Intra-prosthetic dislocation of dual-mobility cups after total hip arthroplasty: potential causes from a clinical and biomechanical perspective

被引:35
|
作者
Fabry, Christian [1 ]
Langlois, Jean [2 ]
Hamadouche, Moussa [2 ]
Bader, Rainer [1 ]
机构
[1] Univ Med Rostock, Biomech & Implant Technol Res Lab, Dept Orthopaed, Doberaner Str 142, D-18057 Rostock, Germany
[2] Univ Paris 05, Hop Cochin, AP HP, Dept Orthopaed & Reconstruct Surg, 27 Rue Faubourg St Jacques, F-75014 Paris, France
关键词
Total hip arthroplasty; Wear; Dual mobility socket; Implant failure; Bousquet system; IPD; FOLLOW-UP; INTRAPROSTHETIC DISLOCATION; REPLACEMENT; SOCKET; STABILITY; REVISION; MOTION; HEAD; SYSTEM; RANGE;
D O I
10.1007/s00264-015-3000-7
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction Recurrent dislocation of total hip arthroplasty is a frequent indication for revision surgery. Hip joint stability depends on implant design, cup position and crucially on femoral head diameter. Due to an effective ultra-large diameter femoral head, dual-mobility cups are considered an attractive solution to prevent dislocation in unstable conditions. Although patients obviously benefit for many years in terms of mobility and pain, an increase of intra-prosthetic dislocation reports using dual-mobility cups has been recently observed. However, the failure mechanism of this implant-specific complication, which is characterized by the loss of the positive-locking between the femoral head and the mobile liner, is not yet completely understood. Methods A comprehensive search was performed with the PubMed database and a search engine to overview this topic and to identify potential causes for this implant-specific failure from a clinical and biomechanical perspective. Results Peri-operative findings indicate extensive fibrosis at the large articulation as well as cup loosening as potential causes. In addition, current research has shown that the failure mechanism is affected by the surface topography of the femoral neck and in particular by the design of the mobile liner. Discussion In clinical practice it is necessary to differentiate a classic dislocation between the mobile liner and the metallic shell from an intra-prosthetic dislocation between the femoral head and the liner. Conclusion Due to the increasing popularity of dual-mobility cups in total hip arthroplasty, the understanding of which implant-specific features or tissue response may increase the risk of intra-prosthetic dislocation is of major importance for reduced revision rates by using optimized surgical techniques and implant designs.
引用
收藏
页码:901 / 906
页数:6
相关论文
共 50 条
  • [21] Intraprosthetic Dislocation of a Modular Dual-Mobility Total Hip Arthroplasty With Posterior Migration of the Polyethylene Liner
    Cantrell, Austin J.
    Forrester, D. Alex
    Crawford, Alexander W.
    Morris, Cade
    Thakral, Rishi
    ARTHROPLASTY TODAY, 2024, 25
  • [22] Dual Mobility Cups in Revision Total Hip Arthroplasty: Efficient Strategy to Decrease Dislocation Risk
    Schmidt, Axel
    Batailler, Cecile
    Fary, Camdon
    Servien, Elvire
    Lustig, Sebastien
    JOURNAL OF ARTHROPLASTY, 2020, 35 (02): : 500 - 507
  • [23] Cost Analysis of Dual-Mobility Constructs in Revision Total Hip Arthroplasty: A European Payer Perspective
    Abdel, Matthew P.
    Miller, Larry E.
    Hull, Stephen A.
    Coppolecchia, Andrea B.
    Hanssen, Arlen D.
    Pagnano, Mark W.
    ORTHOPEDICS, 2020, 43 (04) : 250 - +
  • [24] A comparative study about the incidence of dislocation and peri-prosthetic fracture between dual mobility versus standard cups after primary total hip arthroplasty
    Sappey-Marinier, Elliot
    Viste, Anthony
    Blangero, Yoann
    Desmarchelier, Romain
    Fessy, Michel-Henri
    INTERNATIONAL ORTHOPAEDICS, 2019, 43 (12) : 2691 - 2695
  • [25] A comparative study about the incidence of dislocation and peri-prosthetic fracture between dual mobility versus standard cups after primary total hip arthroplasty
    Elliot Sappey-Marinier
    Anthony Viste
    Yoann Blangero
    Romain Desmarchelier
    Michel-Henri Fessy
    International Orthopaedics, 2019, 43 : 2691 - 2695
  • [26] Do Dual-Mobility Cups Reduce the Risk of Dislocation in Total Hip Arthroplasty for Fractured Neck of Femur in Patients Aged Older Than 75 Years?
    Nich, Christophe
    Vandenbussche, Eric
    Augereau, Bernard
    Sadaka, Jerome
    JOURNAL OF ARTHROPLASTY, 2016, 31 (06): : 1256 - 1260
  • [27] Dual Mobility Cups Present Promising Outcomes in Primary Total Hip Arthroplasty Patients At A Risk of Dislocation
    Moon, Nam Hoon
    Do, Min Uk
    Kim, Jung Shin
    Seo, Jae Seung
    Shin, Won Chul
    Research Square, 2021,
  • [28] Dual-Mobility Cups in Patients Undergoing Primary Total Hip Arthroplasty with Prior Lumbar Spine Fusion: A Systematic Review
    Issa, Tariq Ziad
    Pearl, Adam
    Moore, Emelia
    Maqsood, Hannan Ahmad
    Saleh, Khaled J.
    SURGERIES, 2024, 5 (02): : 125 - 134
  • [29] Dual-mobility cups in total hip arthroplasty after femoral neck fractures: A retrospective study comparing outcomes between cemented and cementless fixation
    Uriarte, Iker
    Moreta, Jesus
    Jimenez, Inigo
    Legarreta, Maria Jose
    Mozos, Jose Luis Martinez de los
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2021, 52 (06): : 1467 - 1472
  • [30] Study protocol: Effectiveness of dual-mobility cups compared with uni-polar cups for preventing dislocation after primary total hip arthroplasty in elderly patients - design of a randomized controlled trial nested in the Dutch Arthroplasty Registry
    Van Beers, Loes W. A. H.
    van der Wal, Bart C. H.
    Van Loon, Tess Glastra
    Moojen, Dirk Jan F.
    Van Wier, Marieke F.
    Klaassen, Amanda D.
    Willigenburg, Nienke W.
    Poolman, Rudolf W.