The influence of axial-flow fan trailing edge structure on internal flow

被引:4
|
作者
Zhang, Weijie [1 ]
Yuan, Jianping [1 ]
Zhou, Banglun [1 ]
Li, Hao [1 ]
Yuan, Ye [1 ]
机构
[1] Jiangsu Univ, Natl Res Ctr Pumps, Zhenjiang 212013, Jiangsu, Peoples R China
关键词
Axial-flow fan; internal flow; pressure fluctuation; trailing edge structure;
D O I
10.1177/1687814018811745
中图分类号
O414.1 [热力学];
学科分类号
摘要
Axial-flow fan with advantages such as large air volume, high head pressure, and low noise is commonly used in the work of air-conditioner outdoor unit. In order to investigate the internal flow mechanism of the axial-flow fan with different trailing edge structures of impellers, four kinds of impellers were designed, and numerical simulation and experiment were deployed in this article. The pressure distribution on the blades surface and distribution of vorticity in impellers were obtained using numerical simulation. Distribution of blade loading and velocity at the circumference are discussed. The relationship between the wideband noise and the trailing edge was established based on the experiment results. The results show that after the optimization of the trailing edge structure, the distribution of vorticity near the trailing edge of the blade is more uniform, especially at the trailing edge of 80% of the chord length of the suction surface. From the blade height position of 70% to the impeller tip, the pressure on the surface rapidly increases due to the tip vortex and the vortex shedding on the blade edge occurred in the top region of impeller. The pressure fluctuation amplitude at the trailing edge structure of the tail-edge optimization structure is smaller. In the distribution of blade loading, the three tail-edge optimization structures have smaller pressure fluctuations and pressure differences at the trailing edge structure. It is extremely important to control the fluctuation amplitude at the trailing edge. The amplitude of low-frequency sound pressure level of optimizing the trailing edge structure decreases obviously in the range of 50-125 Hz, and the optimization structure of trailing edge has an obvious effect on low-frequency wideband noise.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] STUDY ON THE SECONDARY FLOW IN THE DOWNSTREAM OF A MOVING BLADE ROW IN AN AXIAL-FLOW FAN
    ADACHI, T
    SASHIKUMA, H
    KAWAI, T
    BULLETIN OF THE JSME-JAPAN SOCIETY OF MECHANICAL ENGINEERS, 1981, 24 (188): : 332 - 339
  • [32] Investigation into the Influence of Division Pier on the Internal Flow and Pulsation in the Outlet Conduit of an Axial-Flow Pump
    Yang, Fan
    Jiang, Dongjin
    Wang, Tieli
    Chang, Pengcheng
    Liu, Chao
    Liu, Dongsheng
    APPLIED SCIENCES-BASEL, 2021, 11 (15):
  • [33] The aerodynamic design and experimental research on high-speed axial-flow fan applied in the axial-flow pneumatic extinguisher
    Chu, Shuang-Lei
    Yu, Guo-Sheng
    Qin, Rui-Hong
    Kongqi Donglixue Xuebao/Acta Aerodynamica Sinica, 2010, 28 (05): : 565 - 570
  • [34] Investigation on Unsteady Flow Characteristics in an Axial-Flow Fan under Stall Conditions
    Jiang, Chenlong
    Li, Mengjiao
    Li, Enda
    Zhu, Xingye
    PROCESSES, 2020, 8 (08)
  • [35] Performance Degradation and Flow Instability of Axial-Flow Fan Due to Upstream Obstacle
    Kang, Donghyuk
    Shinohara, Takeru
    Nakamura, Shinsaku
    Nishibe, Koichi
    Sato, Kotaro
    Yokota, Kazuhiko
    Ohue, Hiroshi
    JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 2020, 142 (09):
  • [36] A STUDY ON THE FLOW WITHIN THE FLOW PASSAGE OF AN AXIAL-FLOW FAN EQUIPPED WITH AIR-SEPARATOR
    MIYAKE, Y
    INABA, T
    NISHIKAWA, Y
    NOJI, I
    KATO, T
    BULLETIN OF THE JSME-JAPAN SOCIETY OF MECHANICAL ENGINEERS, 1986, 29 (256): : 3394 - 3401
  • [37] The Influence of a Blade-Guiding Fin on the Pneumatic Performance of an Axial-Flow Cooling Fan
    Shu, Hengtao
    Chen, Haizhou
    MACHINES, 2023, 11 (04)
  • [38] MEASUREMENT OF DIPOLE SOURCE DISTRIBUTIONS ON COMPONENTS OF AN AXIAL-FLOW FAN
    LEGGAT, LJ
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1974, 55 (02): : 387 - 387
  • [39] Quantification and control of noise sources in a small axial-flow fan
    Wang, Jian
    Huang, Lixi
    NOISE CONTROL ENGINEERING JOURNAL, 2006, 54 (01) : 27 - 32
  • [40] SUBSONIC AXIAL-FLOW FAN NOISE AND INFLOW VELOCITY DISTURBANCE
    CHIU, WS
    LAUCHLE, GC
    ENGINEERING FOR ENVIRONMENTAL NOISE CONTROL, VOLS 1 AND 2: INTER-NOISE 89, 1989, : 133 - 138