A numerical study on the scale-up behaviour in oscillatory baffled columns

被引:44
|
作者
Jian, H [1 ]
Ni, X [1 ]
机构
[1] Heriot Watt Univ, Sch Engn & Phys Sci, COBRA, Edinburgh EH14 4AS, Midlothian, Scotland
来源
CHEMICAL ENGINEERING RESEARCH & DESIGN | 2005年 / 83卷 / A10期
基金
英国工程与自然科学研究理事会;
关键词
scale-up; oscillatory baffled column; CFD modelling; flow patterns; velocity ratio;
D O I
10.1205/cherd.03312
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
In this paper, we report our numerical study into the scale-up behaviour of batch oscillatory baffled columns (OBC). The numerical work is carried out for single phase flow only using an unsteady 3-D laminar solver from FLUENT 5, and flow patterns in three batch OBCs of 50, 100 and 200 rum in diameter have been simulated. Surface and cycle averaged velocity and velocity ratios are analysed, and the study shows that the scale-up of OBCs can be treated as linear, since the velocity ratios in the OBCs are largely independent of the column diameter. The results are in line with the experimental studies reported previously.
引用
收藏
页码:1163 / 1170
页数:8
相关论文
共 50 条
  • [21] Scale-up correlation for mass transfer coefficients in pulsed baffled reactors
    Ni, X
    Gao, S
    CHEMICAL ENGINEERING JOURNAL, 1996, 63 (03): : 157 - 166
  • [22] Oxygen mass transfer and scale-up studies in baffled roller bioreactors
    Nikakhtari, H.
    Song, W.
    Nemati, M.
    Hill, G. A.
    BIOPROCESS AND BIOSYSTEMS ENGINEERING, 2014, 37 (02) : 193 - 203
  • [23] Oxygen mass transfer and scale-up studies in baffled roller bioreactors
    H. Nikakhtari
    W. Song
    M. Nemati
    G. A. Hill
    Bioprocess and Biosystems Engineering, 2014, 37 : 193 - 203
  • [24] Numerical scale-up study for orthokinetic agglomeration in stirred vessels
    Hollander, ED
    Derksen, JJ
    Portela, LM
    Van den Akker, HEA
    AICHE JOURNAL, 2001, 47 (11) : 2425 - 2440
  • [25] Scale-up of reactive distillation columns with catalytic packings
    Hoffmann, A
    Noeres, C
    Górak, A
    CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2004, 43 (03) : 383 - 395
  • [26] CONTRIBUTION TO DESIGN AND SCALE-UP OF PACKED-COLUMNS
    BILLET, R
    FETT WISSENSCHAFT TECHNOLOGIE-FAT SCIENCE TECHNOLOGY, 1990, 92 (09): : 361 - 370
  • [27] CONTRIBUTION TO PACKED COLUMNS SCALE-UP IN SEPARATION PROCESSES
    Reinhard Billet
    Chinese Journal of Chemical Engineering, 1992, (02) : 235 - 252
  • [28] Scale-Up Study on the Performance of Annular Pulsed Disc-and-Doughnut Columns
    Liu, Jian-Quan
    Li, Shao-Wei
    Jing, Shan
    SOLVENT EXTRACTION AND ION EXCHANGE, 2016, 34 (05) : 485 - 501
  • [29] A systematic study of the effect of geometrical parameters on mixing time in oscillatory baffled columns
    Dept. of Mech. and Chem. Engineering, Heriot-Watt University, Riccarton, Edinburgh EH14 4AS, United Kingdom
    不详
    不详
    Chem. Eng. Res. Des., A5 (635-642):
  • [30] A systematic study of the effect of geometrical parameters on mixing time in oscillatory baffled columns
    Ni, X
    Brogan, G
    Struthers, A
    Bennett, DC
    Wilson, SF
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 1998, 76 (A5): : 635 - 642