Development of a three-layer phoswich alpha-beta-gamma imaging detector

被引:17
|
作者
Yamamoto, Seiichi [1 ]
Ishibashi, Hiroyuki [2 ]
机构
[1] Nagoya Univ, Radiol & Med Lab Sci, Grad Sch Med, Nagoya, Aichi 4648601, Japan
[2] Hitachi Chem, Ibaraki, Japan
基金
日本科学技术振兴机构;
关键词
Alpha particle; Beta particle; Gamma photons; Imaging detector; Phoswich; Simultaneously; SMALL ANIMAL PET; GSO SCINTILLATORS; SYSTEM; PERFORMANCE; BETA(GAMMA)-RAYS; ACCIDENT; NEUTRONS; ZNS(AG); NE102A; TIME;
D O I
10.1016/j.nima.2015.02.062
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
For radiation monitoring at the sires of such nuclear power plant accidents as Fukushima Daiichi, radiation detectors are needed not only for gamma photons but also for alpha and beta particles because some nuclear fission products emit beta particles and gamma photons and some nuclear fuels contain plutonium that emits alpha particles. In some applications, imaging detectors are required to detect the distribution of plutonium particles that emit alpha particles and radiocesium in foods that emits beta particles and gamma photons. To solve these requirements, we developed an imaging detector that can measure the distribution of alpha and beta particles as well as gamma photons. The imaging detector consists of three-layer scintillators optically coupled to each other and to a position sensitive photomultiplier tube (PSPMT). The first layer, which is made of a thin plastic scintillator (decay Lime: similar to 5 ns), detects alpha particles. The second layer, which is made of a thin Gd2SiO5 (GSO) scintillator with 1.5 mol% Ce (decay time 35 ns), detects beta particles. The third layer made of a thin GSO scintillator with 0.4 mol% Ce (decay time: 70 no) defects gamma photons. Using pulse shape discrimination, the images of these layers can be separated. The position information is calculated by the Anger principle from 8 x 8 anode signals from the PSPMT. The images for the alpha and beta particles and the gamma photons are individually formed by the pulse shape discriminations for each layer. We detected alpha particle images in the first layer and beta particle images in the second layer. Gamma photon images were detected in the second and third layers. The spatial resolution for the alpha and beta particles was similar to 1.25 mm FWHM and less than 2 mm FWHM for the gamma photons. We conclude that our developed alpha-beta-gamma imaging detector is promising for imaging applications not only for the environmental monitoring of radionuclides but also for medical and molecular imaging. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:129 / 134
页数:6
相关论文
共 50 条
  • [31] A DERIVATION OF AN ANALYTIC-EXPRESSION FOR THE TRACKING INDEX FOR THE ALPHA-BETA-GAMMA FILTER
    GRAY, JE
    MURRAY, W
    IEEE TRANSACTIONS ON AEROSPACE AND ELECTRONIC SYSTEMS, 1993, 29 (03) : 1064 - 1065
  • [32] BP-neural Network Alpha-beta-gamma Filter Optimized by GA
    Han, Zhenyu
    Li, Shurong
    ICIEA: 2009 4TH IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS, VOLS 1-6, 2009, : 1943 - 1947
  • [33] Three-layer GSO depth-of-interaction detector for high-energy gamma camera
    Yamamoto, S.
    Watabe, H.
    Kawachi, N.
    Fujimaki, S.
    Kato, K.
    Hatazawa, J.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 743 : 124 - 129
  • [34] REAL-TIME ALPHA-BETA-GAMMA ENVIRONMENTAL RADIATION MONITORING-SYSTEM
    BATTIST, L
    KEENE, W
    SCHADT, W
    THIESS, P
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1977, 27 (NOV): : 133 - 135
  • [35] Development of a low background alpha-beta/gamma coincidence detector
    Baccolo, G.
    Barresi, A.
    Beretta, M.
    Chiesa, D.
    Nastasi, M.
    Previtali, E.
    Sisti, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2021, 1003
  • [36] Phoswich detectors for simultaneous counting of alpha-, beta(gamma)-rays and neutrons
    Usuda, S
    Sakurai, S
    Yasuda, K
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 388 (1-2): : 193 - 198
  • [37] A phoswich alpha/beta detector for monitoring in the site of Fukushima Daiichi Nuclear Power Station
    Morishita, Yuki
    Takasaki, Koji
    Kitayama, Yoshiharu
    Tagawa, Akihiro
    Shibata, Takuya
    Hoshi, Katsuya
    Kaneko, Junichi H.
    Higuchi, Mikio
    Oura, Masatoshi
    RADIATION MEASUREMENTS, 2023, 160
  • [38] Simulation study of a simultaneous beta-gamma-ray detection using a 3-layer phoswich detector and Monte Carlo methods
    Rahimi, M. H.
    Feghhi, S. A. H.
    Khorsandi, M.
    Jafari, H.
    APPLIED RADIATION AND ISOTOPES, 2023, 192
  • [39] Feasibility Assessment of a Phoswich Detector for Simultaneous Measurement of a Mixture of Beta- and Gamma-emitters
    Joo, Hanyoung
    Kim, Jae Wook
    Moon, Joo Hyun
    2018 PROGRESS IN ELECTROMAGNETICS RESEARCH SYMPOSIUM (PIERS-TOYAMA), 2018, : 1172 - 1176
  • [40] The alpha-beta-Gamma tracking filter with a noisy jerk as the maneuver model: Frequency domain solution
    Arcasoy, CC
    IEEE TRANSACTIONS ON AEROSPACE AND ELECTRONIC SYSTEMS, 1996, 32 (03) : 1170 - 1174