EXPERIMENTAL INVESTIGATION OF SEAWATER FOULING EFFECT ON THE 90/10 Cu/Ni TUBE

被引:0
|
作者
Izadi, M. [1 ]
Aidun, D. K. [1 ]
Marzocca, P. [1 ]
Lee, H.
机构
[1] Clarkson Univ, Dept Mech & Aeronaut Engn, Potsdam, NY 13699 USA
来源
ASME POWER CONFERENCE, 2010 | 2010年
关键词
ELECTROCHEMICAL CORROSION; HEAT; COPPER;
D O I
10.1115/POWER2010-27155
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The fouling effect of seawater on a 90/10 Cu/Ni commercial heat exchanger tube is investigated. A fouling monitoring device, designed on the basis of fouling thermal resistance, is used for the current experimental study. First, the seawater samples collected in different times from Hampton, Rye, and Wallis beaches in New Hampshire, USA are vacuum-filtered down to a 10 mu m filter paper to remove suspended solids, micro-organisms, and the majority of biological spores. Then, the filtered seawater samples are circulated through the closed loop experimental setup for two weeks and the fouling thermal resistance is measured continuously. The results show different fouling behavior for the seawater samples confirmed by the different composition of the samples. Analytical microscopy is performed on the tube surface before and after the experiments to see the effect of seawater fouling on the tube surface. The results of fouling monitoring experiments reveal a higher fouling thermal resistance for one of the seawater samples, Hampton seawater, contrary to the results of SEM1\EDS2 analysis which show lower crystallization for Hampton sample. Water decomposition analysis shows the lowest sodium content for Hampton seawater compared to the other samples. Accordingly, accelerated corrosion of the tube surface occurs for Hampton seawater due to the presence of chlorine ions and low concentration of sodium. The high fouling resistance of Hampton seawater can be explained by participation of several fouling mechanisms simultaneously which makes a composite fouling behavior for Hampton seawater sample. The results of the current study are critical for the industries which use seawater as the cooling water source.
引用
收藏
页码:171 / 180
页数:10
相关论文
共 50 条
  • [21] Experimental fouling investigation with electroless Ni-P coatings
    Al-Janabi, A.
    Malayeri, M. R.
    Mueller-Steinhagen, H.
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2010, 49 (06) : 1063 - 1071
  • [22] Experimental investigation of the air side fouling of finned tube heat exchangers
    Edelin, Denis
    Bariteau, Nicolas
    Etourneau, Yoann
    Traonvouez, Luc
    Soto, Jerome
    HEAT AND MASS TRANSFER, 2019, 55 (10) : 2713 - 2722
  • [23] Experimental investigation on the composite fouling characteristics of the convergent-divergent tube
    School of Energy Resources and Mechanical Engineering, Northeast Dianli University, Jilin 132012, China
    不详
    Kung Cheng Je Wu Li Hsueh Pao, 2008, 2 (320-322): : 320 - 322
  • [24] Experimental investigation of the air side fouling of finned tube heat exchangers
    Denis Edelin
    Nicolas Bariteau
    Yoann Etourneau
    Luc Traonvouez
    Jérôme Soto
    Heat and Mass Transfer, 2019, 55 : 2713 - 2722
  • [25] 5-(3-Aminophenyl)tetrazole - A new corrosion inhibitor for Cu-Ni (90/10) alloy in seawater and sulphide containing seawater
    Rao, B. V. Appa
    Kumar, K. Chaitanya
    ARABIAN JOURNAL OF CHEMISTRY, 2017, 10 : S2245 - S2259
  • [26] Evolution of the Corrosion Product Film and Its Effect on the Erosion-Corrosion Behavior of Two Commercial 90Cu-10Ni Tubes in Seawater
    Ekerenam, Okpo O.
    Ma, Ai-Li
    Zheng, Yu-Gui
    He, Si-Yu
    Okafor, Peter C.
    ACTA METALLURGICA SINICA-ENGLISH LETTERS, 2018, 31 (11) : 1148 - 1170
  • [27] Evolution of the Corrosion Product Film and Its Effect on the Erosion–Corrosion Behavior of Two Commercial 90Cu–10Ni Tubes in Seawater
    Okpo O.Ekerenam
    Ai-Li Ma
    Yu-Gui Zheng
    Si-Yu He
    Peter C.Okafor
    Acta Metallurgica Sinica(English Letters), 2018, 31 (11) : 1148 - 1170
  • [28] Evolution of the Corrosion Product Film and Its Effect on the Erosion–Corrosion Behavior of Two Commercial 90Cu–10Ni Tubes in Seawater
    Okpo O. Ekerenam
    Ai-Li Ma
    Yu-Gui Zheng
    Si-Yu He
    Peter C. Okafor
    Acta Metallurgica Sinica (English Letters), 2018, 31 : 1148 - 1170
  • [29] Effect of iron as alloying element on electrochemical behaviour of 90: 10 Cu-Ni alloy
    Taher, A. M.
    Jarjoura, G.
    Kipouros, G. J.
    CANADIAN METALLURGICAL QUARTERLY, 2011, 50 (04) : 425 - 438
  • [30] Corrosion investigation of Cu-Ni tube desalination plant
    Abouswa, K.
    Elshawesh, F.
    Elragei, O.
    Elhood, A.
    DESALINATION, 2007, 205 (1-3) : 140 - 146