Investigating Occupant Behaviour to Inform Terminal Devices' Control in Mixed-Mode Ventilation Buildings

被引:0
|
作者
Liu, Weihao [1 ]
Gunay, H. Burak [1 ]
Ouf, Mohamed [2 ]
机构
[1] Carleton Univ, Dept Civil & Environm Engn, Ottawa, ON, Canada
[2] Concordia Univ, Dept Bldg Civil & Environm Engn, Montreal, PQ, Canada
来源
关键词
OFFICE BUILDINGS;
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
Operable windows have become desirable design features of modern mechanically ventilated office buildings in North America. While they improve perceived control and adaptive comfort, their inappropriate use poses risks associated with increased heating and cooling energy use. Therefore, the sequence of operations for terminal devices serving zones with operable windows should be designed in recognition of these risks, which in turn should be informed by research investigating occupants' window and thermostat use behaviour. To this end, this paper examines window and thermostat use data collected from two mixed-mode ventilation buildings in Ottawa, Canada. By developing discrete-time Markov logistic regression models that predict the likelihood of thermostat keypress and window opening/closing instances, indoor conditions that trigger these actions are identified. In addition, machine learning approaches such as decision trees are explored to better understand indoor climatic conditions associated with adaptive behaviours. Based on this analysis, a set of preliminary recommendations is developed to improve terminal device sequencing in mixed-mode ventilation buildings in cold climates such that comfort and energy savings potential of operable windows can be fully realized.
引用
收藏
页码:443 / 451
页数:9
相关论文
共 50 条
  • [21] Energy Signatures of Mixed-Mode Cooling and Ventilation
    Lee, Jeongseo
    Kowalchuk, Elizabeth
    Kim, Hyojin
    ASHRAE TRANSACTIONS 2023, VOL 129, PT 1, 2023, 129 : 651 - 660
  • [22] The potential for office buildings with mixed-mode ventilation and low energy cooling systems in arid climates
    Ezzeldin, Sherif
    Rees, Simon J.
    ENERGY AND BUILDINGS, 2013, 65 : 368 - 381
  • [23] The potential of mixed-mode ventilation in office buildings in mild temperate climates: An energy benchmarking analysis
    Veloso, A. C. O.
    Filho, C. R. A.
    Souza, R. V. G.
    ENERGY AND BUILDINGS, 2023, 297
  • [24] Application of Mixed-Mode Ventilation to Enhance Indoor Air Quality and Energy Efficiency in School Buildings
    Otoo, Christopher
    Lu, Tao
    Lü, Xiaoshu
    Energies, 2024, 17 (23)
  • [25] Influence of building design and control parameters on the potential of mixed-mode buildings in India
    Gokarakonda, Sriraj
    van Treeck, Christoph
    Rawal, Rajan
    BUILDING AND ENVIRONMENT, 2019, 148 : 157 - 172
  • [26] Naturally ventilated and mixed-mode buildings-Part II: Optimal control
    Spindler, Henry C.
    Norford, Leslie K.
    BUILDING AND ENVIRONMENT, 2009, 44 (04) : 750 - 761
  • [27] Impact of climate change on energy saving potentials of natural ventilation and ceiling fans in mixed-mode buildings
    Bamdad, Keivan
    Matour, Soha
    Izadyar, Nima
    Omrani, Sara
    Building and Environment, 2022, 209
  • [28] Stochastic control optimization for a mixed mode building considering occupant window opening behaviour
    Tanner, Ryan A.
    Henze, Gregor P.
    JOURNAL OF BUILDING PERFORMANCE SIMULATION, 2014, 7 (06) : 427 - 444
  • [29] Comfort standards and variations in exceedance for mixed-mode buildings
    Borgeson, Sam
    Brager, Gail
    BUILDING RESEARCH AND INFORMATION, 2011, 39 (02): : 118 - 133
  • [30] Impact of climate change on energy saving potentials of natural ventilation and ceiling fans in mixed-mode buildings
    Bamdad, Keivan
    Matour, Soha
    Izadyar, Nima
    Omrani, Sara
    BUILDING AND ENVIRONMENT, 2022, 209