The design of an industry-sponsored randomized controlled trial to compare synthetic mesh versus biologic mesh for inguinal hernia repair

被引:11
|
作者
Bellows, C. F. [1 ]
Shadduck, P. P. [2 ,3 ]
Helton, W. S. [4 ]
Fitzgibbons, R. J. [5 ]
机构
[1] Tulane Univ, Hlth Sci Ctr, Dept Surg SL 22, New Orleans, LA 70115 USA
[2] N Carolina Specialty Hosp, Durham, NC USA
[3] Duke Univ, Durham, NC USA
[4] Hosp San Raphael, New Haven, CT USA
[5] Creighton Univ, Omaha, NE 68178 USA
关键词
Inguinal hernia; Randomized clinical trial; Biologic mesh; Activities assessment; Chronic pain; POLYPROPYLENE MESH; CLINICAL-TRIAL; LIGHTWEIGHT;
D O I
10.1007/s10029-010-0773-x
中图分类号
R61 [外科手术学];
学科分类号
摘要
Biologic prostheses are designed to support tissue regeneration rather than just result in a strong scar plate, as is the case with synthetic mesh. It is not known if these newer materials will result in earlier return to normal activities and/or less post-herniorrhaphy groin pain. A prospective, randomized, controlled, third-party-blinded multicenter trial was designed to compare the use of a non-cross linked porcine dermis biologic graft [Strattice(TM) Reconstructive Tissue Matrix (RTM), LifeCell, Branchburg, NJ] versus light weight, large pore polypropylene mesh (UltraPro(TM), Ethicon, Somerville, NJ). The study design called for recruitment of 170 men. These men are being followed for a minimum of 2 years. The primary aim of this study is to compare the safety and effectiveness of the two materials in a Lichtenstein inguinal hernia repair as measured by resumption of activities of daily living. Secondary outcomes include chronic pain, postoperative complications and the incidence of re-herniation at 12 and 24 months. This paper discusses the study design, patient recruitment and the current status of the clinical trial. The study involves nine medical centers, all with extensive experience in hernia repair. After 24 months of enrollment, 172 men were randomized and recruitment was then closed. All patients underwent elective repair of primary unilateral inguinal hernias as an outpatient operation. Follow up data are being collected. Data analyses are scheduled at 3, 12, and 24 months postoperatively. We report the design of a multi-center, third-party blinded, randomized clinical trial comparing a new surgical device with existing technology in the repair of inguinal hernias. We believe this investigator-designed and conducted trial could serve as a model for similar trials examining surgical devices performed in collaboration with industry.
引用
收藏
页码:325 / 332
页数:8
相关论文
共 50 条
  • [31] Randomized clinical trial comparing lightweight or heavyweight mesh for mesh plug repair of primary inguinal hernia
    T. Hirose
    Y. Takayama
    S. Komatsu
    Y. Shingu
    E. Sakamoto
    S. Norimizu
    H. Hasegawa
    Hernia, 2014, 18 : 213 - 219
  • [32] Biologic versus synthetic mesh in open ventral hernia repair: A systematic review and meta-analysis of randomized controlled trials
    de Figueiredo, Sergio Mazzola Poli
    Tastaldi, Luciano
    Mao, Rui-Min Diana
    Lima, Diego Laurentino
    Huang, Li -Ching
    Lu, Richard
    SURGERY, 2023, 173 (04) : 1001 - 1007
  • [33] Randomized clinical trial comparing lightweight or heavyweight mesh for mesh plug repair of primary inguinal hernia
    Hirose, T.
    Takayama, Y.
    Komatsu, S.
    Shingu, Y.
    Sakamoto, E.
    Norimizu, S.
    Hasegawa, H.
    HERNIA, 2014, 18 (02) : 213 - 219
  • [34] Tension-free inguinal hernia repair: TEP versus mesh-plug versus lichtenstein - A prospective randomized controlled trial
    Bringman, S
    Ramel, S
    Heikkinen, TJ
    Englund, T
    Westman, B
    Anderberg, B
    ANNALS OF SURGERY, 2003, 237 (01) : 142 - 147
  • [35] Laparoscopic Repair of Very Large Hiatus Hernia With Sutures Versus Absorbable Mesh Versus Nonabsorbable Mesh A Randomized Controlled Trial
    Watson, David I.
    Thompson, Sarah K.
    Devitt, Peter G.
    Smith, Lorelle
    Woods, Simon D.
    Aly, Ahmad
    Gan, Susan
    Game, Philip A.
    Jamieson, Glyn G.
    ANNALS OF SURGERY, 2015, 261 (02) : 282 - 289
  • [36] Laparoscopic Versus Open Mesh Repair for Inguinal Hernia
    Fujita, Tetsuji
    ANNALS OF SURGERY, 2009, 250 (02) : 353 - 354
  • [37] Laparoscopic versus open mesh repair of inguinal hernia
    Wellwood, J
    Sculpher, M
    Stoker, D
    BRITISH MEDICAL JOURNAL, 1999, 318 (7192): : 1214 - 1214
  • [38] Randomized clinical trial of lightweight composite mesh for Lichtenstein inguinal hernia repair
    Post, S
    Weiss, B
    Willer, M
    Neufang, T
    Lorenz, D
    BRITISH JOURNAL OF SURGERY, 2004, 91 (01) : 44 - 48
  • [39] Randomized and Comparative Clinical Trial of Bovine Mesh Versus Polypropylene Mesh in the Repair of Inguinal Hernias
    Sun, Li
    Chen, Jie
    Li, Juan
    Shen, Yingmo
    SURGICAL LAPAROSCOPY ENDOSCOPY & PERCUTANEOUS TECHNIQUES, 2020, 30 (01): : 26 - 29
  • [40] Fully extraperitoneal laparoscopic inguinal hernia repair using conventional mesh versus tailor-made mosquito mesh: a randomized controlled trial from Cameroon
    Essola, B.
    Himpens, J.
    Limgba, A.
    Landenne, J.
    Tamchom, D. D.
    Ngaroua, E.
    Lingier, P.
    Mboudou, E. T.
    Souopgui, J.
    Hermans, M. P.
    Loi, P.
    BRITISH JOURNAL OF SURGERY, 2021, 108 (09) : E294 - E295