Amperometric determination of L-malic acid in a flow injection analysis manifold using packed-bed enzyme reactors

被引:20
|
作者
Prodromidis, MI
TzouwaraKarayanni, SM
Karayannis, MI
Vadgama, P
Maines, A
机构
[1] UNIV IOANNINA,DEPT CHEM,ANALYT CHEM LAB,GR-45110 IOANNINA,GREECE
[2] UNIV MANCHESTER,HOPE HOSP,DEPT MED,SALFORD M6 8HD,LANCS,ENGLAND
关键词
amperometric malate determination; malate dehydrogenase and diaphorase reactors; flow injection analysis; fruits and vegetables;
D O I
10.1039/an9962100435
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An enzymic method for the determination of L-malic acid in fruits and vegetables is described, Malate dehydrogenase (MDH) and diaphorase (DI) were co-immobilized on aminopropyl-, isothiocyanate- and N-hydroxysuccinimide ester (N-HSE)-modified controlled-pore glass, which was then used for the construction of a packed-bed reactor, MDH catalyses the reaction between malate and NAD(+) and produces NADH, which converts hexacyanoferrate(III) into hexacyanoferrate(II) in the presence of the DI, Amperometric measurements with pure graphite electrodes in a fully automated flow injection manifold were used to monitor the concentration of hexacyanoferrate(II) at +0.3 V versus an Ag/AgCl reference electrode, The electrochemical behaviour of hexacyanoferrate(III), 2,6-dichlorophenolindophenol and p-benzoquinone was tested with cyclic voltammetry. Parameters such as working and immobilization pH, flow rate, sample size, temperature and NAD(+) and hexacyanoferrate(III) concentrations were investigated, The interference of various ions, amino acids and organic acids present in real samples was also studied, The calibration graph was linear for the range 2 x 10(-5)-4 x 10(-4) mol l(-1) malate, The reactors remained active for a period of more than 3 months under specified storage conditions, The maximum sample throughput was 30 h(-1) and the relative standard deviation of the method was better than 1.5% (n = 5), The mean relative error was 4% for fruits-and 2% for vegetables, The accuracy of the proposed method was tested by comparison of the results with those obtained by a reference method. Good correlation was attained, Recovery experiments showed results between 95 and 108%.
引用
收藏
页码:435 / 439
页数:5
相关论文
共 50 条
  • [41] MEASUREMENT AND CALCULATION OF THE CALIBRATION GRAPHS FOR FLOW-INJECTION ANALYSIS USING ENZYME REACTORS WITH IMMOBILIZED DEHYDROGENASES AND AN AMPEROMETRIC NADH DETECTOR
    HUCK, H
    SCHELTERGRAF, A
    SCHMIDT, HL
    [J]. BIOELECTROCHEMISTRY AND BIOENERGETICS, 1984, 13 (1-3): : 199 - 209
  • [42] FLOW-INJECTION ANALYSIS OF L-LACTATE WITH ENZYME AMPLIFICATION AND AMPEROMETRIC DETECTION
    ASOUZU, MU
    NONIDEZ, WK
    HO, MH
    [J]. ANALYTICAL CHEMISTRY, 1990, 62 (07) : 708 - 712
  • [43] DETERMINATION OF L-GLUTAMATE BY AMPEROMETRIC FLOW-INJECTION ANALYSIS USING IMMOBILIZED GLUTAMATE OXIDASE - MANIFOLD FOR SIMULTANEOUS DETECTION OF COMPONENT SIGNAL AND BLANK SIGNAL
    MATSUMOTO, K
    SAKODA, K
    OSAJIMA, Y
    [J]. ANALYTICA CHIMICA ACTA, 1992, 261 (1-2) : 155 - 159
  • [44] ANALYSIS OF MODELS FOR DICHLORAMINE REMOVAL BY ACTIVATED CARBON IN BATCH AND PACKED-BED REACTORS USING QUASILINEARIZATION AND ORTHOGONAL COLLOCATION METHODS
    KIM, BR
    SCHMITZ, RA
    SNOEYINK, VL
    TAUXE, GW
    [J]. WATER RESEARCH, 1978, 12 (05) : 317 - 326
  • [45] 2-and 3-Stage temperature ramping for the direct synthesis of adipic acid in micro-flow packed-bed reactors
    Shang, Minjing
    Noel, Timothy
    Wang, Qi
    Su, Yuanhai
    Miyabayashi, Keisuke
    Hessel, Volker
    Hasebe, Shinji
    [J]. CHEMICAL ENGINEERING JOURNAL, 2015, 260 : 454 - 462
  • [46] AMPEROMETRIC DETERMINATION OF GALACTOSE, LACTOSE AND DIHYDROXYACETONE USING GALACTOSE-OXIDASE IN A FLOW-INJECTION SYSTEM WITH IMMOBILIZED ENZYME REACTORS AND ONLINE DIALYSIS
    LUNDBACK, H
    OLSSON, B
    [J]. ANALYTICAL LETTERS PART B-CLINICAL AND BIOCHEMICAL ANALYSIS, 1985, 18 (07): : 871 - 889
  • [47] FLOW-INJECTION ANALYSIS WITH AN ENZYME REACTOR BED FOR DETERMINATION OF ASCORBIC-ACID IN BRAIN-TISSUE
    BRADBERRY, CW
    ADAMS, RN
    [J]. ANALYTICAL CHEMISTRY, 1983, 55 (14) : 2439 - 2440
  • [48] AMPEROMETRIC BIOSENSORS FOR GLUCOSE AND ETHANOL DETERMINATION IN WINE USING FLOW INJECTION ANALYSIS
    Muresan, Laura
    Zor, Kinga Judith
    Nistor, Mihaela
    Csoregi, Elisabeth
    Popescu, Ionel Catalin
    [J]. STUDIA UNIVERSITATIS BABES-BOLYAI CHEMIA, 2008, 53 (01): : 71 - 79
  • [49] Voltammetric Determination of Tumor Biomarkers using Flow Injection Analysis with Amperometric Detection
    Makrlikova, Anna
    Matysik, Frank-Michael
    Navratil, Tomas.
    Barek, Jiri
    Vyskocil, Vlastimil
    [J]. PROCEEDINGS OF THE 13TH INTERNATIONAL STUDENTS CONFERENCE MODERN ANALYTICAL CHEMISTRY, 2017, : 7 - 11
  • [50] AMPEROMETRIC FLOW-INJECTION ANALYSIS OF L-GLUTAMATE USING AN IMMOBILIZED ENZYME REACTOR - AMPLIFICATION BY SUBSTRATE RECYCLING
    YAO, T
    KOBAYASHI, N
    WASA, T
    [J]. ELECTROANALYSIS, 1990, 2 (07) : 563 - 566