Direct detection of acetylene in air by continuous wave cavity ring-down spectroscopy

被引:20
|
作者
Schmidt, F. M. [1 ]
Vaittinen, O. [1 ]
Metsala, M. [1 ]
Kraus, P. [1 ]
Halonen, L. [1 ]
机构
[1] Univ Helsinki, Dept Chem, Phys Chem Lab, Helsinki 00014, Finland
来源
APPLIED PHYSICS B-LASERS AND OPTICS | 2010年 / 101卷 / 03期
基金
芬兰科学院;
关键词
VOLATILE ORGANIC-COMPOUNDS; NEAR-INFRARED REGION; SAMPLE PRECONCENTRATION; OUTPUT SPECTROSCOPY; AMBIENT AIR; NICE-OHMS; C2H2; VOC; SPECTROMETRY; SENSITIVITY;
D O I
10.1007/s00340-010-4027-5
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Diode laser-based continuous wave cavity ring-down spectroscopy (cw-CRDS) in the near-infrared region has been used to measure the mixing ratio of acetylene (C2H2) in ambient air. Detection limits of 120 parts per trillion by volume (pptv) for 20 min and 340 pptv for 70 s acquisition time were achieved without sample pre-concentration, measuring on a C2H2 absorption line at 6565.620 cm(-1) (similar to 1523 nm). Several indoor and outdoor air samples were collected at different locations in the Helsinki metropolitan area and analyzed using static-cell measurements. In addition, flow measurements of indoor and outdoor air have been performed continuously over several days with a time resolution of down to one minute. Baseline acetylene levels in the range of 0.4 to 3 parts per billion by volume (ppbv), with a maximum around midday and a minimum during the night, were measured. Sudden high mixing ratios of up to 60 ppbv were observed in outdoor air during daytime on a minute time scale. In general, the indoor mixing ratios were found to be higher than those in outdoor air. The acetylene levels correlated with the ambient CO levels and with outdoor temperature.
引用
收藏
页码:671 / 682
页数:12
相关论文
共 50 条
  • [21] Detection of sputtered metals with cavity ring-down spectroscopy
    Yalin, AP
    Surla, V
    Butweiller, M
    Williams, JD
    APPLIED OPTICS, 2005, 44 (30) : 6496 - 6505
  • [22] Cavity ring-down spectroscopy for the detection of atomic beams
    Castro, Alonso
    Wei, Wei
    NOVEL OPTICAL SYSTEMS, METHODS, AND APPLICATIONS XXV, 2022, 12216
  • [23] Cavity ring-down spectroscopy for trace ammonia detection
    Qu Zhe-Chao
    Li Bin-Cheng
    Han Yan-Ling
    JOURNAL OF INFRARED AND MILLIMETER WAVES, 2012, 31 (05) : 431 - 436
  • [24] Optical heterodyne detection in cavity ring-down spectroscopy
    Levenson, MD
    Paldus, BA
    Spence, TG
    Harb, CC
    Harris, JS
    Zare, RN
    CHEMICAL PHYSICS LETTERS, 1998, 290 (4-6) : 335 - 340
  • [25] Numerical methods of mode selection in continuous-wave cavity ring-down spectroscopy
    Wang Jin-Duo
    Yu Jin
    Mo Ze-Qiang
    He Jian-Guo
    Dai Shou-Jun
    Meng Jing-Jing
    Wang Xiao-Dong
    Liu Yang
    ACTA PHYSICA SINICA, 2019, 68 (24)
  • [26] Direct monitoring of absorption in solution by cavity ring-down spectroscopy
    Hallock, AJ
    Berman, ESF
    Zare, RN
    ANALYTICAL CHEMISTRY, 2002, 74 (07) : 1741 - 1743
  • [27] Lamb-dip cavity ring-down spectroscopy of acetylene at 1.4 μm
    Fasci, E.
    Gravina, S.
    Porzio, G.
    Castrillo, A.
    Gianfrani, L.
    NEW JOURNAL OF PHYSICS, 2021, 23 (12):
  • [28] Evanescent wave cavity ring-down spectroscopy for ultra-sensitive chemical detection
    Pipino, ACR
    ADVANCED SENSORS AND MONITORS FOR PROCESS INDUSTRIES AND THE ENVIRONMENT, 1999, 3535 : 57 - 67
  • [29] Mid-infrared continuous wave cavity ring-down spectroscopy of a pulsed hydrocarbon plasma
    Zhao, Dongfeng
    Guss, Joseph
    Walsh, Anton J.
    Linnartz, Harold
    CHEMICAL PHYSICS LETTERS, 2013, 565 : 132 - 137
  • [30] Differential cavity ring-down spectroscopy
    Courtois, Jeromie
    Bielska, Katarzyna
    Hodges, Joseph T.
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 2013, 30 (06) : 1486 - 1495