Normal values of exhaled carbon monoxide in healthy subjects: comparison between two methods of assessment

被引:19
|
作者
Moscato, Umberto [1 ]
Poscia, Andrea [1 ]
Gargaruti, Riccardo [2 ]
Capelli, Giovanni [3 ]
Cavaliere, Franco [2 ]
机构
[1] Univ Cattolica Sacro Cuore, Hyg Div, Inst Publ Hlth, I-00168 Rome, Italy
[2] Univ Cattolica Sacro Cuore, Inst Anaesthesia & Intens Care, I-00168 Rome, Italy
[3] Univ Cassino, Inst Hyg, I-03043 Cassino, Italy
来源
BMC PULMONARY MEDICINE | 2014年 / 14卷
关键词
Carbon monoxide; Exhaled carbon monoxide; Photo-acoustic spectrometer; Electrochemical analyser; AIR; BIOMARKERS; ABSTINENCE; CHILDREN; MARKER;
D O I
10.1186/1471-2466-14-204
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Background: In a previous study, exhaled carbon monoxide (eCO) has been assessed in healthy non-smokers with a photo acoustic spectrometer Bruel&Kjaer 1312. Unexpectedly, values were higher than those reported in literature, which were mostly obtained with electrochemical analysers. This study was aimed to compare eCO values obtained with Bruel&Kjaer 1312 and PiCO + Smokerlyzer, a largely utilized electrochemical analyser. Methods: Thirty-four healthy subjects, 15 non- smokers and 19 smokers, underwent eCO assessment with Bruel&Kjaer1312 and PiCO + Smokerlyzer during a prolonged expiration (15 seconds). Bruel&Kjaer 1312 assessed CO concentration 7 and 12 seconds after the beginning of expiration and displayed the mean value. PiCO + Smokerlyzer was utilized according to the manufacturer's recommendations. In vitro, the two devices were tested with standard concentrations of CO in nitrogen (5, 9.9, 20, and 50 ppm), and the time needed by PiCO + Smokerlyzer readings to stabilize was assessed at different gas flows. Results: Both Bruel&Kjaer 1312 and PiCO + Smokerlyzer presented very good internal consistency. The values provided were strictly correlated, but at low test concentrations, the Bruel&Kjaer 1312 readings were greater than the PiCO + Smokerlyzer, and vice versa. PiCO + Smokerlyzer overestimated the CO standard concentrations at 5 and 9.9 ppm by 20%, while Bruel&Kjaer 1312 measures were correct. PiCO + Smokerlyzer readings stabilized in 12 seconds during in vitro tests and in 15 seconds during in vivo measurements, suggesting that the values displayed corresponded to the initial phase of expiration. Conclusions: Differences between Bruel&Kjaer 1312 and PiCO + Smokerlyzer may be explained because Bruel&Kjaer 1312 measured CO levels in the middle and at the end of expiration while PiCO + Smokerlyzer assessed them in the initial part of expiration.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Comparison of Two Methods to Measure Macular Pigment Optical Density in Healthy Subjects
    Creuzot-Garcher, Catherine
    Koehrer, Philippe
    Picot, Caroline
    Aho, Serge
    Bron, Alain M.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (05) : 2941 - 2946
  • [22] Relationship between exhaled carbon monoxide and airway hyperresponsiveness in asthmatic patients
    Ramirez, M
    García-Río, F
    Viñas, A
    Prados, C
    Pino, JM
    Villamor, J
    JOURNAL OF ASTHMA, 2004, 41 (01) : 109 - 116
  • [23] NORMAL VALUES OF SPIROMETRY AND CARBON-MONOXIDE TRANSPORT IN CHILD
    HOMASSON, JP
    ROULLIER, A
    BOISSINOT, E
    BULLETIN DE PHYSIO-PATHOLOGIE RESPIRATOIRE, 1975, 11 (03): : P177 - P178
  • [24] RELATIONSHIP BETWEEN ENDOGENOUS CARBON MONOXIDE PRODUCTION AND TOTAL HEME MASS IN NORMAL AND ABNORMAL SUBJECTS
    COLTMAN, CA
    DUDLEY, GM
    AMERICAN JOURNAL OF THE MEDICAL SCIENCES, 1969, 258 (06): : 374 - &
  • [25] Relation between exhaled carbon monoxide levels and clinical severity of asthma
    Yamaya, M
    Hosoda, M
    Ishizuka, S
    Monma, M
    Matsui, T
    Suzuki, T
    Sekizawa, K
    Sasaki, H
    CLINICAL AND EXPERIMENTAL ALLERGY, 2001, 31 (03): : 417 - 422
  • [26] Association between exhaled carbon monoxide and asthma outcomes in Peruvian children
    Pereira, Amanda A.
    Pollard, Suzanne L.
    Locke, Robert
    Romero, Karina
    Lima, John J.
    Hansel, Nadia N.
    Checkley, William
    RESPIRATORY MEDICINE, 2018, 145 : 212 - 216
  • [27] The,effect of age,and gender on exhaled nitric oxide (NO) and carbon monoxide (CO) in healthy individuals
    Duncan, JM
    Pyle, J
    Taber, M
    Laskowski, D
    Dweik, RA
    CHEST, 2003, 124 (04) : 164S - 165S
  • [28] Endogenous carbon monoxide and cardiometabolic risk: can measuring exhaled carbon monoxide be used to refine cardiometabolic risk assessment?
    Nayor, Matthew
    Vasan, Ramachandran S.
    FUTURE CARDIOLOGY, 2015, 11 (01) : 9 - 12
  • [29] Assessment of the incretin effect in healthy subjects: concordance between clamp and OGTT methods
    Aulinger, Benedikt A.
    D'Alessio, David A.
    AMERICAN JOURNAL OF PHYSIOLOGY-ENDOCRINOLOGY AND METABOLISM, 2023, 325 (04): : E412 - E420
  • [30] Comparison of two methods for exhaled breath condensate collection
    Soyer, O. U.
    Dizdar, E. A.
    Keskin, O.
    Lilly, C.
    Kalayci, O.
    ALLERGY, 2006, 61 (08) : 1016 - 1018