An improved HPLC-MS/MS method for simultaneous quantification of propranolol and its two phase I metabolites in plasma of infants with hemangioma and its application to a comparative study of plasma concentrations

被引:6
|
作者
He, Huan [1 ]
Li, Li [2 ]
Zhao, Libo [1 ]
Sun, Ning [1 ]
Zhang, Meng [1 ]
Cheng, Ying [2 ]
Yu, Lu [2 ]
Ma, Lin [2 ]
Wang, Xiaoling [1 ]
机构
[1] Capital Med Univ, Beijing Childrens Hosp, Clin Res Ctr, Natl Ctr Childrens Hlth, Beijing 100045, Peoples R China
[2] Capital Med Univ, Beijing Childrens Hosp, Dept Dermatol, Natl Ctr Childrens Hlth, Beijing 100045, Peoples R China
来源
RSC ADVANCES | 2018年 / 8卷 / 65期
关键词
BASIC METABOLITES; MECHANISMS; EXTRACTION; ASSAY;
D O I
10.1039/c8ra06252h
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Propranolol is now a preferred treatment for infantile hemangioma. However, there are no published papers on the metabolism and concentrations of propranolol in the plasma of infants with hemangioma. In the present study, a sensitive, simple and reliable method was developed and validated for the simultaneous quantification of propranolol and its metabolites 4-hydroxypropranolol (M1) and Ndesisopropylpropranolol (M2) in infants' plasma for the first time by using liquid chromatography-tandem mass spectrometry (LC-MS/MS). A volume of 100 mu L plasma was prepared by one-step protein precipitation with acetonitrile (300 mL), followed by its separation on an Hypersil GOLD C-18 column maintained at 40 degrees C with gradient mobile phase consisting of 0.1% formic acid aqueous solution and acetonitrile at a flow rate of 0.3 mL min(-1). The quantification was performed via multiple reaction monitoring (MRM) by a triple quadrupole mass spectrometer under positive electrospray ionization (ESI) mode. Bisoprolol was chosen as the internal standard. The method was validated to demonstrate its selectivity, linearity, accuracy, precision, recovery, matrix effect and stability. The matrix-matched calibration curves for propranolol ranging from 1 to 500 ng mL(-1), for M1 ranging from 0.2 to 100 ng mL(-1) and for M2 ranging from 0.2 to 100 ng mL(-1) were all linear, with correlation coefficients calculated using weighted (1/x(2)) least square linear regression analysis. The lower limits of quantification (LLOQs) were 1 ng mL(-1), 0.2 ng mL(-1) and 0.2 ng mL(-1) for propranolol, M1 and M2, respectively. The intra-day and inter-day precisions were less than 7.1% and relative errors were all less than 9.8%. This validated method was successfully applied to quantify the concentrations of propranolol and its metabolites 4-hydroxypropranolol (M1) and N- desisopropylpropranolol (M2) in the plasma of infants with hemangioma after oral administration of different doses of propranolol for the first time.
引用
收藏
页码:37286 / 37294
页数:9
相关论文
共 50 条
  • [21] Determination of panduratin A in rat plasma by HPLC-MS/MS and its application to a pharmacokinetic study
    Kim, Minsoo
    Choi, Seungmok
    Noh, Keumhan
    Kim, Changhee
    Kim, Eunyoung
    Hwang, Jae-Kwan
    Kang, Wonku
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2017, 137 : 151 - 154
  • [22] Simultaneous quantification of volitinib and gefitinib in rat plasma by HPLC-MS/MS for application to a pharmacokinetic study in rats
    Noh, Chi-Kyoung
    Lee, Jong-Hwa
    Kim, Min-Soo
    Maeng, Han-Joo
    Chung, Suk-Jae
    JOURNAL OF SEPARATION SCIENCE, 2017, 40 (19) : 3782 - 3791
  • [23] Simultaneous determination of Pyragrel, a novel anti-thrombotic agent, and its two primary metabolites in plasma by HPLC-MS/MS
    Yang, Guoping
    Pei, Qi
    Fu, Chengxiao
    Huang, Jie
    Chen, Jun
    Yang, Shuang
    Xiang, Yuxia
    Wang, Jing
    Tan, Hongyi
    Liu, Xiaolei
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2018, 156 : 199 - 205
  • [24] Validation of an LC-MS/MS method for simultaneous quantification of venlafaxine and its five metabolites in rat plasma and its application in a pharmacokinetic study
    Gu, Guodong
    Black, Michelle
    Cookson, Colt
    Fiorella, Anna
    Li, Yinghe
    Gorman, Steven H.
    Bakhtiar, Ray
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2018, 1087 : 29 - 35
  • [25] Development of a simple and rapid HPLC-MS/MS method for quantification of streptomycin in mice and its application to plasma pharmacokinetic studies
    Wang, Zhijun
    Xie, Chen
    Yeung, Steven
    Wang, Jeffrey
    Chow, Moses S. S.
    BIOMEDICAL CHROMATOGRAPHY, 2019, 33 (02)
  • [26] Simultaneous quantification of donafenib, sorafenib, and their N-oxide metabolites in rat plasma using a HPLC-MS/MS method
    Lou, Yutao
    Sun, Zhiyong
    Chai, Yitao
    Qin, Hui
    Hu, Qing
    Liu, Yujia
    Zheng, Xiaowei
    Hu, Ying
    Bao, Meihua
    Gu, Jinping
    Zhang, Yiwen
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2023, 1229
  • [27] An HPLC-MS method for simultaneous estimation of α,β-arteether and its metabolite dihydroartemisinin, in rat plasma for application to pharmacokinetic study
    Rajanikanth, M
    Madhusudanan, KP
    Gupta, RC
    BIOMEDICAL CHROMATOGRAPHY, 2003, 17 (07) : 440 - 446
  • [28] Simultaneous Determination of Six Components in Beagle Plasma by HPLC-MS/MS and its Application in Pharmacokinetic Studies
    Zhu, Yongliang
    Li, Shuanglong
    Fang, Jiaao
    Wang, Xiangdie
    Jin, Junli
    Chen, Lingyun
    Qiu, Xiangjun
    BASIC & CLINICAL PHARMACOLOGY & TOXICOLOGY, 2020, 126 : 132 - 132
  • [29] HPLC-MS/MS method for troventol determination in human plasma and its application to biological samples
    Nikitina, Aleksandra
    Grigoriev, Alexander
    Sidorova, Alla
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2017, 143 : 237 - 240
  • [30] Simultaneous Quantification of Four Compounds in Rat Plasma by HPLC-MS/MS and Its Application to Pharmacokinetic Study after Oral Administration of Pomegranate Flowers
    Yisimayili, Zainaipuguli
    Tian, Qiang
    Xie, Yang
    Hu, Pei
    Abdulla, Rahima
    Wu, Tao
    Sun, Zhaolin
    Chen, Mingcang
    Aisa, Haji Akber
    Huang, Chenggang