A Device to Detect Hyperbilirubin through Non-Invasive Technique

被引:1
|
作者
Deepthi, A. Renu [1 ]
Singh, Chanchal [1 ]
Jeeva, J. B. [1 ]
机构
[1] VIT Univ, Sch Elect Engn, Dept Sensor & Biomed Technol, Vellore, Tamil Nadu, India
关键词
Hyperbilirubinemia; Non-Invasive; Bilirubin; LED; Photodiode; BILIRUBIN;
D O I
10.1109/i-pact44901.2019.8960054
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
Hyperbilirubinemia is due to rise in the amount of bilirubin concentration in the body. A technique that can easily detect Jaundice through non-invasive method is presented. The bilirubin detection system begins with the projection of blue light (450-500nm) from LED on the skin in dark surrounding. The reflected light from the skin is measured by photodiode and the data obtained is sent to the microcontroller. The voltage values of the reflected light are proportional to the concentration of the bilirubin. This data is further processed by microcontroller and the level of the bilirubin (severity of Jaundice) is displayed on LCD. This method can be implemented for early and instant detection of Jaundice in Neonates as well as in adults without any physical pain.
引用
收藏
页数:4
相关论文
共 50 条
  • [41] NON-INVASIVE IMAGING BIOMARKERS TO DETECT NASH IN SUBJECTS WITH NAFLD
    Vessby, Johan
    Hockings, Paul
    Gummesson, Anders
    Johansson, Edvin
    Heurling, Kerstin
    Lowenmark, Anna Froden
    Eriksson, Olof
    Johansson, Lars
    Roberts, Caleb
    Hedstrom, Anders
    Schultheis, Christian
    Schoelch, Corinna
    Niessen, Heiko
    Hulthe, Johannes
    Lubberink, Mark
    Ahlstrom, Hakan
    Rorsman, Fredrik
    Wanders, Alkwin
    HEPATOLOGY, 2020, 72 : 931A - 932A
  • [42] A non-invasive device to objectively measure tibial rotation: verification of the device
    Lorbach, Olaf
    Wilmes, P.
    Maas, S.
    Zerbe, T.
    Busch, L.
    Kohn, D.
    Seil, R.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2009, 17 (07) : 756 - 762
  • [43] A non-invasive device to objectively measure tibial rotation: verification of the device
    Olaf Lorbach
    P. Wilmes
    S. Maas
    T. Zerbe
    L. Busch
    D. Kohn
    R. Seil
    Knee Surgery, Sports Traumatology, Arthroscopy, 2009, 17 : 756 - 762
  • [44] A Novel Non-Invasive Screening Device for Aortic Stenosis
    Harb, Serge C.
    Kassab, Joseph
    Collier, Patrick H.
    Grimm, Richard A.
    Ramchand, Jay
    Kapadia, Samir R.
    CIRCULATION, 2023, 148
  • [45] Method and device for non-invasive blood glucose measurement
    Amerov, AK
    Jeon, KJ
    Kim, YJ
    Yoon, G
    OPTICAL DIAGNOSTICS OF BIOLOGICAL FLUIDS IV, PROCEEDINGS OF, 1999, 3599 : 33 - 42
  • [47] A Portable Non-Invasive Blood Glucose Monitoring Device
    Buda, R. A.
    Addi, M. Mohd
    2014 IEEE CONFERENCE ON BIOMEDICAL ENGINEERING AND SCIENCES (IECBES), 2014, : 964 - 969
  • [48] Ultrasonic device developed for non-invasive moxibustion therapy
    Kim, Geonwoo
    Hwang, Young-In
    Ryu, Yeonhee
    Kim, Hak-Joon
    Bae, Young-Min
    Kim, Ki-Bok
    INTEGRATIVE MEDICINE RESEARCH, 2021, 10 (04)
  • [49] A device for non-invasive electrical stimulation of the phrenic nerve
    Li, R. V.
    Potrakhov, N. N.
    Ukhov, A. A.
    Shapovalov, S. V.
    Mazurok, V. A.
    Karpov, A. A.
    Akhmetova, A. A.
    BIOMEDICAL ENGINEERING, 2024, 57 (06) : 367 - 370
  • [50] AATiENDe: Automatic ATtention Evaluation on a Non-invasive Device
    Escalona, Felix
    Gomez-Donoso, Francisco
    Morillas-Espejo, Francisco
    Pina-Navarro, Monica
    Marquez-Carpintero, Luis
    Cazorla, Miguel
    ADVANCES IN COMPUTATIONAL INTELLIGENCE, IWANN 2023, PT II, 2023, 14135 : 157 - 168