Dual-source CT coronary imaging in heart transplant recipients:: image quality and optimal reconstruction interval

被引:18
|
作者
Bastarrika, Gorka [1 ]
De Cecco, Carlo N. [2 ]
Arraiza, Maria [1 ]
Ubilla, Matias [3 ]
Mastrobuoni, Stefano [3 ]
Pueyo, Jesus C. [1 ]
Rabago, Gregorio [3 ]
机构
[1] Univ Navarra, Clin Univ, Dept Radiol, Pamplona 31008, Spain
[2] Univ Roma La Sapienza, Osped St Andrea, Dept Radiol, I-00189 Rome, Italy
[3] Univ Navarra, Clin Univ, Dept Cardiovasc Surg, Pamplona 31008, Spain
关键词
coronary vessels; heart; dual Source CT; image quality; reconstruction interval; heart transplantation;
D O I
10.1007/s00330-008-0957-2
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The image quality and optimal reconstruction interval for coronary arteries in heart transplant recipients undergoing non-invasive dual-source computed tomography (DSCT) coronary angiography was evaluated. Twenty consecutive heart transplant recipients who underwent DSCT coronary angiography were included (19 male, one female; mean age 63.1+/-10.7 years). Data sets were reconstructed in 5% steps from 30% to 80% of the R-R interval. Two blinded independent observers assessed the image quality of each coronary segments using a five-point scale (from 0=not evaluative to 4=excellent quality). A total of 289 coronary segments in 20 heart transplant recipients were evaluated. Mean heart rate during the scan was 89.1+/-10.4 bpm. At the best reconstruction interval, diagnostic image quality (score >= 2) was obtained in 93.4% of the coronary segments (270/289) with a mean image quality score of 3.04+/-0.63. Systolic reconstruction intervals provided better image quality scores than diastolic reconstruction intervals (overall mean quality scores obtained with the systolic and diastolic reconstructions 3.03+/-1.06 and 2.73+/-1.11, respectively; P < 0.001). Different systolic reconstruction intervals (35%, 40%, 45% of RR interval) did not yield to significant differences in image quality scores for the coronary segments (P=0.74). Reconstructions obtained at the systolic phase of the cardiac cycle allowed excellent diagnostic image quality coronary angiograms in heart transplant recipients undergoing DSCT coronary angiography.
引用
收藏
页码:1791 / 1799
页数:9
相关论文
共 50 条
  • [41] Dual-Source CT in Congenital Heart Disease
    Ruehm, S.
    Lohan, D.
    Krishnam, M.
    Panknin, C.
    Lell, M. M.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (05)
  • [42] Dynamic imaging with dual-source gated Computed Tomography (CT): Implications of motion parameters on image quality for wrist imaging
    Neo, Puay Yong
    Jais, Ita Suzana Mat
    Panknin, Christoph
    Lau, Chin Cheung
    Chan, Lai Peng
    An, Kai Nan
    Tay, Shian Chao
    MEDICAL ENGINEERING & PHYSICS, 2013, 35 (12) : 1837 - 1842
  • [43] Image reconstruction and image quality evaluation for a dual source CT scanner
    Flohr, T. G.
    Bruder, H.
    Stierstorfer, K.
    Petersilka, M.
    Schmidt, B.
    McCollough, C. H.
    MEDICAL PHYSICS, 2008, 35 (12) : 5882 - 5897
  • [44] In vivo radiation dosimetry and image quality of turbo-flash and retrospective dual-source CT coronary angiography
    Schicchi, Nicolo
    Mari, Alberto
    Fogante, Marco
    Esposto Pirani, Paolo
    Agliata, Giacomo
    Tosi, Niccolo
    Palumbo, Pierpaolo
    Cannizzaro, Ester
    Bruno, Federico
    Splendiani, Alessandra
    Di Cesare, Ernesto
    Maggi, Stefania
    Giovagnoni, Andrea
    RADIOLOGIA MEDICA, 2020, 125 (02): : 117 - 127
  • [45] Does Clinical Pretest Probability Influence Image Quality and Diagnostic Accuracy in Dual-Source Coronary CT Angiography?
    Thomas, Christoph
    Brodoefel, Harald
    Tsiflikas, Ilias
    Bruckner, Friederike
    Reimann, Anja
    Ketelsen, Dominik
    Drosch, Tanja
    Claussen, Claus D.
    Kopp, Andreas
    Heuschmid, Martin
    Burgstahler, Christof
    ACADEMIC RADIOLOGY, 2010, 17 (02) : 212 - 218
  • [46] Dual-source spiral CT with pitch up to 3.2 and 75 ms temporal resolution: Image reconstruction and assessment of image quality
    Flohr, Thomas G.
    Leng, Shuai
    Yu, Lifeng
    Allmendinger, Thomas
    Bruder, Herbert
    Petersilka, Martin
    Eusemann, Christian D.
    Stierstorfer, Karl
    Schmidt, Bernhard
    McCollough, Cynthia H.
    MEDICAL PHYSICS, 2009, 36 (12) : 5641 - 5653
  • [47] In vivo radiation dosimetry and image quality of turbo-flash and retrospective dual-source CT coronary angiography
    Nicolò Schicchi
    Alberto Mari
    Marco Fogante
    Paolo Esposto Pirani
    Giacomo Agliata
    Niccolò Tosi
    Pierpaolo Palumbo
    Ester Cannizzaro
    Federico Bruno
    Alessandra Splendiani
    Ernesto Di Cesare
    Stefania Maggi
    Andrea Giovagnoni
    La radiologia medica, 2020, 125 : 117 - 127
  • [48] Evaluation of the Optimal Image Reconstruction Interval for Coronary Artery Imaging Using 64-slice CT
    Weininger, M.
    Ritter, C.
    Beer, M.
    Hahn, D.
    Beissert, M.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (05)
  • [49] Effectiveness Best R-R Reconstruction Interval Determination Software for the Evaluation of Dual-Source Coronary CT Angiography Examinations
    Erol, Bekir
    Karcaaltincaba, Musturay
    Cay, Nurdan
    Hazirolan, Tuncay
    Aytemir, Kudret
    Akata, Deniz
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2011, 35 (02) : 229 - 234
  • [50] Quantification of left ventricular function and mass in heart transplant recipients using dual-source CT and MRI:: initial clinical experience
    Bastarrika, Gorka
    Arraiza, Maria
    De Cecco, Carlo N.
    Mastrobuoni, Stefano
    Ubilla, Matias
    Rabago, Gregorio
    EUROPEAN RADIOLOGY, 2008, 18 (09) : 1784 - 1790