    Arsenault, Frederic
    April, Genevieve
    Bouvet, Guillaume
    Guerin, Brigitte
    Turcotte, Eric
    JOURNAL OF NUCLEAR MEDICINE, 2020, 61
  • [6] Quantitative 177Lu-SPECT/CT imaging and validation of a commercial dosimetry software
    D'ambrosio, L.
    Aloj, L.
    Madesani, D.
    Morisco, A.
    Aurilio, M.
    Prisco, A.
    Di Gennaro, F.
    Lastoria, S.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2013, 40 : S263 - S263
  • [7] Comprehensive SPECT/CT system characterization and calibration for 177Lu quantitative SPECT (QSPECT) with dead-time correction
    Andrea Frezza
    Corentin Desport
    Carlos Uribe
    Wei Zhao
    Anna Celler
    Philippe Després
    Jean-Mathieu Beauregard
    EJNMMI Physics, 7
  • [8] Comprehensive SPECT/CT system characterization and calibration for 177Lu quantitative SPECT (QSPECT) with dead-time correction
    Frezza, Andrea
    Desport, Corentin
    Uribe, Carlos
    Zhao, Wei
    Celler, Anna
    Despres, Philippe
    Beauregard, Jean-Mathieu
    EJNMMI PHYSICS, 2020, 7 (01)
  • [9] Accuracy and reproducibility of simplified QSPECT dosimetry for personalized 177Lu-octreotate PRRT
    Michela Del Prete
    Frédéric Arsenault
    Nassim Saighi
    Wei Zhao
    François-Alexandre Buteau
    Anna Celler
    Jean-Mathieu Beauregard
    EJNMMI Physics, 5
  • [10] Accuracy and reproducibility of simplified QSPECT dosimetry for personalized 177Lu-octreotate PRRT
    Del Prete, M.
    Arsenault, F.
    Saighi, N.
    Zhao, W.
    Buteau, F. A.
    Celler, A.
    Beauregard, J. M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2018, 45 : S31 - S31