Different energy balances for the redesign of nearly net zero energy buildings: An Italian case study

被引:65
|
作者
Cellura, Maurizio [1 ]
Guarino, Francesco [1 ]
Longo, Sonia [1 ]
Mistretta, Marina [2 ]
机构
[1] Univ Palermo, Dipartimento Energia Ingn Informaz & Modern Matem, I-90128 Palermo, Italy
[2] Univ Mediterranea Reggio Calabria, Dipartimento Patrimonio, Architettura, Urbanist, Reggio Di Calabria, Italy
来源
RENEWABLE & SUSTAINABLE ENERGY REVIEWS | 2015年 / 45卷
关键词
Building simulation; Net Zero Energy Building; Redesign; Sensitivity analysis; TRNSYS energy balance; Weighting factors; Primary energy; SPEED SPATIAL ESTIMATION; SINGLE-FAMILY HOUSE; SUSTAINABILITY ASSESSMENT; LIFE-CYCLE; ENVIRONMENTAL BENEFITS; CONSUMPTION; RETROFIT; DESIGN; PERFORMANCE; COMFORT;
D O I
10.1016/j.rser.2015.01.048
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The currently developing concept of a Net Zero Energy Building introduces new challenges and research problems. The calculation of a net zero energy balance is heavily influenced by the energy carrier weighting factors that are chosen, which can deeply influence the future energy market towards adopting specific energy technologies. The following paper proposes an analysis of different definitions and conventions for Net Zero Energy Buildings that employ different calculation methodologies and apply different weighting factors to an Italian case study. The case study, which is called "the Leaf House", is one of the first examples of a nearly net zero energy building in Italy. A building simulation and model calibration were performed using monitored data. Energy balances were calculated for the case study. Scenarios for a building redesign were then proposed, with the aim of reaching an electricity target of net zero energy. Reaching a primary energy building balance of net zero is easier when using symmetric weighting because it allows renewable energy to account for avoided national mix energy generation. The results show that symmetrical balances are nearly fulfilled for the existing building and asymmetrical ones are below zero. In the redesign scenarios, the symmetrical weighting scenarios exceed the zero target by 34.10 and 20.83 MWh/year. The asymmetrically weighted balances show a variable trend in that auto-consumption and high load-matching are highly favourable because the theoretical 'zero auto-consumption' scenario would yield the worst result and would be the only one below the Net Zero threshold. Although symmetric weighting approaches could be viewed as robust physical approaches for renewables (e.g., the primary energy conversion factors for PV are usually close to 1), they can become a heavy burden during the market development of renewable energy technologies, highly favouring auto-consumption and energy storage to minimise energy import from the grid. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:100 / 112
页数:13
相关论文
共 50 条
  • [21] ENERGY BALANCE FRAMEWORK FOR NET ZERO ENERGY BUILDINGS
    Srinivasan, Ravi S.
    Braham, William W.
    Campbell, Daniel P.
    Curcija, Charlie D.
    PROCEEDINGS OF THE 2011 WINTER SIMULATION CONFERENCE (WSC), 2011, : 3360 - 3372
  • [22] Advanced Innovative Solutions for Final Design in Terms of Energy Sustainability of Nearly/Net Zero Energy Buildings (nZEB)
    Mazzeo, Domenico
    Oliveti, Giuseppe
    SUSTAINABILITY, 2020, 12 (24)
  • [23] Energy Router Based Energy Management System for Nearly Zero Energy Buildings
    Najafzadeh, Mahdiyyeh
    Roasto, Indrek
    Jalakas, Tanel
    2019 IEEE 60TH INTERNATIONAL SCIENTIFIC CONFERENCE ON POWER AND ELECTRICAL ENGINEERING OF RIGA TECHNICAL UNIVERSITY (RTUCON), 2019,
  • [24] The applicability of nearly/net zero energy residential buildings in Brazil - A study of a low standard dwelling in three different Brazilian climate zones
    Resende, Jaime
    Monzon-Chavarrias, Marta
    Corvacho, Helena
    INDOOR AND BUILT ENVIRONMENT, 2021, 30 (10) : 1693 - 1713
  • [25] The Redesign of an Italian Building to Reach Net Zero Energy Performances: A Case Study of the SHC Task 40-ECBCS Annex 52
    Cellura, Maurizio
    Campanella, Lucia
    Ciulla, Giuseppina
    Guarino, Francesco
    Lo Brano, Valerio
    Cesarini, Davide Nardi
    Orioli, Aldo
    ASHRAE TRANSACTIONS 2011, VOL 117, PT 2, 2011, 117 : 331 - 339
  • [26] Nearly Zero-Energy Refurbished Buildings (nZERBs) : A Case Study of an Historical University Departement
    Loggia, Riccardo
    Flamini, Alessandro
    Massaccesi, Andrea
    Moscatiello, Cristina
    Martirano, Luigi
    2022 IEEE/IAS 58TH INDUSTRIAL AND COMMERCIAL POWER SYSTEMS TECHNICAL CONFERENCE (I&CPS), 2022,
  • [27] Impact of financial assumptions on the cost optimality towards nearly zero energy buildings - A case study
    Hamdy, Mohamed
    Siren, Kai
    Attia, Shady
    ENERGY AND BUILDINGS, 2017, 153 : 421 - 438
  • [28] A Case Study of a Renovation of a Historical University Department: The Nearly Zero-Energy Refurbished Buildings
    Loggia, Riccardo
    Flamini, Alessandro
    Massaccesi, Andrea
    Moscatiello, Cristina
    Martirano, Luigi
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2022, 58 (06) : 6970 - 6980
  • [29] A study on thermoelectric technology application in net zero energy buildings
    Shen, Limei
    Pu, Xiwang
    Sun, Yongjun
    Chen, Jiongde
    ENERGY, 2016, 113 : 9 - 24
  • [30] Data on energy consumption and Nearly zero energy buildings (NZEBs) in Europe
    D'Agostino, Delia
    Mazzarella, Livio
    DATA IN BRIEF, 2018, 21 : 2470 - 2474