Ultrasound research scanner for real-time synthetic aperture data acquisition

被引:130
|
作者
Jensen, JA [1 ]
Holm, O
Jensen, LJ
Bendsen, H
Nikolov, SI
Tomov, BG
Munk, P
Hansen, M
Salomonsen, K
Hansen, J
Gormsen, K
Pedersen, HM
Gammelmark, KL
机构
[1] Tech Univ Denmark, Ctr Fast Ultrasound Imaging, DK-2800 Lyngby, Denmark
[2] IO Technol A S, DK-2500 Copenhagen, Denmark
关键词
D O I
10.1109/TUFFC.2005.1503974
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Conventional ultrasound systems acquire ultrasound data sequentially one image line at a time. The architecture of these systems is therefore also sequential in nature and processes most of the data in a sequential pipeline. This often makes it difficult to implement radically different imaging strategies on the platforms and makes the scanners less accessible for research purposes. A system designed for imaging research flexibility is the prime concern. The possibility of sending out arbitrary signals and the storage of data from all transducer elements for 5 to 10 seconds allows clinical evaluation of synthetic aperture and 3D imaging. This paper describes a real-time system specifically designed for research purposes. The system can acquire multichannel data in real-time from multi-element ultrasound transducers, and can perform some real-time processing on the acquired data. The system is capable of performing real-time beamforming for conventional imaging methods using linear, phased, and convex arrays. Image acquisition modes can be intermixed, and this makes it possible to perform initial trials in a clinical environment with new imaging modalities for synthetic aperture imaging, 2D and 3D B-mode, and velocity imaging using advanced coded emissions. The system can be used with 128-element transducers and can excite 128 transducer elements and receive and sample data from 64 channels simultaneously at 40 MHz with 12-bit precision. Two-to-one multiplexing in receive can be used to cover 128 receive channels. Data can be beamformed in real time using the system's 80 signal processing units, or it can be stored directly in RAM. The system has 16 Gbytes RAM and can, thus, store more than 3.4 seconds of multichannel data. It is fully software programmable and its signal processing units can also be reconfigured under software control. The control of the system is done over a 100-Mbits/s Ethernet using C and Matlab. Programs for doing, e.g., B-mode imaging can be written directly in Matlab and executed on the system over the net from any workstation running Matlab. The overall system concept is presented along with its implementation and examples of B-mode and in vivo synthetic aperture flow imaging.
引用
收藏
页码:881 / 891
页数:11
相关论文
共 50 条
  • [21] In Vivo Real Time Volumetric Synthetic Aperture Ultrasound Imaging
    Bouzari, Hamed
    Rasmussen, Morten Fisher
    Brandt, Andreas Hjelm
    Stuart, Matthias Bo
    Nikolov, Svetoslav
    Jensen, Jorgen Arendt
    [J]. MEDICAL IMAGING 2015: ULTRASONIC IMAGING AND TOMOGRAPHY, 2015, 9419
  • [22] High-resolution imaging with a real-time synthetic aperture ultrasound system: A phantom study
    Huang, Lianjie
    Labyed, Yassin
    Simonetti, Francesco
    Williamson, Michael
    Rosenberg, Robert
    Heintz, Philip
    Sandoval, Daniel
    [J]. MEDICAL IMAGING 2011: ULTRASONIC IMAGING, TOMOGRAPHY, AND THERAPY, 2011, 7968
  • [23] Real-time 3-D ultrasound imaging using sparse synthetic aperture beamforming
    Lockwood, GR
    Talman, JR
    Brunke, SS
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1998, 45 (04) : 980 - 988
  • [24] Quantifiable real-time 3D ultrasound data acquisition and visualization
    Welch, JN
    Johnson, J
    Badr, R
    Bax, M
    So, S
    Krummel, T
    Shahidi, R
    [J]. CARS 2001: COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2001, 1230 : 1155 - 1155
  • [25] REAL-TIME DATA ACQUISITION AND INTERPRETATION CAPABILITIES OF THE DYNASONDE .1. DATA ACQUISITION AND REAL-TIME DISPLAY
    WRIGHT, JW
    PITTEWAY, MLV
    [J]. RADIO SCIENCE, 1979, 14 (05) : 815 - 825
  • [26] Research of Power Grid's Real-Time Data Acquisition and Monitoring
    Xiong, Guohai
    Liu, Xinyun
    [J]. 2016 INTERNATIONAL CONFERENCE ON NETWORK AND INFORMATION SYSTEMS FOR COMPUTERS (ICNISC), 2016, : 177 - 179
  • [27] CONCEPTS AND TECHNIQUES FOR REAL-TIME OPTICAL SYNTHETIC APERTURE RADAR DATA-PROCESSING
    DANIEL, CD
    [J]. IEE PROCEEDINGS-J OPTOELECTRONICS, 1986, 133 (01): : 7 - 25
  • [28] DIAGNOSIS OF NEONATAL CONVULSIONS USING A REAL-TIME ULTRASOUND SCANNER
    YOKOTA, K
    HIRATA, T
    [J]. BRAIN & DEVELOPMENT, 1984, 6 (02): : 180 - 180
  • [29] THE IMPACT OF THE EMISONIC 4500 REAL-TIME SCANNER IN ABDOMINAL ULTRASOUND
    COSGROVE, DO
    PUSSELL, SJ
    MELLER, S
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1980, 53 (630): : 618 - 618
  • [30] A Real-time Streaming DAQ for Ultrasonix Research Scanner
    Walczak, Mateusz
    Lewandowski, Marcin
    Zolek, Norbert
    [J]. 2014 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2014, : 1257 - 1260