Optimal timing of contrast-enhanced three-dimensional magnetic resonance left atrial angiography before pulmonary vein ablation

被引:5
|
作者
Loebe, Susanne [1 ]
Leuthaeusser, Claudia [1 ]
Poelkow, Alexander [1 ]
Hilbert, Sebastian [1 ]
Sommer, Philipp [1 ]
Bollmann, Andreas [1 ]
Hindricks, Gerhard [1 ,2 ]
Paetsch, Ingo [1 ]
Jahnke, Cosima [1 ]
机构
[1] Univ Leipzig, HELIOS Heart Ctr Leipzig, Dept Electrophysiol, Struempellstr 39, D-04289 Leipzig, Germany
[2] Leipzig Heart Inst, Leipzig, Germany
关键词
cardiovascular magnetic resonance imaging; angiography; pulmonary vein; atrial fibrillation; catheter ablation; CATHETER ABLATION; ECHOCARDIOGRAPHIC-ASSESSMENT; EUROPEAN ASSOCIATION; FIBRILLATION;
D O I
10.5603/CJ.a2019.0112
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: To achieve high image quality of cardiovascular magnetic resonance (CMR) pulmonary vein (PV) angiography prior catheter ablation in patients with atrial fibrillation, optimal timing of the angiographic sequence during contrast agent passage is important. The present study identified influential cardiovascular parameters for prediction of contrast agent travel time. Methods: One hundred six consecutive patients underwent a CMR examination including three-dimensional (3D) contrast-enhanced PV angiography with real-time bolus tracking prior to catheter ablation. Correct scan timing was characterized by relative signal enhancement measurements in the pulmonary artery, left atrium (LA), and ascending aorta. Furthermore, left- and right-ventricular function, left- and right-atrial dimensions, presence of mitral or tricuspid insufficiencies, and main pulmonary artery diameter were determined. Results: The highest relative signal enhancement in LA demonstrated optimal scan timing. Contrast agent travel time showed wide variability (range: 12-42 s; mean: 18 +/- 4 s). On univariate analysis, most cardiovascular parameters correlated with contrast agent travel time while on multivariate analysis left- and right-ventricular function remained the only independent predictors, but overall a poor fit to the data (adjusted R-2, 27.5%) was found. Conclusions: Contrast agent travel time was mainly influenced by left- and right-ventricular function but prediction models poorly fitted the data. Thus, 3D PV angiography prior to PV ablation procedures necessitates real-time assessment, with visual determination of individual contrast agent passage time to ensure consistently high CMR image quality.
引用
收藏
页码:558 / 565
页数:8
相关论文
共 50 条
  • [21] Accuracy and utility of three-dimensional contrast-enhanced magnetic resonance angiography in planning carotid stenting
    Timaran, Carlos H.
    Rosero, Eric B.
    Valentine, James
    Modrall, J. Gregory
    Smith, Stephen
    Clagett, Patrick
    JOURNAL OF VASCULAR SURGERY, 2007, 46 (02) : 257 - 263
  • [22] Budd-Chiari syndrome: Diagnosis with three-dimensional contrast-enhanced magnetic resonance angiography
    Lin, J
    Chen, XH
    Zhou, KR
    Chen, ZW
    Wang, JH
    Yan, ZP
    Wang, P
    WORLD JOURNAL OF GASTROENTEROLOGY, 2003, 9 (10) : 2317 - 2321
  • [23] DISTAL ABDOMINAL AORTIC THROMBOSIS DIAGNOSED BY THREE-DIMENSIONAL CONTRAST-ENHANCED MAGNETIC RESONANCE ANGIOGRAPHY
    Sharpley, Jenelle
    Thode, Hank
    Sestina, Lisbeth
    Park, Richard
    Monnet, Eric
    Kraft, Susan L.
    VETERINARY RADIOLOGY & ULTRASOUND, 2009, 50 (04) : 370 - 375
  • [24] Clubbing due to peripheral hypervascularization - Recognition by contrast-enhanced, three-dimensional magnetic resonance angiography
    Wiesmann, F
    Beer, M
    Krause, U
    Pabst, T
    Kenn, W
    Hahn, D
    Ertl, G
    CIRCULATION, 2001, 104 (20) : 2503 - 2503
  • [25] Comparison of three-dimensional contrast-enhanced magnetic resonance angiography and axial radiographic angiography for diagnosing congenital stenoses in small pulmonary arteries
    Kondo, C
    Takada, K
    Yokoyama, U
    Nakajima, Y
    Momma, K
    Sakai, F
    AMERICAN JOURNAL OF CARDIOLOGY, 2001, 87 (04): : 420 - 424
  • [26] Evaluation of live renal donors with three-dimensional contrast-enhanced magnetic resonance angiography in comparison to catheter angiography
    Tan, SP
    Bux, SI
    Kumar, G
    Razack, AHA
    Chua, CB
    Lee, SH
    Liew, WF
    Tan, SY
    TRANSPLANTATION PROCEEDINGS, 2004, 36 (07) : 1914 - 1916
  • [27] Three-dimensional anatomy of the left atrium by magnetic resonance angiography: Implications for catheter ablation for atrial fibrillation
    Mansour, M
    Refaat, M
    Heist, EK
    Mela, T
    Cury, R
    Holmvang, G
    Ruskin, JN
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2006, 17 (07) : 719 - 723
  • [28] Clubbing due to peripheral hypervascularization: Recognition by contrast-enhanced, three-dimensional magnetic resonance angiography - Response
    Wiesmann, F
    Eretl, G
    Beer, M
    Krause, U
    Pabst, T
    Kenn, W
    Hahn, D
    CIRCULATION, 2002, 106 (05) : E21 - E21
  • [29] Accuracy and utility of three-dimensional contrast-enhanced magnetic resonance angiography in planning carotid stenting - Discussion
    Jordan, William
    Timaran, Carlos
    JOURNAL OF VASCULAR SURGERY, 2007, 46 (02) : 263 - 264
  • [30] Cavernous transformation of the portal vein: three-dimensional dynamic contrast-enhanced MR angiography
    Wang, Li
    Li, Zhao-shen
    Lu, Jian-ping
    Wang, Fei
    Liu, Qi
    Tian, Jian-ming
    ABDOMINAL IMAGING, 2008, 33 (04): : 463 - 468