Development of a three-layer phoswich alpha-beta-gamma imaging detector

被引:17
|
作者
Yamamoto, Seiichi [1 ]
Ishibashi, Hiroyuki [2 ]
机构
[1] Nagoya Univ, Radiol & Med Lab Sci, Grad Sch Med, Nagoya, Aichi 4648601, Japan
[2] Hitachi Chem, Ibaraki, Japan
基金
日本科学技术振兴机构;
关键词
Alpha particle; Beta particle; Gamma photons; Imaging detector; Phoswich; Simultaneously; SMALL ANIMAL PET; GSO SCINTILLATORS; SYSTEM; PERFORMANCE; BETA(GAMMA)-RAYS; ACCIDENT; NEUTRONS; ZNS(AG); NE102A; TIME;
D O I
10.1016/j.nima.2015.02.062
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
For radiation monitoring at the sires of such nuclear power plant accidents as Fukushima Daiichi, radiation detectors are needed not only for gamma photons but also for alpha and beta particles because some nuclear fission products emit beta particles and gamma photons and some nuclear fuels contain plutonium that emits alpha particles. In some applications, imaging detectors are required to detect the distribution of plutonium particles that emit alpha particles and radiocesium in foods that emits beta particles and gamma photons. To solve these requirements, we developed an imaging detector that can measure the distribution of alpha and beta particles as well as gamma photons. The imaging detector consists of three-layer scintillators optically coupled to each other and to a position sensitive photomultiplier tube (PSPMT). The first layer, which is made of a thin plastic scintillator (decay Lime: similar to 5 ns), detects alpha particles. The second layer, which is made of a thin Gd2SiO5 (GSO) scintillator with 1.5 mol% Ce (decay time 35 ns), detects beta particles. The third layer made of a thin GSO scintillator with 0.4 mol% Ce (decay time: 70 no) defects gamma photons. Using pulse shape discrimination, the images of these layers can be separated. The position information is calculated by the Anger principle from 8 x 8 anode signals from the PSPMT. The images for the alpha and beta particles and the gamma photons are individually formed by the pulse shape discriminations for each layer. We detected alpha particle images in the first layer and beta particle images in the second layer. Gamma photon images were detected in the second and third layers. The spatial resolution for the alpha and beta particles was similar to 1.25 mm FWHM and less than 2 mm FWHM for the gamma photons. We conclude that our developed alpha-beta-gamma imaging detector is promising for imaging applications not only for the environmental monitoring of radionuclides but also for medical and molecular imaging. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:129 / 134
页数:6
相关论文
共 50 条
  • [1] Modeling and optimization of scintillating crystal layers for designing a three-layer phoswich Alpha-Beta-Gamma detector
    Jozani, H. Hashemi
    Khorsandi, M.
    Jafari, H.
    RADIATION PHYSICS AND CHEMISTRY, 2024, 215
  • [2] A miniature phoswich detector for gamma-ray localization and beta imaging
    Tornai, MP
    Levin, CS
    MacDonald, LR
    Holdsworth, CH
    Hoffman, EJ
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (03) : 1166 - 1173
  • [3] Miniature phoswich detector for gamma-ray localization and beta imaging
    UCLA Sch of Medicine, Los Angeles, United States
    IEEE Trans Nucl Sci, 3 pt 2 (1166-1173):
  • [4] A miniature phoswich detector for gamma-ray localization and beta imaging
    Tornai, MP
    Levin, CS
    MacDonald, LR
    Holdsworth, CH
    Hoffman, EJ
    1997 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1 & 2, 1998, : 1028 - 1032
  • [5] A phoswich detector for simultaneous alpha gamma spectroscopy
    Moghadam, S. Rajabi
    Feghhi, S. A. H.
    Safari, M. J.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 799 : 59 - 63
  • [6] The BGO alpha-beta-gamma scintillation spectrometer
    Kalish, Y
    IRPA9 - 1996 INTERNATIONAL CONGRESS ON RADIATION PROTECTION / NINTH INTERNATIONAL CONGRESS OF THE INTERNATIONAL RADIATION PROTECTION ASSOCIATION, PROCEEDINGS, VOL 2, 1996, : B561 - B563
  • [7] A novel phoswich imaging detector for simultaneous beta and coincidence-gamma imaging of plant leaves
    Wu, Heyu
    Tai, Yuan-Chuan
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (17): : 5583 - 5598
  • [8] Optimization Through Simulation for the Triple Layer Phoswich Simultaneous Beta Gamma Detector Upgrade
    Aguayo, Estanislao
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 512 - 515
  • [9] RUTHERFORD ON ALPHA-BETA-GAMMA CLASSIFICATION OF RADIOACTIVE RAYS
    TRENN, TJ
    ISIS, 1976, 67 (236) : 61 - 75
  • [10] Development of a phoswich imaging detector to simultaneously acquire neutron and gamma photon images
    Yamamoto, Seiichi
    Yoshino, Masao
    Nakanishi, Kohei
    Kamada, Kei
    Yoshikawa, Akira
    Tanaka, Hiroki
    Kataoka, Jun
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2024, 1065