Suppression of ghost artifacts arising from long T1 species in segmented inversion-recovery imaging

被引:5
|
作者
Jenista, Elizabeth R. [1 ]
Rehwald, Wolfgang G. [4 ]
Chaptini, Nayla H. [5 ]
Kim, Han W. [1 ,2 ]
Parker, Michele A. [1 ]
Wendell, David C. [1 ]
Chen, Enn-ling [1 ,2 ]
Kim, Raymond J. [1 ,2 ,3 ]
机构
[1] Duke Univ, Med Ctr, Duke Cardiovasc Magnet Resonance Ctr, Durham, NC USA
[2] Duke Univ, Med Ctr, Dept Med, Durham, NC 27710 USA
[3] Duke Univ, Med Ctr, Dept Radiol, Durham, NC 27710 USA
[4] Siemens Healthcare, Cardiovasc MR R&D, Chicago, IL USA
[5] Advocate Lutheran Gen Hosp, Dept Cardiol, Chicago, IL USA
关键词
delayed contrast-enhancement MRI; late gadolinium enhanced MRI; artifacts; cardiac MRI; CARDIOVASCULAR MAGNETIC-RESONANCE; MYOCARDIAL-INFARCTION; CONTRAST;
D O I
10.1002/mrm.26554
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeWe demonstrate an improved segmented inversion-recovery sequence that suppresses ghost artifacts arising from tissues with long T-1 (>1.5 s). Theory and MethodsLong T-1 species such as pericardial fluid can create bright ghost artifacts in segmented, inversion-recovery MRI because of oscillations in longitudinal magnetization between segments. A single dummy acquisition at the beginning of the sequence can reduce oscillations; however, its effectiveness in suppressing long T-1 artifacts is unknown. In this study, we systematically evaluated several test sequences, including a prototype (saturation post-pulse readout to eliminate spurious signal: SPPRESS) in simulations, phantoms, and patients. ResultsSPPRESS reduced artifact signal 90%25% and 74%+/- 28% compared with Control and Single-Dummy methods in phantoms. SPPRESS performed well at 1.5 Tesla (T) and 3T, with steady-state free precession (SSFP) and fast low-angle shot (FLASH) readout, with conventional and phase-sensitive reconstruction, and over a range of physiologic heart rates. A review of 100 consecutive clinical cardiac MRI scans revealed large fluid collections (eg, regions with long T-1) in 14% of patients. In a prospectively enrolled cohort of 16 patients with visible long T-1 fluids, SPPRESS appreciably reduced artifacts in all cases compared with Control and Single-Dummy methods. ConclusionWe developed and validated a new robust method, SPPRESS, for reducing artifacts due to long T-1 species across a wide range of imaging and physiologic conditions. Magn Reson Med 78:1442-1451, 2017. (c) 2016 International Society for Magnetic Resonance in Medicine.
引用
收藏
页码:1442 / 1451
页数:10
相关论文
共 50 条
  • [1] On the cause of spatial displacement of long T1 species in segmented inversion recovery prepared imaging
    Goldfarb, JW
    Arnold, S
    Schapiro, W
    Reichek, N
    MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (02) : 481 - 485
  • [2] A new method to suppress ghosting artifacts arising from long-T1 species in segmented inversion recovery (IR) sequences
    Nayla Chaptini
    Wolfgang G Rehwald
    Elizabeth R Jenista
    Michele A Parker
    Enn-Ling Chen
    Raymond J Kim
    Journal of Cardiovascular Magnetic Resonance, 13 (Suppl 1)
  • [3] MEASUREMENT OF T1 USING THE MULTIPLE INVERSION-RECOVERY SEQUENCE
    YOUNG, IR
    BYDDER, GM
    COLLINS, AG
    HALL, AS
    BRITISH JOURNAL OF RADIOLOGY, 1987, 60 (716): : 788 - 788
  • [4] 2-STAGE INVERSION-RECOVERY EXPERIMENTS FOR MEASUREMENTS OF T1
    TAITELBAUM, H
    FERRETTI, JA
    SPENCER, RGS
    WEISS, GH
    JOURNAL OF MAGNETIC RESONANCE SERIES A, 1993, 105 (01) : 59 - 64
  • [5] MULTISLICE INVERSION-RECOVERY T1 DETERMINATION USING OPTIMIZED PULSES
    ROBERTS, TPL
    CARPENTER, TA
    HALL, LD
    JOURNAL OF MAGNETIC RESONANCE, 1991, 94 (01): : 160 - 164
  • [6] THE CHOICE OF PARAMETERS IN AN NMR EXPERIMENT - APPLICATION TO THE INVERSION-RECOVERY T1 METHOD
    BAIN, AD
    JOURNAL OF MAGNETIC RESONANCE, 1990, 89 (01): : 153 - 160
  • [7] Optimized precision of inversion-recovery T1 measurements for constrained scan time
    Ogg, RJ
    Kingsley, PB
    MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (03) : 625 - 630
  • [8] EVALUATION OF THE INVERSION-RECOVERY AND DESPOT METHODS FOR MEASUREMENT OF T1 OF THE POLYSACCHARIDE PULLULAN
    HOFFMAN, RE
    DAVIES, DB
    JOURNAL OF MAGNETIC RESONANCE, 1988, 80 (02): : 318 - 323
  • [9] T1-insensitive flow suppression using quadruple inversion-recovery
    Yarnykh, VL
    Yuan, C
    MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (05) : 899 - 905
  • [10] HIGH-SPEED MULTISLICE T1 MAPPING USING INVERSION-RECOVERY ECHO-PLANAR IMAGING
    ORDIDGE, RJ
    GIBBS, P
    CHAPMAN, B
    STEHLING, MK
    MANSFIELD, P
    MAGNETIC RESONANCE IN MEDICINE, 1990, 16 (02) : 238 - 245