Induction of hypocalcaemia and evaluation of reticuloruminal motility using a three-axis accelerometer

被引:0
|
作者
Choi, Woojae [1 ]
Ro, Younghye [1 ]
Kim, Dohee [1 ]
Hong, Leegon [1 ]
Kim, Danil [1 ,2 ]
机构
[1] Seoul Natl Univ, Coll Vet Med, Dept Farm Anim Med, Seoul 08826, South Korea
[2] Seoul Natl Univ, Inst Green Bio Sci & Technol, Farm Anim Clin Training & Res Ctr, Pyeongchang 25354, South Korea
基金
芬兰科学院;
关键词
dairy cows; detection of periparturient disease; calcium; forestomach motility in cattle; induced hypocalcaemia; remote sensing; smart farming; three-axis accelerometer; SUBCLINICAL HYPOCALCEMIA; METABOLIC PREDICTORS; EDTA INFUSION; CALCIUM; MAGNESIUM; BLOOD; RUMINATION; PHOSPHATE; RISK; COWS;
D O I
10.1071/AN21532
中图分类号
S8 [畜牧、 动物医学、狩猎、蚕、蜂];
学科分类号
0905 ;
摘要
Context Reticuloruminal motility, which is continuous and regular, is essential for digestive activity, but some functional abnormalities can appear in cattle with several metabolic disorders. Particularly in periparturient dairy cows, decreased blood calcium concentrations induce deterioration of rumen motility as well as the risk of reproductive disorders. Aims This study aimed to evaluate reticuloruminal motility using a bolus-type biosensor incorporated with a three-axis accelerometer (3XA) following induction of hypocalcaemia by infusion of ethylenediamine-tetraacetic acid disodium salt dihydrate (Na(2)EDTA) solution. Methods In the 2 x 2 crossover experiment, six non-pregnant and non-lactating cows were assigned to each of the treatment (TRE) and control (CON) groups and infused for 1 h with 13% Na(2)EDTA solution and physiological saline respectively. The cylindrical biosensor was fed and placed in the reticulum before the experiment, and the three acceleration values of each cow were recorded and transmitted wirelessly. Considering the device shape, the reticuloruminal motility was represented as the vector value (V-2) calculated with each change in X- and Z-axis acceleration over time. Key results Plasma calcium concentrations were measured to confirm hypocalcaemia, and the average was significantly decreased to 1.23 mmol/L at 1 h in TRE. The mean V-2 value was significantly decreased in TRE compared with CON, from 1 to 2 h after Na(2)EDTA infusion. Conclusion 3XA was able to detect a change in reticuloruminal motility caused by hypocalcaemia. The use of 3XA in cattle will allow for rapid treatment of hypocalcaemia or other metabolic disorders that reduce productivity. Implications The 3XA inserted into the reticulum of a dairy cow detected a decrease in reticuloruminal motility wirelessly caused by induced hypocalcaemia.
引用
收藏
页码:409 / 415
页数:7
相关论文
共 50 条
  • [31] Integrated chip of capacitive three-axis accelerometer and sensing circuit
    Lan, Jian-Cheng
    Hsueh, Ya-Hsin
    Hung, Chung
    ELECTRONICS LETTERS, 2015, 51 (20) : 1576 - 1577
  • [32] HIGH-G SURVIVABLE MEMS THREE-AXIS ACCELEROMETER
    Hader, Grzegorz
    Smyth, Jefferey
    PROCEEDINGS OF ASME 2023 INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, IMECE2023, VOL 12, 2023,
  • [33] A monolithic three-axis SOI-accelerometer with uniform sensitivity
    Röjegård, H
    Johansson, C
    Enoksson, P
    Andersson, G
    SENSORS AND ACTUATORS A-PHYSICAL, 2005, 123-24 : 50 - 53
  • [34] A 2μW three-axis MEMS-based accelerometer
    Denison, Timothy
    Consoer, Kelly
    Santa, Wesley
    Hutt, Mike
    Miesel, Keith
    2007 IEEE INSTRUMENTATION & MEASUREMENT TECHNOLOGY CONFERENCE, VOLS 1-5, 2007, : 721 - +
  • [35] Computationally Efficient Calibration Algorithm for Three-Axis Accelerometer and Magnetometer
    Papafotis, Konstantinos
    Sotiriadis, Paul P.
    2019 8TH INTERNATIONAL CONFERENCE ON MODERN CIRCUITS AND SYSTEMS TECHNOLOGIES (MOCAST), 2019,
  • [36] A Method to Compensate Packaging Effects on Three-axis MEMS Accelerometer
    Chang, Chia-Cheng
    Yang, Hung-Te
    Su, Yen-Fu
    Hong, Yu-Ting
    Chiang, Kuo-Ning
    2016 15TH IEEE INTERSOCIETY CONFERENCE ON THERMAL AND THERMOMECHANICAL PHENOMENA IN ELECTRONIC SYSTEMS (ITHERM), 2016, : 536 - 538
  • [37] Research on Packaging Effects of Three-axis SOI MEMS Accelerometer
    Yang, Hung-Te
    Su, Yen-Fu
    Chiang, Kuo-Ning
    2015 16TH INTERNATIONAL CONFERENCE ON THERMAL, MECHANICAL AND MULTI-PHYSICS SIMULATION AND EXPERIMENTS IN MICROELECTRONICS AND MICROSYSTEMS (EUROSIME), 2015,
  • [38] Micromachined three-axis thermal accelerometer with a single composite heater
    Bahari, Jamal
    Leung, Albert M.
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2011, 21 (07)
  • [39] Structure mechanics analysis of three-axis piezoresistive micro accelerometer
    Shi, Yun-bo
    Meng, Mei-yu
    Ma, Zong-min
    ISTM/2007: 7TH INTERNATIONAL SYMPOSIUM ON TEST AND MEASUREMENT, VOLS 1-7, CONFERENCE PROCEEDINGS, 2007, : 5052 - 5055
  • [40] Fabrication of a Three-Axis Capacitive MEMS Accelerometer on a Single Substrate
    Aydemir, Akin
    Akin, Tayfun
    2015 IEEE SENSORS, 2015, : 528 - 531