A new streaked soft x-ray imager for the National Ignition Facility

被引:6
|
作者
Benstead, J. [1 ]
Moore, A. S. [2 ]
Ahmed, M. F. [2 ]
Morton, J. [1 ]
Guymer, T. M. [1 ]
Soufli, R. [2 ]
Pardini, T. [2 ]
Hibbard, R. L. [2 ]
Bailey, C. G. [2 ]
Bell, P. M. [2 ]
Hau-Riege, S. [2 ]
Bedzyk, M. [3 ]
Shoup, M. J., III [3 ]
Reagan, S. [3 ]
Agliata, T. [3 ]
Jungquist, R. [3 ]
Schmidt, D. W. [4 ]
Kot, L. B. [4 ]
Garbett, W. J. [1 ]
Rubery, M. S. [1 ]
Skidmore, J. W. [1 ]
Gullikson, E. [5 ]
Salmassi, F. [5 ]
机构
[1] AWE, Reading RG7 4PR, Berks, England
[2] Lawrence Livermore Natl Lab, Livermore, CA 94550 USA
[3] Univ Rochester, Laser Energet Lab, Rochester, NY 14623 USA
[4] Los Alamos Natl Lab, Los Alamos, NM 87545 USA
[5] Lawrence Berkeley Natl Lab, Berkeley, CA 94720 USA
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2016年 / 87卷 / 05期
关键词
TRANSMISSION;
D O I
10.1063/1.4951689
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A new streaked soft x-ray imager has been designed for use on high energy-density (HED) physics experiments at the National Ignition Facility based at the Lawrence Livermore National Laboratory. This streaked imager uses a slit aperture, single shallow angle reflection from a nickel mirror, and soft x-ray filtering to, when coupled to one of the NIF's x-ray streak cameras, record a 4x magnification, one-dimensional image of an x-ray source with a spatial resolution of less than 90 mu m. The energy band pass produced depends upon the filter material used; for the first qualification shots, vanadium and silver-on-titanium filters were used to gate on photon energy ranges of approximately 300-510 eV and 200-400 eV, respectively. A two-channel version of the snout is available for x-ray sources up to 1 mm and a single-channel is available for larger sources up to 3 mm. Both the one and two-channel variants have been qualified on quartz wire and HED physics target shots.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] Long duration x-ray source development for x-ray diffraction at the National Ignition Facility
    Werellapatha, K.
    Hall, G. N.
    Coppari, F.
    Kemp, G. E.
    Palmer, N. E.
    Krauland, C.
    Khan, S. F.
    Lazicki, A.
    Gorman, M. G.
    Nagel, S. R.
    Heinbockel, C.
    Bhandarkar, N.
    Masters, N.
    Bradley, D. K.
    Eggert, J. H.
    Benedetti, L. R.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2021, 92 (05):
  • [22] Observation of High Soft X-Ray Drive in Large-Scale Hohlraums at the National Ignition Facility
    Kline, J. L.
    Glenzer, S. H.
    Olson, R. E.
    Suter, L. J.
    Widmann, K.
    Callahan, D. A.
    Dixit, S. N.
    Thomas, C. A.
    Hinkel, D. E.
    Williams, E. A.
    Moore, A. S.
    Celeste, J.
    Dewald, E.
    Hsing, W. W.
    Warrick, A.
    Atherton, J.
    Azevedo, S.
    Beeler, R.
    Berger, R.
    Conder, A.
    Divol, L.
    Haynam, C. A.
    Kalantar, D. H.
    Kauffman, R.
    Kyrala, G. A.
    Kilkenny, J.
    Liebman, J.
    Le Pape, S.
    Larson, D.
    Meezan, N. B.
    Michel, P.
    Moody, J.
    Rosen, M. D.
    Schneider, M. B.
    Van Wonterghem, B.
    Wallace, R. J.
    Young, B. K.
    Landen, O. L.
    MacGowan, B. J.
    PHYSICAL REVIEW LETTERS, 2011, 106 (08)
  • [23] The PERCIVAL soft X-ray imager
    Wunderer, C. B.
    Marras, A.
    Bayer, M.
    Correa, J.
    Goettlicher, P.
    Lange, S.
    Shevyakov, I.
    Smoljanin, S.
    Tennert, M.
    Viti, M.
    Xia, Q.
    Zimmer, M.
    Das, D.
    Guerrini, N.
    Marsh, B.
    Sedgwick, I.
    Turchetta, R.
    Cautero, G.
    Gianoncelli, A.
    Giuressi, D.
    Menk, R.
    Stebel, L.
    Yousef, H.
    Marchal, J.
    Rees, N.
    Tartoni, N.
    Graafsma, H.
    JOURNAL OF INSTRUMENTATION, 2015, 10
  • [24] The PERCIVAL soft X-ray imager
    Wunderer, C. B.
    Marras, A.
    Bayer, M.
    Glaser, L.
    Goettlicher, P.
    Lange, S.
    Pithan, F.
    Scholz, F.
    Seltmann, J.
    Shevyakov, I.
    Smoljanin, S.
    Viefhaus, J.
    Viti, M.
    Xia, Q.
    Zimmer, M.
    Klumpp, S.
    Gasiorek, P.
    Guerrini, N.
    Marsh, B.
    Sedgwick, I.
    Turchetta, R.
    Cautero, G.
    Farina, S.
    Giuressi, D.
    Menk, R.
    Stebel, L.
    Yousef, H.
    Marchal, J.
    Nicholls, T.
    Tartoni, N.
    Graafsma, H.
    JOURNAL OF INSTRUMENTATION, 2014, 9
  • [25] PERCIVAL Soft X-Ray Imager
    Graafsma, H.
    Wunderer, C. B.
    Marras, A.
    Viefhaus, J.
    Lange, S.
    Viti, M.
    Bayer, M.
    Hirsemann, H.
    Nilson, B.
    Smoljanin, S.
    Shevyakov, I.
    Zimmer, M.
    Goettlicher, P.
    Turchetta, R.
    Guerrini, N.
    Marsh, B.
    Sedgwick, I.
    Gasiorek, P.
    Menk, R.
    Stebel, L.
    Farina, S.
    Yousef, H.
    Cautero, G.
    Giuressi, D.
    Tartoni, N.
    Marchal, J.
    Nicholls, T.
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [26] A soft X-ray imager for MIRAX
    Zand, Jean in 't
    Mels, Wim
    Heise, John
    TRANSIENT MILKY WAY: A PERSPECTIVE FOR MIRAX, 2006, 840 : 8 - +
  • [27] X-ray drive of beryllium capsule implosions at the National Ignition Facility
    Wilson, D. C.
    Yi, S. A.
    Simakov, A. N.
    Kline, J. L.
    Kyrala, G. A.
    Dewald, E. L.
    Tommasini, R.
    Ralph, J. E.
    Olson, R. E.
    Strozzi, D. J.
    Celliers, P. M.
    Schneider, M. B.
    MacPhee, A. G.
    Zylstra, A. B.
    Callahan, D. A.
    Hurricane, O. A.
    Milovich, J. L.
    Hinkel, D. E.
    Rygg, J. R.
    Rinderknecht, H. G.
    Sio, H.
    Perry, T. S.
    Batha, S.
    9TH INTERNATIONAL CONFERENCE ON INERTIAL FUSION SCIENCES AND APPLICATIONS (IFSA 2015), 2016, 717
  • [28] Two-color spatial and temporal temperature measurements using a streaked soft x-ray imager
    Moore, A. S.
    Benstead, J.
    Ahmed, M. F.
    Morton, J.
    Guymer, T. M.
    Soufli, R.
    Pardini, T.
    Hibbard, R. L.
    Bailey, C. G.
    Bell, P. M.
    Hau-Riege, S.
    Bedzyk, M.
    Shoup, M. J., III
    Regan, S. P.
    Agliata, T.
    Jungquist, R.
    Schmidt, D. W.
    Kot, L. B.
    Garbett, W. J.
    Rubery, M. S.
    Skidmore, J. W.
    Gullikson, E.
    Salmassi, F.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (11):
  • [29] Demonstration of a long pulse X-ray source at the National Ignition Facility
    May, M. J.
    Opachich, Y. P.
    Kemp, G. E.
    Colvin, J. D.
    Barrios, M. A.
    Widmann, K. W.
    Fournier, K. B.
    Hohenberger, M.
    Albert, F.
    Regan, S. P.
    PHYSICS OF PLASMAS, 2017, 24 (04)
  • [30] X-Ray Penumbral Imaging Diagnostic Developments at the National Ignition Facility
    Bachmann, B.
    Abu-Shawareb, H.
    Alexander, N.
    Ayers, J.
    Bailey, C. G.
    Bell, P.
    Benedetti, L. R.
    Bradley, D.
    Collins, G.
    Divol, L.
    Doeppner, T.
    Felker, S.
    Field, J.
    Forsman, A.
    Galbraith, J. D.
    Hardy, C. M.
    Hilsabeck, T.
    Izumi, N.
    Jarrott, C.
    Kilkenny, J.
    Kramer, S.
    Landen, O. L.
    Ma, T.
    MacPhee, A.
    Masters, N.
    Nagel, S. R.
    Pak, A.
    Patel, P.
    Pickworth, L. A.
    Ralph, J. E.
    Reed, C.
    Rygg, J. R.
    Thorn, D. B.
    TARGET DIAGNOSTICS PHYSICS AND ENGINEERING FOR INERTIAL CONFINEMENT FUSION VI, 2017, 10390