The Effect of Body Mass Index on Fluoroscopic Time and Radiation Dose During Sacroiliac Joint Injections

被引:18
|
作者
Cushman, Daniel [1 ]
Flis, Alexandra [1 ]
Jensen, Ben [1 ]
McCormick, Zachary [2 ]
机构
[1] Univ Utah, Div Phys Med & Rehabil, 590 Wakara Way, Salt Lake City, UT 84108 USA
[2] Northwestern Univ, Rehabil Inst Chicago, Dept Phys Med & Rehabil, Feinberg Sch Med, Chicago, IL 60611 USA
关键词
EXPOSURE; OBESITY; SPINE; PAIN; OVERWEIGHT; RADIOLOGY; MORTALITY; IMPACT; WOMEN; RISK;
D O I
10.1016/j.pmrj.2015.11.008
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Background: Sacroiliac joint (SIJ) injections are commonly performed under fluoroscopic guidance. Radiation exposure to patients and providers has not been comprehensively studied, particularly the effect of body mass index (BMI). Objective: To identify whether patients with a larger BMI require longer fluoroscopy time or a larger radiation dose during performance of an SIJ injection. Design: Retrospective study of an academic institution database. Setting: Academic outpatient musculoskeletal clinic. Patients: All patients who underwent SIJ injections during a 10-year period. Main Outcome Measurements: Machine-reported fluoroscopic time and machine-reported radiation dose. A Bonferroni correction was implemented with P < .01 as statistically significant. Results: A total of 453 SIJ injections were performed in 359 patients. No statistically significant differences in fluoroscopy time were found between patients with BMI scores identified as normal, overweight, and obese (P = .054). However, the radiation doses were significantly greater for patients with higher BMI scores (chi(2) [2, n = 441] = 62.4, P < .001); the median (interquartile range) doses were 1210 (839), 1671 (1240), and 2090 (2170) mGy-cm(2) for normal weight, overweight, and obese patients, respectively. Although longer needles were used more often in obese patients (chi(2) [2, n = 452] = 31.5, P < .001), fluoroscopy time was not associated with needle length (P = .162). No relationships were identified between fluoroscopy time and first-time (as opposed to repeat) injection (P = .123), trainee involvement (chi(2) [1, n = 698] = 3.9, P = .049), or age (P = .337). Conclusions: Patients with an elevated BMI score who are undergoing SIJ injection receive an increased radiation dose despite equivalent fluoroscopic time. This finding suggests that the increased dose is likely due to x-ray output from the fluoroscope traversing a greater tissue mass, as opposed to the physician requiring more fluoroscopic images for proper needle placement. Fortunately, the increased radiation dose delivered to patients with a larger BMI score likely has negligible effects.
引用
收藏
页码:767 / 772
页数:6
相关论文
共 50 条
  • [21] Effect of Body Habitus on Radiation Dose During CT Fluoroscopy-Guided Spine Injections
    Viola, Ronald J.
    Nguyen, Giao B.
    Yoshizumi, Terry T.
    Stinnett, Sandra S.
    Hoang, Jenny K.
    Kranz, Peter G.
    INTERVENTIONAL NEURORADIOLOGY, 2014, 20 (05) : 525 - 532
  • [22] Fluoroscopic-Guided Lumbar Puncture: Fluoroscopic Time and Implications of Body Mass Index-A Baseline Study
    Boddu, S. R.
    Corey, A.
    Peterson, R.
    Saindane, A. M.
    Hudgins, P. A.
    Chen, Z.
    Wang, X.
    Applegate, K. E.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2014, 35 (08) : 1475 - 1480
  • [23] Fluoroscopic Organ and Tissue-Specific Radiation Exposure by Sex and Body Mass Index During Ureteroscopy Editorial Comment
    Canales, Benjamin K.
    Arreola, Manuel
    JOURNAL OF ENDOUROLOGY, 2010, 24 (07) : 1072 - 1073
  • [24] DETERMINATION OF RADIATION DOSE DURING FLUOROSCOPIC PROCEDURES WITH THE AID OF THE FLUOROSCOPIC SIMULATOR
    MILLER, WB
    ROHRER, RH
    WEENS, HS
    RADIOLOGY, 1962, 78 (02) : 237 - 239
  • [25] Is There a Relationship Between Body Mass Index and Fluoroscopy Time During Cervical Interlaminar Epidural Steroid Injections?
    McCormick, Zachary L.
    Mattie, Ryan
    Ebrahimi, Ali
    Lee, David T.
    Marcolina, Austin
    Press, Joel
    Kennedy, D. J.
    Smuck, Matthew
    Walega, David R.
    Cushman, Daniel
    PAIN MEDICINE, 2017, 18 (07) : 1326 - 1333
  • [26] Effect of body mass index on dose delivery in phototherapy
    Mughal, A.
    Edwards, C.
    Carter, A.
    Thurston, A.
    Partleton, C.
    Wyness, K.
    Coles-Jones, L.
    Gambles, B.
    Lloyd, A.
    Godfrey, J.
    Anstey, A. V.
    BRITISH JOURNAL OF DERMATOLOGY, 2012, 167 : 72 - 72
  • [27] Association Between Corticosteroid Dose and Pain Reduction After Sacroiliac Joint Injections
    Naber, William J.
    Scribner, Darin
    Kalpakjian, Claire Z.
    Bakshi, Rishi
    AMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION, 2025, 104 (02) : 152 - 154
  • [28] Effect of Fluoroscopic-Guided Corticosteroid Injection in Patients With Sacroiliac Joint Dysfunction
    Patel, Anurag
    Kumar, Dileep
    Singh, Shailendra
    Mohan, Ravindra
    Mishra, Sudhir
    Gupta, Anil K.
    Yadav, Ganesh
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (03)
  • [29] Effect of post-pyloric Dobhoff tube retention during gastrojejunostomy for reduction of fluoroscopic time and radiation dose
    Thompson, Tyler S.
    Small, Coulter N.
    Davis, Hugh
    Lazarowicz, Michael
    Vogel, Jeffrey
    Heithaus, Robert E.
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2023, 29 (05): : 710 - 712
  • [30] The impact of body mass index on patient radiation dose in general radiography
    Dolenc, Laura
    Petrinjak, Barbara
    Mekis, Nejc
    Skrk, Damijan
    JOURNAL OF RADIOLOGICAL PROTECTION, 2022, 42 (04)