Amperometric determination of L-malic acid in a flow injection analysis manifold using packed-bed enzyme reactors

被引:20
|
作者
Prodromidis, MI
TzouwaraKarayanni, SM
Karayannis, MI
Vadgama, P
Maines, A
机构
[1] UNIV IOANNINA,DEPT CHEM,ANALYT CHEM LAB,GR-45110 IOANNINA,GREECE
[2] UNIV MANCHESTER,HOPE HOSP,DEPT MED,SALFORD M6 8HD,LANCS,ENGLAND
关键词
amperometric malate determination; malate dehydrogenase and diaphorase reactors; flow injection analysis; fruits and vegetables;
D O I
10.1039/an9962100435
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An enzymic method for the determination of L-malic acid in fruits and vegetables is described, Malate dehydrogenase (MDH) and diaphorase (DI) were co-immobilized on aminopropyl-, isothiocyanate- and N-hydroxysuccinimide ester (N-HSE)-modified controlled-pore glass, which was then used for the construction of a packed-bed reactor, MDH catalyses the reaction between malate and NAD(+) and produces NADH, which converts hexacyanoferrate(III) into hexacyanoferrate(II) in the presence of the DI, Amperometric measurements with pure graphite electrodes in a fully automated flow injection manifold were used to monitor the concentration of hexacyanoferrate(II) at +0.3 V versus an Ag/AgCl reference electrode, The electrochemical behaviour of hexacyanoferrate(III), 2,6-dichlorophenolindophenol and p-benzoquinone was tested with cyclic voltammetry. Parameters such as working and immobilization pH, flow rate, sample size, temperature and NAD(+) and hexacyanoferrate(III) concentrations were investigated, The interference of various ions, amino acids and organic acids present in real samples was also studied, The calibration graph was linear for the range 2 x 10(-5)-4 x 10(-4) mol l(-1) malate, The reactors remained active for a period of more than 3 months under specified storage conditions, The maximum sample throughput was 30 h(-1) and the relative standard deviation of the method was better than 1.5% (n = 5), The mean relative error was 4% for fruits-and 2% for vegetables, The accuracy of the proposed method was tested by comparison of the results with those obtained by a reference method. Good correlation was attained, Recovery experiments showed results between 95 and 108%.
引用
收藏
页码:435 / 439
页数:5
相关论文
共 50 条
  • [1] SPECTROPHOTOMETRIC DETERMINATION OF L-MALIC ACID WITH A MALIC ENZYME
    SUYE, S
    YOSHIHARA, N
    INUTA, S
    [J]. BIOSCIENCE BIOTECHNOLOGY AND BIOCHEMISTRY, 1992, 56 (09) : 1488 - 1489
  • [2] PACKED-BED ENZYME REACTORS AND ONLINE DIALYZERS IN FLOW-ANALYSIS FOR THE DETERMINATION OF CARBOHYDRATES
    OLSSON, B
    LUNDBACK, H
    JOHANSSON, G
    [J]. ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1987, 501 : 548 - 549
  • [3] OPTIMIZATION OF PEROXIDASE IMMOBILIZATION AND OF THE DESIGN OF PACKED-BED ENZYME REACTORS FOR FLOW-INJECTION ANALYSIS
    OLSSON, B
    OGREN, L
    [J]. ANALYTICA CHIMICA ACTA, 1983, 145 (JAN) : 87 - 99
  • [4] FLOW-INJECTION DETERMINATIONS OF CREATINE AND CREATININE USING PACKED-BED ENZYME REACTORS UNDER EQUILIBRIUM CONDITIONS
    MOGES, G
    JOHANSSON, G
    [J]. ANALYTICAL LETTERS, 1994, 27 (03) : 495 - 510
  • [5] Automatic bionalyzer using an integrated amperometric biosensor for the determination of L-malic acid in wines
    Vargas, E.
    Ruiz, M. A.
    Ferrero, F. J.
    Campuzano, S.
    Ruiz-Valdepenas Montiel, V.
    Reviejo, A. J.
    Pingarron, J. M.
    [J]. TALANTA, 2016, 158 : 6 - 13
  • [6] Determination of malic acid in real samples by using enzyme immobilized reactors and amperometric detection
    Manzoli, A
    Tomita, LSN
    Fertonani, FL
    de Oliveira-Neto, G
    Mascini, M
    Yamanaka, H
    [J]. ANALYTICAL LETTERS, 2004, 37 (09) : 1823 - 1832
  • [7] Comparison of flow injection analytical biosystems based on open-tube and packed-bed enzyme reactors
    Jurkiewicz, M
    Alegret, S
    Fàbregas, E
    [J]. ANALYTICA CHIMICA ACTA, 1998, 370 (01) : 47 - 58
  • [8] AN ANALYSIS OF RADIAL FLOW PACKED-BED REACTORS - HOW ARE THEY DIFFERENT
    CHANG, HC
    CALO, JM
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1980, 180 (AUG): : 54 - INDE
  • [9] Development of an Amperometric Biosensor Platform for the Combined Determination of l-Malic, Fumaric, and l-Aspartic Acid
    Roehlen, Desiree L.
    Pilas, Johanna
    Schoening, Michael J.
    Selmer, Thorsten
    [J]. APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 2017, 183 (02) : 566 - 581
  • [10] Development of an Amperometric Biosensor Platform for the Combined Determination of l-Malic, Fumaric, and l-Aspartic Acid
    Désirée L. Röhlen
    Johanna Pilas
    Michael J. Schöning
    Thorsten Selmer
    [J]. Applied Biochemistry and Biotechnology, 2017, 183 : 566 - 581