Real-time, high-throughput measurements of peptide-MHC-I dissociation using a scintillation proximity assay

被引:54
|
作者
Harndahl, Mikkel [1 ]
Rasmussen, Michael [1 ]
Roder, Gustav [1 ]
Buus, Soren [1 ]
机构
[1] Univ Copenhagen, Expt Immunol Lab, Fac Hlth Sci, DK-2200 Copenhagen N, Denmark
关键词
MHC-I; Peptide; Stability; Dissociation; Scintillation proximity assay; SURFACE-PLASMON RESONANCE; FLUORESCENCE POLARIZATION; IMMUNOGENIC PEPTIDES; MOLECULES; BINDING; STABILITY; HLA-A-ASTERISK-0201; DEPENDS;
D O I
10.1016/j.jim.2010.10.012
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Efficient presentation of peptide-MHC class I complexes to immune T cells depends upon stable peptide-MHC class I interactions. Theoretically, determining the rate of dissociation of a peptide-MHC class I complexes is straightforward; in practical terms, however, generating the accurate and closely timed data needed to determine the rate of dissociation is not simple. Ideally, one should use a homogenous assay involving an inexhaustible and label-free assay principle. Here, we present a homogenous, high-throughput peptide-MHC class I dissociation assay, which by and large fulfill these ideal requirements. To avoid labeling of the highly variable peptide, we labeled the invariant beta 2m and monitored its dissociation by a scintillation proximity assay, which has no separation steps and allows for real-time quantitative measurement of dissociation. Validating this work-around to create a virtually label-free assay, we showed that rates of peptide-MHC class I dissociation measured in this assay correlated well with rates of dissociation rates measured conventionally with labeled peptides. This assay can be used to measure the stability of any peptide-MHC class I combination, it is reproducible and it is well suited for high-throughput screening. To exemplify this, we screened a panel of 384 high-affinity peptides binding to the MHC class I molecule, HLA-A*02:01, and observed the rates of dissociation that ranged from 0.1 h to 46 h depending on the peptide used. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:5 / 12
页数:8
相关论文
共 50 条
  • [41] Novel estrogen receptor ligands and their structure-activity relationship evaluated by scintillation proximity assay for high-throughput screening
    He, L
    Xiang, H
    Zhang, LY
    Tian, WS
    He, HH
    DRUG DEVELOPMENT RESEARCH, 2005, 64 (04) : 203 - 212
  • [42] A high-throughput screening system for α1-3 fucosyltransferase-VII inhibitor utilizing scintillation proximity assay
    Miyashiro, M
    Furuya, S
    Sugita, T
    ANALYTICAL BIOCHEMISTRY, 2005, 338 (01) : 168 - 170
  • [43] A high-throughput competitive scintillation proximity aminoacyl-tRNA synthetase charging assay to measure amino acid concentration
    Forbes, Chris D.
    Myung, Jayhyuk
    Landro, James A.
    ANALYTICAL BIOCHEMISTRY, 2007, 363 (02) : 246 - 254
  • [44] Development of a high-throughput real-time bioluminescence-monitoring system
    Okamoto, Kazuhisa
    Onai, Kiyoshi
    Ishiura, Masahiro
    PLANT AND CELL PHYSIOLOGY, 2007, 48 : S1 - S1
  • [45] Development of a high-throughput scintillation proximity assay for the identification of C-domain translational initiation factor 2 inhibitors
    Delle Fratte, S
    Piubelli, C
    Domenici, E
    JOURNAL OF BIOMOLECULAR SCREENING, 2002, 7 (06) : 541 - 546
  • [47] Improved real-time RT-PCR method for high-throughput measurements using second derivative calculation and double correction
    Luu-The, V
    Paquet, N
    Calvo, E
    Cumps, J
    BIOTECHNIQUES, 2005, 38 (02) : 287 - 293
  • [48] Optimization of a real-time high-throughput assay for assessment of Streptococcus mutans metabolism and screening of antibacterial dental adhesives
    Florez, Fernando Luis Esteban
    Hiers, Rochelle Denise
    Zhao, Yan
    Merritt, Justin
    Rondinone, Adam Justin
    Khajotia, Sharukh Soli
    DENTAL MATERIALS, 2020, 36 (03) : 353 - 365
  • [49] A high-throughput microfluidic biochip to quantify bacterial adhesion to single host cells by real-time PCR assay
    Zhang, Rui
    Gong, Hai-Qing
    Zeng, Xu Dong
    Sze, Chun Chau
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (12) : 4277 - 4282
  • [50] A high-throughput microfluidic biochip to quantify bacterial adhesion to single host cells by real-time PCR assay
    Rui Zhang
    Hai-Qing Gong
    Xu Dong Zeng
    Chun Chau Sze
    Analytical and Bioanalytical Chemistry, 2013, 405 : 4277 - 4282