A new streaked soft x-ray imager for the National Ignition Facility

被引:6
|
作者
Benstead, J. [1 ]
Moore, A. S. [2 ]
Ahmed, M. F. [2 ]
Morton, J. [1 ]
Guymer, T. M. [1 ]
Soufli, R. [2 ]
Pardini, T. [2 ]
Hibbard, R. L. [2 ]
Bailey, C. G. [2 ]
Bell, P. M. [2 ]
Hau-Riege, S. [2 ]
Bedzyk, M. [3 ]
Shoup, M. J., III [3 ]
Reagan, S. [3 ]
Agliata, T. [3 ]
Jungquist, R. [3 ]
Schmidt, D. W. [4 ]
Kot, L. B. [4 ]
Garbett, W. J. [1 ]
Rubery, M. S. [1 ]
Skidmore, J. W. [1 ]
Gullikson, E. [5 ]
Salmassi, F. [5 ]
机构
[1] AWE, Reading RG7 4PR, Berks, England
[2] Lawrence Livermore Natl Lab, Livermore, CA 94550 USA
[3] Univ Rochester, Laser Energet Lab, Rochester, NY 14623 USA
[4] Los Alamos Natl Lab, Los Alamos, NM 87545 USA
[5] Lawrence Berkeley Natl Lab, Berkeley, CA 94720 USA
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2016年 / 87卷 / 05期
关键词
TRANSMISSION;
D O I
10.1063/1.4951689
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A new streaked soft x-ray imager has been designed for use on high energy-density (HED) physics experiments at the National Ignition Facility based at the Lawrence Livermore National Laboratory. This streaked imager uses a slit aperture, single shallow angle reflection from a nickel mirror, and soft x-ray filtering to, when coupled to one of the NIF's x-ray streak cameras, record a 4x magnification, one-dimensional image of an x-ray source with a spatial resolution of less than 90 mu m. The energy band pass produced depends upon the filter material used; for the first qualification shots, vanadium and silver-on-titanium filters were used to gate on photon energy ranges of approximately 300-510 eV and 200-400 eV, respectively. A two-channel version of the snout is available for x-ray sources up to 1 mm and a single-channel is available for larger sources up to 3 mm. Both the one and two-channel variants have been qualified on quartz wire and HED physics target shots.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Design of the National Ignition Facility static x-ray imager
    Landon, MD
    Koch, JA
    Alvarez, SS
    Bell, PM
    Lee, FD
    Moody, JD
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2001, 72 (01): : 698 - 700
  • [2] Ignition X-ray imager for laser-fusion research at the national ignition facility
    Tommasini, R.
    Phillips, T. W.
    Koch, J. A.
    JOURNAL DE PHYSIQUE IV, 2006, 133 : 935 - 937
  • [3] eHXI: a permanently installed, hard x-ray imager for the National Ignition Facility
    Doppner, T.
    Bachmann, B.
    Albert, F.
    Bell, P.
    Burns, S.
    Celeste, J.
    Chow, R.
    Divol, L.
    Dewald, E. L.
    Hohenberger, M.
    Huntington, C. M.
    Izumi, N.
    LaCaille, G.
    Landen, O. L.
    Palmer, N.
    Park, H. -S.
    Thomas, C. A.
    JOURNAL OF INSTRUMENTATION, 2016, 11
  • [4] Dante soft x-ray power diagnostic for National Ignition Facility
    Dewald, EL
    Campbell, KM
    Turner, RE
    Holder, JP
    Landen, OL
    Glenzer, SH
    Kauffman, RL
    Suter, LJ
    Landon, M
    Rhodes, M
    Lee, D
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2004, 75 (10): : 3759 - 3761
  • [5] High energy X-ray imager for inertial confinement fusion at the National Ignition Facility
    Tommasini, Riccardo
    Koch, Jeffrey A.
    Young, Bruce
    Ng, Ed
    Phillips, Tom
    Dauffy, Lucile
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2006, 77 (10):
  • [6] X-ray diffraction at the National Ignition Facility
    Rygg, J. R.
    Smith, R. F.
    Lazicki, A. E.
    Braun, D. G.
    Fratanduono, D. E.
    Kraus, R. G.
    McNaney, J. M.
    Swift, D. C.
    Wehrenberg, C. E.
    Coppari, F.
    Ahmed, M. F.
    Barrios, M. A.
    Blobaum, K. J. M.
    Collins, G. W.
    Cook, A. L.
    Di Nicola, P.
    Dzenitis, E. G.
    Gonzales, S.
    Heidl, B. F.
    Hohenberger, M.
    House, A.
    Izumi, N.
    Kalantar, D. H.
    Khan, S. F.
    Kohut, T. R.
    Kumar, C.
    Masters, N. D.
    Polsin, D. N.
    Regan, S. P.
    Smith, C. A.
    Vignes, R. M.
    Wall, M. A.
    Ward, J.
    Wark, J. S.
    Zobrist, T. L.
    Arsenlis, A.
    Eggert, J. H.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2020, 91 (04):
  • [7] Development of CCD cameras for soft X-ray imaging at the National Ignition Facility
    Teruya, A. T.
    Palmer, N. E.
    Schneider, M. B.
    Bell, P. M.
    Sims, G.
    Toerne, K.
    Rodenburg, K.
    Croft, M.
    Haugh, M. J.
    Charest, M. R.
    Romano, E. D.
    Jacoby, K. D.
    TARGET DIAGNOSTICS PHYSICS AND ENGINEERING FOR INERTIAL CONFINEMENT FUSION II, 2013, 8850
  • [8] X-ray backlighting for the National Ignition Facility (invited)
    Landen, OL
    Farley, DR
    Glendinning, SG
    Logory, LM
    Bell, PM
    Koch, JA
    Lee, FD
    Bradley, DK
    Kalantar, DH
    Back, CA
    Turner, RE
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2001, 72 (01): : 627 - 634
  • [9] Gated x-ray detector for the National Ignition Facility
    Oertel, John A.
    Aragonez, Robert
    Archuleta, Tom
    Barnes, Cris
    Casper, Larry
    Fatherley, Valerie
    Heinrichs, Todd
    King, Robert
    Landers, Doug
    Lopez, Frank
    Sanchez, Phillip
    Sandoval, George
    Schrank, Lou
    Walsh, Peter
    Bell, Perry
    Brown, Matt
    Costa, Robert
    Holder, Joe
    Montelongo, Sam
    Pederson, Neal
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2006, 77 (10):
  • [10] Hard x-ray spectrometers for the national ignition facility
    Seely, J
    Back, C
    Deslattes, R
    Hudson, L
    Holland, G
    Bell, P
    Miller, M
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2001, 72 (06): : 2562 - 2565