Direct detection of acetylene in air by continuous wave cavity ring-down spectroscopy

被引:20
|
作者
Schmidt, F. M. [1 ]
Vaittinen, O. [1 ]
Metsala, M. [1 ]
Kraus, P. [1 ]
Halonen, L. [1 ]
机构
[1] Univ Helsinki, Dept Chem, Phys Chem Lab, Helsinki 00014, Finland
来源
APPLIED PHYSICS B-LASERS AND OPTICS | 2010年 / 101卷 / 03期
基金
芬兰科学院;
关键词
VOLATILE ORGANIC-COMPOUNDS; NEAR-INFRARED REGION; SAMPLE PRECONCENTRATION; OUTPUT SPECTROSCOPY; AMBIENT AIR; NICE-OHMS; C2H2; VOC; SPECTROMETRY; SENSITIVITY;
D O I
10.1007/s00340-010-4027-5
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Diode laser-based continuous wave cavity ring-down spectroscopy (cw-CRDS) in the near-infrared region has been used to measure the mixing ratio of acetylene (C2H2) in ambient air. Detection limits of 120 parts per trillion by volume (pptv) for 20 min and 340 pptv for 70 s acquisition time were achieved without sample pre-concentration, measuring on a C2H2 absorption line at 6565.620 cm(-1) (similar to 1523 nm). Several indoor and outdoor air samples were collected at different locations in the Helsinki metropolitan area and analyzed using static-cell measurements. In addition, flow measurements of indoor and outdoor air have been performed continuously over several days with a time resolution of down to one minute. Baseline acetylene levels in the range of 0.4 to 3 parts per billion by volume (ppbv), with a maximum around midday and a minimum during the night, were measured. Sudden high mixing ratios of up to 60 ppbv were observed in outdoor air during daytime on a minute time scale. In general, the indoor mixing ratios were found to be higher than those in outdoor air. The acetylene levels correlated with the ambient CO levels and with outdoor temperature.
引用
收藏
页码:671 / 682
页数:12
相关论文
共 50 条
  • [1] Direct detection of acetylene in air by continuous wave cavity ring-down spectroscopy
    F. M. Schmidt
    O. Vaittinen
    M. Metsälä
    P. Kraus
    L. Halonen
    Applied Physics B, 2010, 101 : 671 - 682
  • [2] Sensitivity Limits of Continuous Wave Cavity Ring-Down Spectroscopy
    Huang, Haifeng
    Lehmann, Kevin K.
    JOURNAL OF PHYSICAL CHEMISTRY A, 2013, 117 (50): : 13399 - 13411
  • [3] Trace moisture detection using continuous-wave cavity ring-down spectroscopy
    Dudek, JB
    Tarsa, PB
    Velasquez, A
    Wladyslawski, M
    Rabinowitz, P
    Lehmann, KK
    ANALYTICAL CHEMISTRY, 2003, 75 (17) : 4599 - 4605
  • [4] Development and Applications of Continuous-Wave Cavity Ring-Down Spectroscopy
    W. B. Yan
    Y. Chen
    H. Chen
    C. Krusen
    P. T. Woods
    International Journal of Thermophysics, 2008, 29 : 1567 - 1577
  • [5] Development and applications of continuous-wave cavity ring-down spectroscopy
    Yan, W. B.
    Chen, Y.
    Chen, H.
    Krusen, C.
    Woods, P. T.
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2008, 29 (05) : 1567 - 1577
  • [6] Trace detection of methane using continuous wave cavity ring-down spectroscopy at 1.65 μm
    Fawcett, BL
    Parkes, AM
    Shallcross, DE
    Orr-Ewing, AJ
    PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2002, 4 (24) : 5960 - 5965
  • [7] Cavity ring-down spectroscopy of acetylene near 0.8 μm
    Lyulin, O. M.
    Liu, G. -L
    Liu, A. -W
    Tan, Y.
    Perevalov, V.
    Hu, S. -M
    JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 2024, 328
  • [8] Evanescent wave cavity ring-down spectroscopy for trace water detection
    Pipino, ACR
    Hodges, JT
    ADVANCED ENVIRONMENTAL AND CHEMICAL SENSING TECHNOLOGY, 2001, 4205 : 1 - 11
  • [9] Continuous wave cavity ring-down spectroscopy measurement of NO2 mixing ratios in ambient air
    Wada, R
    Orr-Ewing, AJ
    ANALYST, 2005, 130 (12) : 1595 - 1600
  • [10] Sensitivity Limit of Rapidly Swept Continuous Wave Cavity Ring-Down Spectroscopy
    Huang, Haifeng
    Lehmann, Kevin K.
    JOURNAL OF PHYSICAL CHEMISTRY A, 2011, 115 (34): : 9411 - 9421