Conditions for Textile Electrode Sensors to Monitor Cardiac Activity in Daily Life

被引:4
|
作者
Kim, Jae Kwan [1 ,2 ]
Park, Sangin [1 ]
Cho, Hyun-Seung [3 ]
Yang, Jin-Hee [3 ]
Lee, Soo-Hong [2 ]
Lee, Jeong-Whan [4 ]
机构
[1] Korea Inst Sci & Technol, Bion Res Ctr, Seoul 02792, South Korea
[2] Yonsei Univ, Sch Mech Engn, Seoul 03722, South Korea
[3] Yonsei Univ, Inst Symbiot Life TECH, Seoul 03722, South Korea
[4] Konkuk Univ, Dept Biomed Engn, Chungju 27478, South Korea
关键词
Textile electrode sensor; Cardiac activity; Wearable platform; Smart healthcare; SYSTEM; HEART;
D O I
10.1007/s42835-022-01156-6
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This study determined the conditions for textile electrode sensors combined with a garment-type wearable platform to monitor daily cardiac activity. Six types of textile sensors were implemented by manipulating the size and configuration of textile electrodes. Each sensor was attached to a chest band to fabricate experimental garments, which were sequentially worn by ten healthy males. Their electrocardiogram (ECG) signals were measured using the modified Lead II method. We sampled ECG signals at 1 kHz using a Biopac ECG100 device. The signal power ratio of the ECG signals acquired from each electrode was calculated, and statistical analysis was performed. The results indicate that convex electrodes detect higher quality signals than flat electrodes. However, no significant difference was observed in the performance of cardiac activity acquisition in terms of electrode size. These results validate that the type of configuration, namely flat or convex, significantly impacts the performance of cardiac activity signal acquisition. Additionally, correlation coefficients, mean error, and Bland-Altman plots revealed a strong positive correlation, low mean error, and adequate agreement, respectively, between ECG and all textile sensors. The study's findings form the basis for implementing a wearable platform that integrates textile sensors with garments.
引用
收藏
页码:3045 / 3055
页数:11
相关论文
共 50 条
  • [31] Physiological approach to monitor patients in congestive heart failure: application of a new implantable device-based system to monitor daily life activity and ventilation
    Page, Eric
    Cazeau, Serge
    Ritter, Philippe
    Galley, Daniel
    Casset, Cyrille
    EUROPACE, 2007, 9 (08): : 687 - 693
  • [32] The stroke upper-limb activity monitor: Its sensitivity to measure hemiplegic upper-limb activity during daily life
    de Niet, Mark
    Bussmann, Johannes B.
    Ribbers, Gerard M.
    Stam, Henk J.
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2007, 88 (09): : 1121 - 1126
  • [33] The recursive model as a new approach to validate and monitor activity sensors
    Guillaume Body
    Robert B. Weladji
    Øystein Holand
    Behavioral Ecology and Sociobiology, 2012, 66 : 1531 - 1541
  • [34] The recursive model as a new approach to validate and monitor activity sensors
    Body, Guillaume
    Weladji, Robert B.
    Holand, Oystein
    BEHAVIORAL ECOLOGY AND SOCIOBIOLOGY, 2012, 66 (11) : 1531 - 1541
  • [36] Increase daily activity for a longer life
    不详
    GERIATRIC NURSING, 2006, 27 (05) : 261 - 261
  • [37] Material conditions and daily life in the Ancient Regime
    Novo Zaballos, Jose Rufino
    CHRONICA NOVA, 2016, (42): : 477 - 479
  • [38] VARIATIONS IN ELECTROCARDIOGRAM UNDER CONDITIONS OF DAILY LIFE
    HINKLE, LE
    CARVER, S
    BENJAMIN, B
    COOPER, H
    MCLEMORE, G
    WINSTON, L
    SHEPHERD, EN
    STRONE, BW
    CHRISTENSON, WN
    CIRCULATION, 1963, 28 (04) : 736 - &
  • [39] Implantable Device to Monitor Cardiac Activity with Sternal Wires
    Ganapathy, Anand
    Palmer, Aaron
    Burrer, Angie
    Bersi, Matthew
    Garza, Javier
    Razavi, Mehdi
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2014, 37 (12): : 1630 - 1640
  • [40] Techniques for various sensors improve industry aptitudes, daily life
    Anon
    JEE. Journal of electronic engineering, 1993, 30 (321): : 93 - 97