LONG TERM OPERATION OF COOLING SYSTEM FOR THE KEPCO HTS POWER CABLE

被引:0
|
作者
Yang, H. S. [1 ]
Kim, D. L. [1 ]
Sohn, S. H. [2 ]
Lim, J. H. [2 ]
Choi, Y. S. [1 ]
Hwang, S. D. [2 ]
机构
[1] Korea Basic Sci Inst, Taejon 305333, South Korea
[2] Korea Elect Power Res Inst, Taejon 305380, South Korea
关键词
HTS power cable; cooling system;
D O I
10.1063/1.3422443
中图分类号
O414.1 [热力学];
学科分类号
摘要
HTS power cable systems of to several hundred meters in length are presently being developed and evaluated for practical use in real power grids. Since 2006, a cooling system for the 3-phase, 100-m FITS power cable with 22.9 kV/1.25 kA has been installed and tested at the KEPCO's Gochang power-testing center. Performance reliability through several demonstration tests of over 9,000 hours was demonstrated. This paper mainly describes the cooling performance test results of the HTS power cable system obtained during the long-term performance tests.
引用
收藏
页码:879 / +
页数:2
相关论文
共 50 条
  • [31] Transient analysis of an HTS DC power cable with an HVDC system
    Dinh, Minh-Chau
    Ju, Chang-Hyeon
    Kim, Jin-Geun
    Park, Minwon
    Yu, In-Keun
    Yang, Byeongmo
    [J]. PHYSICA C-SUPERCONDUCTIVITY AND ITS APPLICATIONS, 2013, 494 : 311 - 318
  • [32] Feasibility of inline cooling in long distance HTS power line
    Zajaczkowski, B.
    Giesbers, A. J. M.
    Holtrust, M.
    Haenen, E.
    den Heijer, R.
    [J]. CRYOGENICS, 2011, 51 (04) : 180 - 186
  • [33] Design procedure and operation experience of data acquisition and control system for 22.9 kV underground HTS power cable
    Ryoo, H. S.
    Sohn, S. H.
    Hwang, S. D.
    Lim, J. H.
    Choi, H. S.
    Yatsuka, K.
    Masuda, T.
    Isojima, S.
    Watanabe, M.
    Suzawa, C.
    Koo, J. Y.
    [J]. PHYSICA C-SUPERCONDUCTIVITY AND ITS APPLICATIONS, 2007, 463 (SUPPL.): : 1139 - 1145
  • [34] The three-phase 75 m long HTS power cable
    Dai, S. T.
    Lin, L. Z.
    Lin, Y. B.
    Gao, Z. Y.
    Fang, Y. F.
    Gong, L. H.
    Teng, Y. P.
    Zhang, F. Y.
    Xu, X.
    Li, G.
    Li, L. F.
    Xiao, L. Y.
    [J]. CRYOGENICS, 2007, 47 (7-8) : 402 - 405
  • [35] Demonstration and verification tests of 500 m long HTS power cable
    Takahashi, T
    Suzuki, H
    Ichikawa, M
    Okamoto, T
    Akita, S
    Mukoyama, S
    Ishii, N
    Kimura, A
    Yasuda, K
    [J]. IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2005, 15 (02) : 1823 - 1826
  • [36] Observation of the thermosiphon effect in the circulation of liquid nitrogen in HTS cable cooling system
    Ivanov, Yury
    Watanabe, Hirofumi
    Hamabe, Makoto
    Kawahara, Toshio
    Sun, Jian
    Yamaguchi, Satarou
    [J]. ADVANCES IN SUPERCONDUCTIVITY XXIV, 2012, 27 : 368 - 371
  • [37] Development of FACTS operation technology to the KEPCO power network - Installation & operation
    Choo, JB
    Chang, BH
    Lee, HS
    Shin, HS
    Koh, KK
    [J]. IEEE/PES TRANSMISSION AND DISTRIBUTION CONFERENCE AND EXHIBITION 2002: ASIA PACIFIC, VOLS 1-3, CONFERENCE PROCEEDINGS: NEW WAVE OF T&D TECHNOLOGY FROM ASIA PACIFIC, 2002, : 2008 - 2013
  • [38] Development of KEPCO equivalent systems for the KEPCO enhanced power system simulator
    Jang, G
    Lee, B
    Kwon, SH
    Kim, HJ
    Yoon, YB
    Choo, JB
    [J]. INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2001, 23 (07) : 577 - 583
  • [39] Long-Term Operation and Fault Tests of a 22.9 kV Hybrid SFCL in the KEPCO Test Grid
    Hyun, Ok-Bae
    Yim, Seong-Woo
    Yu, Seung-Duck
    Yang, Seong Eun
    Kim, Woo-Seok
    Kim, Hye-Rim
    Lee, Gyeong-Ho
    Sim, Jungwook
    Park, Kwon-Bae
    [J]. IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2011, 21 (03) : 2131 - 2134
  • [40] The stability evaluation on HTS power cable
    Bae, Joon-Han
    Choi, Suk-Jin
    Lee, Sang-Jin
    Sim, Ki-Deok
    Cho, Jeon-Wook
    Kim, Ho-Min
    [J]. IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2008, 18 (02) : 1289 - 1292